Evaluation of silica monoliths in affinity microcolumns for high-throughput analysis of drug-protein interactions

Michelle J. Yoo, David S. Hage

Research output: Contribution to journalArticle

34 Citations (Scopus)

Abstract

Silica monoliths in affinity microcolumns were tested for the high-throughput analysis of drug-protein interactions. HSA was used as a model protein for this work, while carbamazepine and R-warfarin were used as model analytes. A comparison of HSA silica monoliths of various lengths indicated columns as short as 1 to 3 mm could be used to provide reproducible estimates of retention factors or plate heights. Benefits of using smaller columns for this work included the lower retention times and lower back pressures that could be obtained versus traditional HPLC affinity columns, as well as the smaller amount of protein that is required for column preparation. One disadvantage of decreasing column length was the lower precision that resulted in retention factor and plate height measurements. A comparison was also made between microcolumns containing silica particles versus silica monoliths. It was demonstrated with R-warfarin that supports could be used in HSA microcolumns for the determination of retention factors or plate heights. However, the higher efficiency of the silica monolith made this the preferred support for work at higher flow rates or when a larger number of plates are needed during the rapid analysis of drug-protein interactions.

Original languageEnglish (US)
Pages (from-to)2776-2785
Number of pages10
JournalJournal of Separation Science
Volume32
Issue number15-16
DOIs
StatePublished - Dec 1 2009

Fingerprint

Silicon Dioxide
Silica
Throughput
Proteins
Pharmaceutical Preparations
Warfarin
Carbamazepine
Flow rate

Keywords

  • Affinity chromatography
  • Drug- protein binding
  • Human serum albumin
  • Silica monolith

ASJC Scopus subject areas

  • Analytical Chemistry
  • Filtration and Separation

Cite this

Evaluation of silica monoliths in affinity microcolumns for high-throughput analysis of drug-protein interactions. / Yoo, Michelle J.; Hage, David S.

In: Journal of Separation Science, Vol. 32, No. 15-16, 01.12.2009, p. 2776-2785.

Research output: Contribution to journalArticle

@article{1cf0b8ec55ff4bf182a12abc5d62207e,
title = "Evaluation of silica monoliths in affinity microcolumns for high-throughput analysis of drug-protein interactions",
abstract = "Silica monoliths in affinity microcolumns were tested for the high-throughput analysis of drug-protein interactions. HSA was used as a model protein for this work, while carbamazepine and R-warfarin were used as model analytes. A comparison of HSA silica monoliths of various lengths indicated columns as short as 1 to 3 mm could be used to provide reproducible estimates of retention factors or plate heights. Benefits of using smaller columns for this work included the lower retention times and lower back pressures that could be obtained versus traditional HPLC affinity columns, as well as the smaller amount of protein that is required for column preparation. One disadvantage of decreasing column length was the lower precision that resulted in retention factor and plate height measurements. A comparison was also made between microcolumns containing silica particles versus silica monoliths. It was demonstrated with R-warfarin that supports could be used in HSA microcolumns for the determination of retention factors or plate heights. However, the higher efficiency of the silica monolith made this the preferred support for work at higher flow rates or when a larger number of plates are needed during the rapid analysis of drug-protein interactions.",
keywords = "Affinity chromatography, Drug- protein binding, Human serum albumin, Silica monolith",
author = "Yoo, {Michelle J.} and Hage, {David S.}",
year = "2009",
month = "12",
day = "1",
doi = "10.1002/jssc.200900346",
language = "English (US)",
volume = "32",
pages = "2776--2785",
journal = "Journal of Separation Science",
issn = "1615-9306",
publisher = "Wiley-VCH Verlag",
number = "15-16",

}

TY - JOUR

T1 - Evaluation of silica monoliths in affinity microcolumns for high-throughput analysis of drug-protein interactions

AU - Yoo, Michelle J.

AU - Hage, David S.

PY - 2009/12/1

Y1 - 2009/12/1

N2 - Silica monoliths in affinity microcolumns were tested for the high-throughput analysis of drug-protein interactions. HSA was used as a model protein for this work, while carbamazepine and R-warfarin were used as model analytes. A comparison of HSA silica monoliths of various lengths indicated columns as short as 1 to 3 mm could be used to provide reproducible estimates of retention factors or plate heights. Benefits of using smaller columns for this work included the lower retention times and lower back pressures that could be obtained versus traditional HPLC affinity columns, as well as the smaller amount of protein that is required for column preparation. One disadvantage of decreasing column length was the lower precision that resulted in retention factor and plate height measurements. A comparison was also made between microcolumns containing silica particles versus silica monoliths. It was demonstrated with R-warfarin that supports could be used in HSA microcolumns for the determination of retention factors or plate heights. However, the higher efficiency of the silica monolith made this the preferred support for work at higher flow rates or when a larger number of plates are needed during the rapid analysis of drug-protein interactions.

AB - Silica monoliths in affinity microcolumns were tested for the high-throughput analysis of drug-protein interactions. HSA was used as a model protein for this work, while carbamazepine and R-warfarin were used as model analytes. A comparison of HSA silica monoliths of various lengths indicated columns as short as 1 to 3 mm could be used to provide reproducible estimates of retention factors or plate heights. Benefits of using smaller columns for this work included the lower retention times and lower back pressures that could be obtained versus traditional HPLC affinity columns, as well as the smaller amount of protein that is required for column preparation. One disadvantage of decreasing column length was the lower precision that resulted in retention factor and plate height measurements. A comparison was also made between microcolumns containing silica particles versus silica monoliths. It was demonstrated with R-warfarin that supports could be used in HSA microcolumns for the determination of retention factors or plate heights. However, the higher efficiency of the silica monolith made this the preferred support for work at higher flow rates or when a larger number of plates are needed during the rapid analysis of drug-protein interactions.

KW - Affinity chromatography

KW - Drug- protein binding

KW - Human serum albumin

KW - Silica monolith

UR - http://www.scopus.com/inward/record.url?scp=70350520907&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=70350520907&partnerID=8YFLogxK

U2 - 10.1002/jssc.200900346

DO - 10.1002/jssc.200900346

M3 - Article

C2 - 19630007

AN - SCOPUS:70350520907

VL - 32

SP - 2776

EP - 2785

JO - Journal of Separation Science

JF - Journal of Separation Science

SN - 1615-9306

IS - 15-16

ER -