Electromyographic Responses from the Vastus Medialis during Isometric Muscle Actions

C. M. Smith, T. J. Housh, T. Herda, J. M. Zuniga, C. L. Camic, H. C. Bergstrom, D. B. Smith, J. P. Weir, J. T. Cramer, E. C. Hill, K. C. Cochrane, N. D.M. Jenkins, R. J. Schmidt, G. Johnson

Research output: Contribution to journalArticle

4 Citations (Scopus)

Abstract

This study examined the electromyographic (EMG) responses from the vastus medialis (VM) for electrodes placed over and away from the innervation zone (IZ) during a maximal voluntary isometric contraction (MVIC) and sustained, submaximal isometric muscle action. A linear electrode array was placed on the VM to identify the IZ and muscle fiber pennation angle during an MVIC and sustained isometric muscle action at 50% MVIC. EMG amplitude and frequency parameters were determined from 7 bipolar channels of the electrode array, including over the IZ, as well as 10 mm, 20 mm and 30 mm proximal and distal to the IZ. There were no differences between the channels for the patterns of responses for EMG amplitude or mean power frequency during the sustained, submaximal isometric muscle action; however, there were differences between channels during the MVIC. The results of the present study supported the need to standardize the placement of electrodes on the VM for the assessment of EMG amplitude and mean power frequency. Based on the current findings, it is recommended that electrode placements be distal to the IZ and aligned with the muscle fiber pennation angle during MVICs, as well as sustained, submaximal isometric muscle actions.

Original languageEnglish (US)
Pages (from-to)647-652
Number of pages6
JournalInternational Journal of Sports Medicine
Volume37
Issue number8
DOIs
StatePublished - Jul 1 2016

Fingerprint

Quadriceps Muscle
Isometric Contraction
Electrodes
Muscles

Keywords

  • EMG
  • IZ
  • MVIC
  • VM
  • electrode placement
  • innervation zone

ASJC Scopus subject areas

  • Orthopedics and Sports Medicine
  • Physical Therapy, Sports Therapy and Rehabilitation

Cite this

Electromyographic Responses from the Vastus Medialis during Isometric Muscle Actions. / Smith, C. M.; Housh, T. J.; Herda, T.; Zuniga, J. M.; Camic, C. L.; Bergstrom, H. C.; Smith, D. B.; Weir, J. P.; Cramer, J. T.; Hill, E. C.; Cochrane, K. C.; Jenkins, N. D.M.; Schmidt, R. J.; Johnson, G.

In: International Journal of Sports Medicine, Vol. 37, No. 8, 01.07.2016, p. 647-652.

Research output: Contribution to journalArticle

Smith, CM, Housh, TJ, Herda, T, Zuniga, JM, Camic, CL, Bergstrom, HC, Smith, DB, Weir, JP, Cramer, JT, Hill, EC, Cochrane, KC, Jenkins, NDM, Schmidt, RJ & Johnson, G 2016, 'Electromyographic Responses from the Vastus Medialis during Isometric Muscle Actions', International Journal of Sports Medicine, vol. 37, no. 8, pp. 647-652. https://doi.org/10.1055/s-0035-1564174
Smith, C. M. ; Housh, T. J. ; Herda, T. ; Zuniga, J. M. ; Camic, C. L. ; Bergstrom, H. C. ; Smith, D. B. ; Weir, J. P. ; Cramer, J. T. ; Hill, E. C. ; Cochrane, K. C. ; Jenkins, N. D.M. ; Schmidt, R. J. ; Johnson, G. / Electromyographic Responses from the Vastus Medialis during Isometric Muscle Actions. In: International Journal of Sports Medicine. 2016 ; Vol. 37, No. 8. pp. 647-652.
@article{0d9a473c051a4bacb575aea6cebbbacc,
title = "Electromyographic Responses from the Vastus Medialis during Isometric Muscle Actions",
abstract = "This study examined the electromyographic (EMG) responses from the vastus medialis (VM) for electrodes placed over and away from the innervation zone (IZ) during a maximal voluntary isometric contraction (MVIC) and sustained, submaximal isometric muscle action. A linear electrode array was placed on the VM to identify the IZ and muscle fiber pennation angle during an MVIC and sustained isometric muscle action at 50{\%} MVIC. EMG amplitude and frequency parameters were determined from 7 bipolar channels of the electrode array, including over the IZ, as well as 10 mm, 20 mm and 30 mm proximal and distal to the IZ. There were no differences between the channels for the patterns of responses for EMG amplitude or mean power frequency during the sustained, submaximal isometric muscle action; however, there were differences between channels during the MVIC. The results of the present study supported the need to standardize the placement of electrodes on the VM for the assessment of EMG amplitude and mean power frequency. Based on the current findings, it is recommended that electrode placements be distal to the IZ and aligned with the muscle fiber pennation angle during MVICs, as well as sustained, submaximal isometric muscle actions.",
keywords = "EMG, IZ, MVIC, VM, electrode placement, innervation zone",
author = "Smith, {C. M.} and Housh, {T. J.} and T. Herda and Zuniga, {J. M.} and Camic, {C. L.} and Bergstrom, {H. C.} and Smith, {D. B.} and Weir, {J. P.} and Cramer, {J. T.} and Hill, {E. C.} and Cochrane, {K. C.} and Jenkins, {N. D.M.} and Schmidt, {R. J.} and G. Johnson",
year = "2016",
month = "7",
day = "1",
doi = "10.1055/s-0035-1564174",
language = "English (US)",
volume = "37",
pages = "647--652",
journal = "International Journal of Sports Medicine",
issn = "0172-4622",
publisher = "Georg Thieme Verlag",
number = "8",

