Évaluation des modèles de débit massique pour un détendeur thermostatique en boîte grise

Translated title of the contribution: Evaluation of gray box thermostatic expansion valve mass flow models

Alireza Behfar, David P Yuill

Research output: Contribution to journalArticle

Abstract

Thermostatic expansion valves (TXVs) are widely used in air-conditioning and commercial refrigeration systems. Accurate predictions of the refrigerant mass flow rate across a refrigeration cycle are desired in many engineering processes and applications such as a computer simulation model, for control purposes, or for fault detection and diagnostics (FDD). Several researchers have developed mass flow models for TXVs. This paper reviews and analyzes four gray-box TXV mass flow models in the literature and evaluates and compares their performance. Three of the models were developed for air-conditioners, but in the current work their applicability to refrigeration system modeling is assessed, with the use of normal and faulted laboratory data from a commercial walk-in cooler and a freezer. Model regression parameters are calculated during the training process with the use of parameter estimation techniques and a training dataset. The models are then used to predict the mass flow rates for several validation data points. Each of the models is found to perform well for the majority of the data points for the freezer, typically with errors below 10%, but application of the models to the cooler's dataset resulted in relatively large errors. The source of the model deviations includes the difficulty associated with the calculation of the TXV diaphragm force and the thermodynamic states of a two-phase refrigerant at the inlet of the valve. The presence of a liquid line receiver, which are common in refrigeration equipment, appears to cause some model deviation.

Original languageFrench
Pages (from-to)161-168
Number of pages8
JournalInternational Journal of Refrigeration
Volume96
DOIs
StatePublished - Dec 2018

Fingerprint

Refrigeration
Refrigerants
Commercial refrigeration
Flow rate
Diaphragms
Fault detection
Air conditioning
Parameter estimation
Thermodynamics
Computer simulation
Liquids
Air

Keywords

  • Gray-box
  • Mass flow rate
  • Regression parameters
  • TXV models

ASJC Scopus subject areas

  • Building and Construction
  • Mechanical Engineering

Cite this

Évaluation des modèles de débit massique pour un détendeur thermostatique en boîte grise. / Behfar, Alireza; Yuill, David P.

In: International Journal of Refrigeration, Vol. 96, 12.2018, p. 161-168.

Research output: Contribution to journalArticle

@article{ca842d5478e445bbb23f57f78a53716f,
title = "{\'E}valuation des mod{\`e}les de d{\'e}bit massique pour un d{\'e}tendeur thermostatique en bo{\^i}te grise",
abstract = "Thermostatic expansion valves (TXVs) are widely used in air-conditioning and commercial refrigeration systems. Accurate predictions of the refrigerant mass flow rate across a refrigeration cycle are desired in many engineering processes and applications such as a computer simulation model, for control purposes, or for fault detection and diagnostics (FDD). Several researchers have developed mass flow models for TXVs. This paper reviews and analyzes four gray-box TXV mass flow models in the literature and evaluates and compares their performance. Three of the models were developed for air-conditioners, but in the current work their applicability to refrigeration system modeling is assessed, with the use of normal and faulted laboratory data from a commercial walk-in cooler and a freezer. Model regression parameters are calculated during the training process with the use of parameter estimation techniques and a training dataset. The models are then used to predict the mass flow rates for several validation data points. Each of the models is found to perform well for the majority of the data points for the freezer, typically with errors below 10{\%}, but application of the models to the cooler's dataset resulted in relatively large errors. The source of the model deviations includes the difficulty associated with the calculation of the TXV diaphragm force and the thermodynamic states of a two-phase refrigerant at the inlet of the valve. The presence of a liquid line receiver, which are common in refrigeration equipment, appears to cause some model deviation.",
keywords = "Gray-box, Mass flow rate, Regression parameters, TXV models",
author = "Alireza Behfar and Yuill, {David P}",
year = "2018",
month = "12",
doi = "10.1016/j.ijrefrig.2018.08.008",
language = "French",
volume = "96",
pages = "161--168",
journal = "International Journal of Refrigeration",
issn = "0140-7007",
publisher = "Elsevier Limited",

}

TY - JOUR

T1 - Évaluation des modèles de débit massique pour un détendeur thermostatique en boîte grise

AU - Behfar, Alireza

AU - Yuill, David P

PY - 2018/12

Y1 - 2018/12

N2 - Thermostatic expansion valves (TXVs) are widely used in air-conditioning and commercial refrigeration systems. Accurate predictions of the refrigerant mass flow rate across a refrigeration cycle are desired in many engineering processes and applications such as a computer simulation model, for control purposes, or for fault detection and diagnostics (FDD). Several researchers have developed mass flow models for TXVs. This paper reviews and analyzes four gray-box TXV mass flow models in the literature and evaluates and compares their performance. Three of the models were developed for air-conditioners, but in the current work their applicability to refrigeration system modeling is assessed, with the use of normal and faulted laboratory data from a commercial walk-in cooler and a freezer. Model regression parameters are calculated during the training process with the use of parameter estimation techniques and a training dataset. The models are then used to predict the mass flow rates for several validation data points. Each of the models is found to perform well for the majority of the data points for the freezer, typically with errors below 10%, but application of the models to the cooler's dataset resulted in relatively large errors. The source of the model deviations includes the difficulty associated with the calculation of the TXV diaphragm force and the thermodynamic states of a two-phase refrigerant at the inlet of the valve. The presence of a liquid line receiver, which are common in refrigeration equipment, appears to cause some model deviation.

AB - Thermostatic expansion valves (TXVs) are widely used in air-conditioning and commercial refrigeration systems. Accurate predictions of the refrigerant mass flow rate across a refrigeration cycle are desired in many engineering processes and applications such as a computer simulation model, for control purposes, or for fault detection and diagnostics (FDD). Several researchers have developed mass flow models for TXVs. This paper reviews and analyzes four gray-box TXV mass flow models in the literature and evaluates and compares their performance. Three of the models were developed for air-conditioners, but in the current work their applicability to refrigeration system modeling is assessed, with the use of normal and faulted laboratory data from a commercial walk-in cooler and a freezer. Model regression parameters are calculated during the training process with the use of parameter estimation techniques and a training dataset. The models are then used to predict the mass flow rates for several validation data points. Each of the models is found to perform well for the majority of the data points for the freezer, typically with errors below 10%, but application of the models to the cooler's dataset resulted in relatively large errors. The source of the model deviations includes the difficulty associated with the calculation of the TXV diaphragm force and the thermodynamic states of a two-phase refrigerant at the inlet of the valve. The presence of a liquid line receiver, which are common in refrigeration equipment, appears to cause some model deviation.

KW - Gray-box

KW - Mass flow rate

KW - Regression parameters

KW - TXV models

UR - http://www.scopus.com/inward/record.url?scp=85055563791&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85055563791&partnerID=8YFLogxK

U2 - 10.1016/j.ijrefrig.2018.08.008

DO - 10.1016/j.ijrefrig.2018.08.008

M3 - Article

AN - SCOPUS:85055563791

VL - 96

SP - 161

EP - 168

JO - International Journal of Refrigeration

JF - International Journal of Refrigeration

SN - 0140-7007

ER -