Evaluating anisotropic properties in the porcine temporomandibular joint disc using nanoindentation

P. A. Yuya, E. K. Amborn, Mark W Beatty, Joseph A Turner

Research output: Contribution to journalArticle

13 Citations (Scopus)

Abstract

The objective of this study was to determine the viscoelastic properties present within the intermediate zone of the porcine temporomandibular joint (TMJ) disc using nanoindentation. A 50-μm conospherical indenter tip using a displacement-controlled ramp function with a 600 nm/s loading and unloading rate, a 3000-nm peak displacement with a holding period of 30 s was used to indent the samples. Experimental load-relaxation tests were performed on the TMJ disc to determine the response in three different directions; the mediolateral, anteroposterior, and articular surface directions. The experimental data were analyzed using a generalized Maxwell model to obtain values for short- and long-time relaxation modulus and of material time constants. The short time relaxation modulus EI values were 180.92, 64.99, and 487.77 kPa for testing done on the articular surface, mediolateral, and anteroposterior directions, respectively. Corresponding values for the long-time relaxation modulus E∞ were 45.9, 14.97, and 133.5 kPa. The method confirmed anisotropy present within the central intermediate zone of the porcine TMJ disc due to the directional orientation of the collagen fibers.

Original languageEnglish (US)
Pages (from-to)2428-2437
Number of pages10
JournalAnnals of biomedical engineering
Volume38
Issue number7
DOIs
StatePublished - Jul 1 2010

Fingerprint

Nanoindentation
Relaxation time
Unloading
Collagen
Anisotropy
Fibers
Testing
Temporomandibular Joint

Keywords

  • Fibrocartilage
  • Hydration
  • Microscale
  • Relaxation modulus
  • Viscoelasticity

ASJC Scopus subject areas

  • Biomedical Engineering

Cite this

Evaluating anisotropic properties in the porcine temporomandibular joint disc using nanoindentation. / Yuya, P. A.; Amborn, E. K.; Beatty, Mark W; Turner, Joseph A.

In: Annals of biomedical engineering, Vol. 38, No. 7, 01.07.2010, p. 2428-2437.

Research output: Contribution to journalArticle

@article{07967a166da84960aea09f01ab2e3c60,
title = "Evaluating anisotropic properties in the porcine temporomandibular joint disc using nanoindentation",
abstract = "The objective of this study was to determine the viscoelastic properties present within the intermediate zone of the porcine temporomandibular joint (TMJ) disc using nanoindentation. A 50-μm conospherical indenter tip using a displacement-controlled ramp function with a 600 nm/s loading and unloading rate, a 3000-nm peak displacement with a holding period of 30 s was used to indent the samples. Experimental load-relaxation tests were performed on the TMJ disc to determine the response in three different directions; the mediolateral, anteroposterior, and articular surface directions. The experimental data were analyzed using a generalized Maxwell model to obtain values for short- and long-time relaxation modulus and of material time constants. The short time relaxation modulus EI values were 180.92, 64.99, and 487.77 kPa for testing done on the articular surface, mediolateral, and anteroposterior directions, respectively. Corresponding values for the long-time relaxation modulus E∞ were 45.9, 14.97, and 133.5 kPa. The method confirmed anisotropy present within the central intermediate zone of the porcine TMJ disc due to the directional orientation of the collagen fibers.",
keywords = "Fibrocartilage, Hydration, Microscale, Relaxation modulus, Viscoelasticity",
author = "Yuya, {P. A.} and Amborn, {E. K.} and Beatty, {Mark W} and Turner, {Joseph A}",
year = "2010",
month = "7",
day = "1",
doi = "10.1007/s10439-010-9967-8",
language = "English (US)",
volume = "38",
pages = "2428--2437",
journal = "Annals of Biomedical Engineering",
issn = "0090-6964",
publisher = "Springer Netherlands",
number = "7",

}

TY - JOUR

T1 - Evaluating anisotropic properties in the porcine temporomandibular joint disc using nanoindentation

AU - Yuya, P. A.

AU - Amborn, E. K.

AU - Beatty, Mark W

AU - Turner, Joseph A

PY - 2010/7/1

Y1 - 2010/7/1

N2 - The objective of this study was to determine the viscoelastic properties present within the intermediate zone of the porcine temporomandibular joint (TMJ) disc using nanoindentation. A 50-μm conospherical indenter tip using a displacement-controlled ramp function with a 600 nm/s loading and unloading rate, a 3000-nm peak displacement with a holding period of 30 s was used to indent the samples. Experimental load-relaxation tests were performed on the TMJ disc to determine the response in three different directions; the mediolateral, anteroposterior, and articular surface directions. The experimental data were analyzed using a generalized Maxwell model to obtain values for short- and long-time relaxation modulus and of material time constants. The short time relaxation modulus EI values were 180.92, 64.99, and 487.77 kPa for testing done on the articular surface, mediolateral, and anteroposterior directions, respectively. Corresponding values for the long-time relaxation modulus E∞ were 45.9, 14.97, and 133.5 kPa. The method confirmed anisotropy present within the central intermediate zone of the porcine TMJ disc due to the directional orientation of the collagen fibers.

AB - The objective of this study was to determine the viscoelastic properties present within the intermediate zone of the porcine temporomandibular joint (TMJ) disc using nanoindentation. A 50-μm conospherical indenter tip using a displacement-controlled ramp function with a 600 nm/s loading and unloading rate, a 3000-nm peak displacement with a holding period of 30 s was used to indent the samples. Experimental load-relaxation tests were performed on the TMJ disc to determine the response in three different directions; the mediolateral, anteroposterior, and articular surface directions. The experimental data were analyzed using a generalized Maxwell model to obtain values for short- and long-time relaxation modulus and of material time constants. The short time relaxation modulus EI values were 180.92, 64.99, and 487.77 kPa for testing done on the articular surface, mediolateral, and anteroposterior directions, respectively. Corresponding values for the long-time relaxation modulus E∞ were 45.9, 14.97, and 133.5 kPa. The method confirmed anisotropy present within the central intermediate zone of the porcine TMJ disc due to the directional orientation of the collagen fibers.

KW - Fibrocartilage

KW - Hydration

KW - Microscale

KW - Relaxation modulus

KW - Viscoelasticity

UR - http://www.scopus.com/inward/record.url?scp=77954657902&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=77954657902&partnerID=8YFLogxK

U2 - 10.1007/s10439-010-9967-8

DO - 10.1007/s10439-010-9967-8

M3 - Article

C2 - 20195763

AN - SCOPUS:77954657902

VL - 38

SP - 2428

EP - 2437

JO - Annals of Biomedical Engineering

JF - Annals of Biomedical Engineering

SN - 0090-6964

IS - 7

ER -