}

TY - JOUR

T1 - Electromyographic Responses from the Vastus Medialis during Isometric Muscle Actions

AU - Smith, C. M.

AU - Housh, T. J.

AU - Herda, T.

AU - Zuniga, J. M.

AU - Camic, C. L.

AU - Bergstrom, H. C.

AU - Smith, D. B.

AU - Weir, J. P.

AU - Cramer, J. T.

AU - Hill, E. C.

AU - Cochrane, K. C.

AU - Jenkins, N. D.M.

AU - Schmidt, R. J.

AU - Johnson, G.

PY - 2016/7/1

Y1 - 2016/7/1

N2 - This study examined the electromyographic (EMG) responses from the vastus medialis (VM) for electrodes placed over and away from the innervation zone (IZ) during a maximal voluntary isometric contraction (MVIC) and sustained, submaximal isometric muscle action. A linear electrode array was placed on the VM to identify the IZ and muscle fiber pennation angle during an MVIC and sustained isometric muscle action at 50% MVIC. EMG amplitude and frequency parameters were determined from 7 bipolar channels of the electrode array, including over the IZ, as well as 10 mm, 20 mm and 30 mm proximal and distal to the IZ. There were no differences between the channels for the patterns of responses for EMG amplitude or mean power frequency during the sustained, submaximal isometric muscle action; however, there were differences between channels during the MVIC. The results of the present study supported the need to standardize the placement of electrodes on the VM for the assessment of EMG amplitude and mean power frequency. Based on the current findings, it is recommended that electrode placements be distal to the IZ and aligned with the muscle fiber pennation angle during MVICs, as well as sustained, submaximal isometric muscle actions.

AB - This study examined the electromyographic (EMG) responses from the vastus medialis (VM) for electrodes placed over and away from the innervation zone (IZ) during a maximal voluntary isometric contraction (MVIC) and sustained, submaximal isometric muscle action. A linear electrode array was placed on the VM to identify the IZ and muscle fiber pennation angle during an MVIC and sustained isometric muscle action at 50% MVIC. EMG amplitude and frequency parameters were determined from 7 bipolar channels of the electrode array, including over the IZ, as well as 10 mm, 20 mm and 30 mm proximal and distal to the IZ. There were no differences between the channels for the patterns of responses for EMG amplitude or mean power frequency during the sustained, submaximal isometric muscle action; however, there were differences between channels during the MVIC. The results of the present study supported the need to standardize the placement of electrodes on the VM for the assessment of EMG amplitude and mean power frequency. Based on the current findings, it is recommended that electrode placements be distal to the IZ and aligned with the muscle fiber pennation angle during MVICs, as well as sustained, submaximal isometric muscle actions.

KW - EMG

KW - IZ

KW - MVIC

KW - VM

KW - electrode placement

KW - innervation zone

UR - http://www.scopus.com/inward/record.url?scp=84967335336&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84967335336&partnerID=8YFLogxK

U2 - 10.1055/s-0035-1564174

DO - 10.1055/s-0035-1564174

M3 - Article

C2 - 27176892

AN - SCOPUS:84967335336

VL - 37

SP - 647

EP - 652

JO - International Journal of Sports Medicine

JF - International Journal of Sports Medicine

SN - 0172-4622

IS - 8

ER -