Evaluation of deformable image registration and a motion model in CT images with limited features

F. Liu, Y. Hu, Q. Zhang, R. Kincaid, K. A. Goodman, G. S. Mageras

Research output: Contribution to journalArticle

28 Citations (Scopus)

Abstract

Deformable image registration (DIR) is increasingly used in radiotherapy applications and provides the basis for a previously described model of patient-specific respiratory motion. We examine the accuracy of a DIR algorithm and a motion model with respiration-correlated CT (RCCT) images of software phantom with known displacement fields, physical deformable abdominal phantom with implanted fiducials in the liver and small liver structures in patient images. The motion model is derived from a principal component analysis that relates volumetric deformations with the motion of the diaphragm or fiducials in the RCCT. Patient data analysis compares DIR with rigid registration as ground truth: the mean ± standard deviation 3D discrepancy of liver structure centroid positions is 2.0 ± 2.2 mm. DIR discrepancy in the software phantom is 3.8 ± 2.0 mm in lung and 3.7 ± 1.8 mm in abdomen; discrepancies near the chest wall are larger than indicated by image feature matching. Marker's 3D discrepancy in the physical phantom is 3.6 ± 2.8 mm. The results indicate that visible features in the images are important for guiding the DIR algorithm. Motion model accuracy is comparable to DIR, indicating that two principal components are sufficient to describe DIR-derived deformation in these datasets.

Original languageEnglish (US)
Pages (from-to)2539-2554
Number of pages16
JournalPhysics in medicine and biology
Volume57
Issue number9
DOIs
StatePublished - May 7 2012

Fingerprint

Liver
Respiration
Software
Fiducial Markers
Thoracic Wall
Diaphragm
Principal Component Analysis
Abdomen
Radiotherapy
Lung
Datasets

ASJC Scopus subject areas

  • Radiological and Ultrasound Technology
  • Radiology Nuclear Medicine and imaging

Cite this

Evaluation of deformable image registration and a motion model in CT images with limited features. / Liu, F.; Hu, Y.; Zhang, Q.; Kincaid, R.; Goodman, K. A.; Mageras, G. S.

In: Physics in medicine and biology, Vol. 57, No. 9, 07.05.2012, p. 2539-2554.

Research output: Contribution to journalArticle

Liu, F. ; Hu, Y. ; Zhang, Q. ; Kincaid, R. ; Goodman, K. A. ; Mageras, G. S. / Evaluation of deformable image registration and a motion model in CT images with limited features. In: Physics in medicine and biology. 2012 ; Vol. 57, No. 9. pp. 2539-2554.
@article{ce0dfa8299194143b68516e56f20ea8e,
title = "Evaluation of deformable image registration and a motion model in CT images with limited features",
abstract = "Deformable image registration (DIR) is increasingly used in radiotherapy applications and provides the basis for a previously described model of patient-specific respiratory motion. We examine the accuracy of a DIR algorithm and a motion model with respiration-correlated CT (RCCT) images of software phantom with known displacement fields, physical deformable abdominal phantom with implanted fiducials in the liver and small liver structures in patient images. The motion model is derived from a principal component analysis that relates volumetric deformations with the motion of the diaphragm or fiducials in the RCCT. Patient data analysis compares DIR with rigid registration as ground truth: the mean ± standard deviation 3D discrepancy of liver structure centroid positions is 2.0 ± 2.2 mm. DIR discrepancy in the software phantom is 3.8 ± 2.0 mm in lung and 3.7 ± 1.8 mm in abdomen; discrepancies near the chest wall are larger than indicated by image feature matching. Marker's 3D discrepancy in the physical phantom is 3.6 ± 2.8 mm. The results indicate that visible features in the images are important for guiding the DIR algorithm. Motion model accuracy is comparable to DIR, indicating that two principal components are sufficient to describe DIR-derived deformation in these datasets.",
author = "F. Liu and Y. Hu and Q. Zhang and R. Kincaid and Goodman, {K. A.} and Mageras, {G. S.}",
year = "2012",
month = "5",
day = "7",
doi = "10.1088/0031-9155/57/9/2539",
language = "English (US)",
volume = "57",
pages = "2539--2554",
journal = "Physics in Medicine and Biology",
issn = "0031-9155",
publisher = "IOP Publishing Ltd.",
number = "9",

}

TY - JOUR

T1 - Evaluation of deformable image registration and a motion model in CT images with limited features

AU - Liu, F.

AU - Hu, Y.

AU - Zhang, Q.

AU - Kincaid, R.

AU - Goodman, K. A.

AU - Mageras, G. S.

PY - 2012/5/7

Y1 - 2012/5/7

N2 - Deformable image registration (DIR) is increasingly used in radiotherapy applications and provides the basis for a previously described model of patient-specific respiratory motion. We examine the accuracy of a DIR algorithm and a motion model with respiration-correlated CT (RCCT) images of software phantom with known displacement fields, physical deformable abdominal phantom with implanted fiducials in the liver and small liver structures in patient images. The motion model is derived from a principal component analysis that relates volumetric deformations with the motion of the diaphragm or fiducials in the RCCT. Patient data analysis compares DIR with rigid registration as ground truth: the mean ± standard deviation 3D discrepancy of liver structure centroid positions is 2.0 ± 2.2 mm. DIR discrepancy in the software phantom is 3.8 ± 2.0 mm in lung and 3.7 ± 1.8 mm in abdomen; discrepancies near the chest wall are larger than indicated by image feature matching. Marker's 3D discrepancy in the physical phantom is 3.6 ± 2.8 mm. The results indicate that visible features in the images are important for guiding the DIR algorithm. Motion model accuracy is comparable to DIR, indicating that two principal components are sufficient to describe DIR-derived deformation in these datasets.

AB - Deformable image registration (DIR) is increasingly used in radiotherapy applications and provides the basis for a previously described model of patient-specific respiratory motion. We examine the accuracy of a DIR algorithm and a motion model with respiration-correlated CT (RCCT) images of software phantom with known displacement fields, physical deformable abdominal phantom with implanted fiducials in the liver and small liver structures in patient images. The motion model is derived from a principal component analysis that relates volumetric deformations with the motion of the diaphragm or fiducials in the RCCT. Patient data analysis compares DIR with rigid registration as ground truth: the mean ± standard deviation 3D discrepancy of liver structure centroid positions is 2.0 ± 2.2 mm. DIR discrepancy in the software phantom is 3.8 ± 2.0 mm in lung and 3.7 ± 1.8 mm in abdomen; discrepancies near the chest wall are larger than indicated by image feature matching. Marker's 3D discrepancy in the physical phantom is 3.6 ± 2.8 mm. The results indicate that visible features in the images are important for guiding the DIR algorithm. Motion model accuracy is comparable to DIR, indicating that two principal components are sufficient to describe DIR-derived deformation in these datasets.

UR - http://www.scopus.com/inward/record.url?scp=84859595128&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84859595128&partnerID=8YFLogxK

U2 - 10.1088/0031-9155/57/9/2539

DO - 10.1088/0031-9155/57/9/2539

M3 - Article

C2 - 22491010

AN - SCOPUS:84859595128

VL - 57

SP - 2539

EP - 2554

JO - Physics in Medicine and Biology

JF - Physics in Medicine and Biology

SN - 0031-9155

IS - 9

ER -