Energy expenditure and gait characteristics of a bilateral amputee walking with C-leg prostheses compared with stubby and conventional articulating prostheses

Jacquelin Perry, Judith Burnfield, Craig J. Newsam, Phil Conley

Research output: Contribution to journalArticle

48 Citations (Scopus)

Abstract

Perry J, Burnfield JM, Newsam CJ, Conley P. Energy expenditure and gait characteristics of a bilateral amputee walking with C-Leg prostheses compared with stubby and conventional articulating prostheses. To compare energy cost and stride characteristics during walking with 3 different types of prostheses in a person with bilateral knee disarticulations. Single-case study. Pathokinesiology laboratory. A subject with bilateral knee disarticulations and bilateral transradial amputations secondary to meningococcemia with purpura fulminans. Not applicable. Energy cost, stride characteristics, and motion analysis. When wearing the C-Leg prostheses, the subject walked the farthest and fastest, with an overall lower rate of oxygen consumption and oxygen cost compared with walking with either of the other prostheses. Gait analysis while the patient was wearing the C-Leg prostheses revealed premature hip extension, absence of knee flexion during loading response, and a rate of swing in the referent range. Walking in a C-leg was the most efficient method of ambulation for our subject.

Original languageEnglish (US)
Pages (from-to)1711-1717
Number of pages7
JournalArchives of Physical Medicine and Rehabilitation
Volume85
Issue number10
DOIs
StatePublished - Oct 1 2004

Fingerprint

Artificial Limbs
Amputees
Gait
Energy Metabolism
Prostheses and Implants
Walking
Disarticulation
Knee
Costs and Cost Analysis
Purpura Fulminans
Amputation
Oxygen Consumption
Hip
Leg
Oxygen

Keywords

  • Artificial limbs
  • Disarticulations
  • Energy expenditure
  • Knee
  • Rehabilitation

ASJC Scopus subject areas

  • Rehabilitation

Cite this

Energy expenditure and gait characteristics of a bilateral amputee walking with C-leg prostheses compared with stubby and conventional articulating prostheses. / Perry, Jacquelin; Burnfield, Judith; Newsam, Craig J.; Conley, Phil.

In: Archives of Physical Medicine and Rehabilitation, Vol. 85, No. 10, 01.10.2004, p. 1711-1717.

Research output: Contribution to journalArticle

@article{b6a69ea2d2744ebaa2f0f411154a3da6,
title = "Energy expenditure and gait characteristics of a bilateral amputee walking with C-leg prostheses compared with stubby and conventional articulating prostheses",
abstract = "Perry J, Burnfield JM, Newsam CJ, Conley P. Energy expenditure and gait characteristics of a bilateral amputee walking with C-Leg prostheses compared with stubby and conventional articulating prostheses. To compare energy cost and stride characteristics during walking with 3 different types of prostheses in a person with bilateral knee disarticulations. Single-case study. Pathokinesiology laboratory. A subject with bilateral knee disarticulations and bilateral transradial amputations secondary to meningococcemia with purpura fulminans. Not applicable. Energy cost, stride characteristics, and motion analysis. When wearing the C-Leg prostheses, the subject walked the farthest and fastest, with an overall lower rate of oxygen consumption and oxygen cost compared with walking with either of the other prostheses. Gait analysis while the patient was wearing the C-Leg prostheses revealed premature hip extension, absence of knee flexion during loading response, and a rate of swing in the referent range. Walking in a C-leg was the most efficient method of ambulation for our subject.",
keywords = "Artificial limbs, Disarticulations, Energy expenditure, Knee, Rehabilitation",
author = "Jacquelin Perry and Judith Burnfield and Newsam, {Craig J.} and Phil Conley",
year = "2004",
month = "10",
day = "1",
doi = "10.1016/j.apmr.2004.02.028",
language = "English (US)",
volume = "85",
pages = "1711--1717",
journal = "Archives of Physical Medicine and Rehabilitation",
issn = "0003-9993",
publisher = "W.B. Saunders Ltd",
number = "10",

}

TY - JOUR

T1 - Energy expenditure and gait characteristics of a bilateral amputee walking with C-leg prostheses compared with stubby and conventional articulating prostheses

AU - Perry, Jacquelin

AU - Burnfield, Judith

AU - Newsam, Craig J.

AU - Conley, Phil

PY - 2004/10/1

Y1 - 2004/10/1

N2 - Perry J, Burnfield JM, Newsam CJ, Conley P. Energy expenditure and gait characteristics of a bilateral amputee walking with C-Leg prostheses compared with stubby and conventional articulating prostheses. To compare energy cost and stride characteristics during walking with 3 different types of prostheses in a person with bilateral knee disarticulations. Single-case study. Pathokinesiology laboratory. A subject with bilateral knee disarticulations and bilateral transradial amputations secondary to meningococcemia with purpura fulminans. Not applicable. Energy cost, stride characteristics, and motion analysis. When wearing the C-Leg prostheses, the subject walked the farthest and fastest, with an overall lower rate of oxygen consumption and oxygen cost compared with walking with either of the other prostheses. Gait analysis while the patient was wearing the C-Leg prostheses revealed premature hip extension, absence of knee flexion during loading response, and a rate of swing in the referent range. Walking in a C-leg was the most efficient method of ambulation for our subject.

AB - Perry J, Burnfield JM, Newsam CJ, Conley P. Energy expenditure and gait characteristics of a bilateral amputee walking with C-Leg prostheses compared with stubby and conventional articulating prostheses. To compare energy cost and stride characteristics during walking with 3 different types of prostheses in a person with bilateral knee disarticulations. Single-case study. Pathokinesiology laboratory. A subject with bilateral knee disarticulations and bilateral transradial amputations secondary to meningococcemia with purpura fulminans. Not applicable. Energy cost, stride characteristics, and motion analysis. When wearing the C-Leg prostheses, the subject walked the farthest and fastest, with an overall lower rate of oxygen consumption and oxygen cost compared with walking with either of the other prostheses. Gait analysis while the patient was wearing the C-Leg prostheses revealed premature hip extension, absence of knee flexion during loading response, and a rate of swing in the referent range. Walking in a C-leg was the most efficient method of ambulation for our subject.

KW - Artificial limbs

KW - Disarticulations

KW - Energy expenditure

KW - Knee

KW - Rehabilitation

UR - http://www.scopus.com/inward/record.url?scp=5344245382&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=5344245382&partnerID=8YFLogxK

U2 - 10.1016/j.apmr.2004.02.028

DO - 10.1016/j.apmr.2004.02.028

M3 - Article

VL - 85

SP - 1711

EP - 1717

JO - Archives of Physical Medicine and Rehabilitation

JF - Archives of Physical Medicine and Rehabilitation

SN - 0003-9993

IS - 10

ER -