Effects of DNA Probe Length on the Performance of a Dynamics-based Electrochemical Hg(II) Sensor

Yao Wu, Savannah L. Baker, Rebecca Y. Lai

Research output: Contribution to journalArticle

3 Citations (Scopus)

Abstract

We investigated the effects of DNA probe length on the performance of a dynamics-based electrochemical metal ion (E-ION) Hg(II) sensor. A systematic comparison of three versions of the Hg(II) sensor fabricated using oligothymine (oligo-T) probes of different lengths (6, 12, and 18 bases) is presented here. Independent of the probe length, the sensing mechanism of the sensor remains the same. It is based on the specific interactions between Hg(II) and thymine (T), formation of the T-Hg(II)-T complexes rigidifies the methylene blue (MB)-modified oligo-T probes, resulting in a concentration-dependent reduction in the MB signal. Although there are noted differences in sensor characteristics such as the limit of detection and dynamic range, all three sensors have demonstrated to be specific and selective. Thus, depending on the specific sensor properties that are required for the analysis, a shorter or longer oligo-T probe should be employed. With further optimization, this sensor could find applications in real time detection of Hg(II) in environmental samples.

Original languageEnglish (US)
Pages (from-to)2239-2245
Number of pages7
JournalElectroanalysis
Volume29
Issue number10
DOIs
StatePublished - Oct 2017

Fingerprint

DNA Probes
DNA
Sensors
Methylene Blue
Thymine
Metal ions

Keywords

  • Electrochemical metal ion sensors
  • alternating current voltammetry
  • mercury
  • methylene blue
  • thymine

ASJC Scopus subject areas

  • Analytical Chemistry
  • Electrochemistry

Cite this

Effects of DNA Probe Length on the Performance of a Dynamics-based Electrochemical Hg(II) Sensor. / Wu, Yao; Baker, Savannah L.; Lai, Rebecca Y.

In: Electroanalysis, Vol. 29, No. 10, 10.2017, p. 2239-2245.

Research output: Contribution to journalArticle

@article{ee158c8764154dc98901ec228942995c,
title = "Effects of DNA Probe Length on the Performance of a Dynamics-based Electrochemical Hg(II) Sensor",
abstract = "We investigated the effects of DNA probe length on the performance of a dynamics-based electrochemical metal ion (E-ION) Hg(II) sensor. A systematic comparison of three versions of the Hg(II) sensor fabricated using oligothymine (oligo-T) probes of different lengths (6, 12, and 18 bases) is presented here. Independent of the probe length, the sensing mechanism of the sensor remains the same. It is based on the specific interactions between Hg(II) and thymine (T), formation of the T-Hg(II)-T complexes rigidifies the methylene blue (MB)-modified oligo-T probes, resulting in a concentration-dependent reduction in the MB signal. Although there are noted differences in sensor characteristics such as the limit of detection and dynamic range, all three sensors have demonstrated to be specific and selective. Thus, depending on the specific sensor properties that are required for the analysis, a shorter or longer oligo-T probe should be employed. With further optimization, this sensor could find applications in real time detection of Hg(II) in environmental samples.",
keywords = "Electrochemical metal ion sensors, alternating current voltammetry, mercury, methylene blue, thymine",
author = "Yao Wu and Baker, {Savannah L.} and Lai, {Rebecca Y.}",
year = "2017",
month = "10",
doi = "10.1002/elan.201700314",
language = "English (US)",
volume = "29",
pages = "2239--2245",
journal = "Electroanalysis",
issn = "1040-0397",
publisher = "Wiley-VCH Verlag",
number = "10",

}

TY - JOUR

T1 - Effects of DNA Probe Length on the Performance of a Dynamics-based Electrochemical Hg(II) Sensor

AU - Wu, Yao

AU - Baker, Savannah L.

AU - Lai, Rebecca Y.

PY - 2017/10

Y1 - 2017/10

N2 - We investigated the effects of DNA probe length on the performance of a dynamics-based electrochemical metal ion (E-ION) Hg(II) sensor. A systematic comparison of three versions of the Hg(II) sensor fabricated using oligothymine (oligo-T) probes of different lengths (6, 12, and 18 bases) is presented here. Independent of the probe length, the sensing mechanism of the sensor remains the same. It is based on the specific interactions between Hg(II) and thymine (T), formation of the T-Hg(II)-T complexes rigidifies the methylene blue (MB)-modified oligo-T probes, resulting in a concentration-dependent reduction in the MB signal. Although there are noted differences in sensor characteristics such as the limit of detection and dynamic range, all three sensors have demonstrated to be specific and selective. Thus, depending on the specific sensor properties that are required for the analysis, a shorter or longer oligo-T probe should be employed. With further optimization, this sensor could find applications in real time detection of Hg(II) in environmental samples.

AB - We investigated the effects of DNA probe length on the performance of a dynamics-based electrochemical metal ion (E-ION) Hg(II) sensor. A systematic comparison of three versions of the Hg(II) sensor fabricated using oligothymine (oligo-T) probes of different lengths (6, 12, and 18 bases) is presented here. Independent of the probe length, the sensing mechanism of the sensor remains the same. It is based on the specific interactions between Hg(II) and thymine (T), formation of the T-Hg(II)-T complexes rigidifies the methylene blue (MB)-modified oligo-T probes, resulting in a concentration-dependent reduction in the MB signal. Although there are noted differences in sensor characteristics such as the limit of detection and dynamic range, all three sensors have demonstrated to be specific and selective. Thus, depending on the specific sensor properties that are required for the analysis, a shorter or longer oligo-T probe should be employed. With further optimization, this sensor could find applications in real time detection of Hg(II) in environmental samples.

KW - Electrochemical metal ion sensors

KW - alternating current voltammetry

KW - mercury

KW - methylene blue

KW - thymine

UR - http://www.scopus.com/inward/record.url?scp=85021430941&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85021430941&partnerID=8YFLogxK

U2 - 10.1002/elan.201700314

DO - 10.1002/elan.201700314

M3 - Article

AN - SCOPUS:85021430941

VL - 29

SP - 2239

EP - 2245

JO - Electroanalysis

JF - Electroanalysis

SN - 1040-0397

IS - 10

ER -