Evaluation of real time PCR assays for the detection and enumeration of enterohemorrhagic Escherichia coli directly from cattle feces

Brandon E Luedtke, James L. Bono, Joseph M. Bosilevac

Research output: Contribution to journalArticle

23 Citations (Scopus)

Abstract

Shiga toxin-producing Escherichia coli are a growing concern in the area of food safety, and the United States Department of Agriculture Food Safety and Inspection Service has identified the serotypes O26, O45, O103, O111, O121, O145, and O157 as adulterants in certain types of raw beef. The most relevant to human disease are the enterohemorrhagic E. coli (EHEC) strains that possess intimin (eae), Shiga toxin 1 and/or 2 (stx1-2), and in most cases the conserved pO157 or pO157 like virulence plasmid. Contamination of raw beef with EHEC is likely to occur via the transfer of cattle feces on hides to the carcass. To detect EHEC directly from cattle feces, we evaluated the utility of a multiplex real time PCR assay that targets the EHEC associated gene target ecf1 in combination with eae and stx1-2. Our assay had an increased sensitivity and provided a reliable limit of detection (LOD) of 1.25×103colony-forming unitspermL (CFUs/mL) in an EHEC spiked fecal background. In addition, we evaluated the use of a duplex qPCR assay using ecf1 for the enumeration of total EHEC directly from cattle feces. The reliable limit of quantification (LOQ) was determined to be 1.25×103CFUs/mL. Our assay requires minimal sample processing and provides LOD and LOQ of EHEC directly from cattle feces that are the lowest reported. The application of this assay towards the identification of cattle shedding EHEC at a level above 1.25×103CFUs/mL could be a first line of defense in identifying cattle shedding these pathogens.

Original languageEnglish (US)
Pages (from-to)72-79
Number of pages8
JournalJournal of Microbiological Methods
Volume105
DOIs
StatePublished - Jan 1 2014

Fingerprint

Enterohemorrhagic Escherichia coli
Feces
Real-Time Polymerase Chain Reaction
Shiga Toxin 1
Shiga Toxin 2
Food Safety
Limit of Detection
Food Inspection
Shiga-Toxigenic Escherichia coli
United States Department of Agriculture
Multiplex Polymerase Chain Reaction
Virulence
Plasmids

Keywords

  • Enterohemorrhagic E. coli
  • Limit of detection
  • Limit of quantification
  • Multiplex qPCR
  • Non-O157 Shiga toxin-producing E. coli

ASJC Scopus subject areas

  • Microbiology
  • Molecular Biology
  • Microbiology (medical)

Cite this

Evaluation of real time PCR assays for the detection and enumeration of enterohemorrhagic Escherichia coli directly from cattle feces. / Luedtke, Brandon E; Bono, James L.; Bosilevac, Joseph M.

In: Journal of Microbiological Methods, Vol. 105, 01.01.2014, p. 72-79.

Research output: Contribution to journalArticle

@article{e8ed2dafb8a64f50880711c69cee5196,
title = "Evaluation of real time PCR assays for the detection and enumeration of enterohemorrhagic Escherichia coli directly from cattle feces",
abstract = "Shiga toxin-producing Escherichia coli are a growing concern in the area of food safety, and the United States Department of Agriculture Food Safety and Inspection Service has identified the serotypes O26, O45, O103, O111, O121, O145, and O157 as adulterants in certain types of raw beef. The most relevant to human disease are the enterohemorrhagic E. coli (EHEC) strains that possess intimin (eae), Shiga toxin 1 and/or 2 (stx1-2), and in most cases the conserved pO157 or pO157 like virulence plasmid. Contamination of raw beef with EHEC is likely to occur via the transfer of cattle feces on hides to the carcass. To detect EHEC directly from cattle feces, we evaluated the utility of a multiplex real time PCR assay that targets the EHEC associated gene target ecf1 in combination with eae and stx1-2. Our assay had an increased sensitivity and provided a reliable limit of detection (LOD) of 1.25×103colony-forming unitspermL (CFUs/mL) in an EHEC spiked fecal background. In addition, we evaluated the use of a duplex qPCR assay using ecf1 for the enumeration of total EHEC directly from cattle feces. The reliable limit of quantification (LOQ) was determined to be 1.25×103CFUs/mL. Our assay requires minimal sample processing and provides LOD and LOQ of EHEC directly from cattle feces that are the lowest reported. The application of this assay towards the identification of cattle shedding EHEC at a level above 1.25×103CFUs/mL could be a first line of defense in identifying cattle shedding these pathogens.",
keywords = "Enterohemorrhagic E. coli, Limit of detection, Limit of quantification, Multiplex qPCR, Non-O157 Shiga toxin-producing E. coli",
author = "Luedtke, {Brandon E} and Bono, {James L.} and Bosilevac, {Joseph M.}",
year = "2014",
month = "1",
day = "1",
doi = "10.1016/j.mimet.2014.07.015",
language = "English (US)",
volume = "105",
pages = "72--79",
journal = "Journal of Microbiological Methods",
issn = "0167-7012",
publisher = "Elsevier",

}

TY - JOUR

T1 - Evaluation of real time PCR assays for the detection and enumeration of enterohemorrhagic Escherichia coli directly from cattle feces

AU - Luedtke, Brandon E

AU - Bono, James L.

AU - Bosilevac, Joseph M.

PY - 2014/1/1

Y1 - 2014/1/1

N2 - Shiga toxin-producing Escherichia coli are a growing concern in the area of food safety, and the United States Department of Agriculture Food Safety and Inspection Service has identified the serotypes O26, O45, O103, O111, O121, O145, and O157 as adulterants in certain types of raw beef. The most relevant to human disease are the enterohemorrhagic E. coli (EHEC) strains that possess intimin (eae), Shiga toxin 1 and/or 2 (stx1-2), and in most cases the conserved pO157 or pO157 like virulence plasmid. Contamination of raw beef with EHEC is likely to occur via the transfer of cattle feces on hides to the carcass. To detect EHEC directly from cattle feces, we evaluated the utility of a multiplex real time PCR assay that targets the EHEC associated gene target ecf1 in combination with eae and stx1-2. Our assay had an increased sensitivity and provided a reliable limit of detection (LOD) of 1.25×103colony-forming unitspermL (CFUs/mL) in an EHEC spiked fecal background. In addition, we evaluated the use of a duplex qPCR assay using ecf1 for the enumeration of total EHEC directly from cattle feces. The reliable limit of quantification (LOQ) was determined to be 1.25×103CFUs/mL. Our assay requires minimal sample processing and provides LOD and LOQ of EHEC directly from cattle feces that are the lowest reported. The application of this assay towards the identification of cattle shedding EHEC at a level above 1.25×103CFUs/mL could be a first line of defense in identifying cattle shedding these pathogens.

AB - Shiga toxin-producing Escherichia coli are a growing concern in the area of food safety, and the United States Department of Agriculture Food Safety and Inspection Service has identified the serotypes O26, O45, O103, O111, O121, O145, and O157 as adulterants in certain types of raw beef. The most relevant to human disease are the enterohemorrhagic E. coli (EHEC) strains that possess intimin (eae), Shiga toxin 1 and/or 2 (stx1-2), and in most cases the conserved pO157 or pO157 like virulence plasmid. Contamination of raw beef with EHEC is likely to occur via the transfer of cattle feces on hides to the carcass. To detect EHEC directly from cattle feces, we evaluated the utility of a multiplex real time PCR assay that targets the EHEC associated gene target ecf1 in combination with eae and stx1-2. Our assay had an increased sensitivity and provided a reliable limit of detection (LOD) of 1.25×103colony-forming unitspermL (CFUs/mL) in an EHEC spiked fecal background. In addition, we evaluated the use of a duplex qPCR assay using ecf1 for the enumeration of total EHEC directly from cattle feces. The reliable limit of quantification (LOQ) was determined to be 1.25×103CFUs/mL. Our assay requires minimal sample processing and provides LOD and LOQ of EHEC directly from cattle feces that are the lowest reported. The application of this assay towards the identification of cattle shedding EHEC at a level above 1.25×103CFUs/mL could be a first line of defense in identifying cattle shedding these pathogens.

KW - Enterohemorrhagic E. coli

KW - Limit of detection

KW - Limit of quantification

KW - Multiplex qPCR

KW - Non-O157 Shiga toxin-producing E. coli

UR - http://www.scopus.com/inward/record.url?scp=84905216517&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84905216517&partnerID=8YFLogxK

U2 - 10.1016/j.mimet.2014.07.015

DO - 10.1016/j.mimet.2014.07.015

M3 - Article

VL - 105

SP - 72

EP - 79

JO - Journal of Microbiological Methods

JF - Journal of Microbiological Methods

SN - 0167-7012

ER -