Effect of microbubble-enhanced ultrasound on percutaneous ethanol ablation of rat walker-256 tumour

Wenhong Gao, Lu Qiao, Yuejuan Gao, Li Zhang, Dong Zhang, Juan Tu, Zheng Liu, Feng Xie

Research output: Contribution to journalArticle

1 Citation (Scopus)

Abstract

Objectives: Percutaneous ethanol ablation (PEA) is an effective method for treating small liver cancer. Microbubble-enhanced ultrasound (MEUS) can potentially promote PEA by disrupting the tumour’s circulation. In this study, treatment combining MEUS and PEA was performed to find any synergistic effects in tumour ablation. Methods: Ten rats bearing subcutaneous Walker-256 tumours were treated by MEUS combined with PEA. The other 18 tumour-bearing rats that were treated by MEUS or PEA served as the controls. MEUS was conducted by therapeutic ultrasound (TUS) and microbubble injection. TUS was operated at a frequency of 831 KHz with a pressure amplitude of 4.3 MPa. Tumour blood perfusion was assessed by contrast-enhanced ultrasound (CEUS), and the tumour necrosis rate was determined by histological examination. Results: CEUS showed that the tumour blood perfusion almost vanished in all of the MEUS-treated tumours. The contrast peak intensity dropped 84.8 % in the MEUS + PEA-treated tumours when compared to 46.3 % (p < 0.05) in the PEA-treated tumours 24 h after treatment. The tumour necrosis rate of the combination therapy was 97.50 %, which is much higher than that of the MEUS- (66.2 %) and PEA-treated (81.0 %) tumours. Conclusion: PEA combined with MEUS can induce a much more complete tumour necrosis. Key Points: • This experiment demonstrated a novel method for enhancing percutaneous ethanol ablation. • Microbubble-enhanced therapeutic ultrasound is capable of disrupting tumour circulation. • Combined therapy of MEUS and PEA can induce more complete necrosis of tumours.

Original languageEnglish (US)
Pages (from-to)3017-3025
Number of pages9
JournalEuropean Radiology
Volume26
Issue number9
DOIs
StatePublished - Sep 1 2016

Fingerprint

Walkers
Microbubbles
Ethanol
Neoplasms
Necrosis
Therapeutics
Perfusion

Keywords

  • Contrast-enhanced ultrasound
  • Microbubble-enhanced ultrasound
  • Necrosis rate
  • Percutaneous ethanol ablation
  • Walker-256 tumour

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging

Cite this

Effect of microbubble-enhanced ultrasound on percutaneous ethanol ablation of rat walker-256 tumour. / Gao, Wenhong; Qiao, Lu; Gao, Yuejuan; Zhang, Li; Zhang, Dong; Tu, Juan; Liu, Zheng; Xie, Feng.

In: European Radiology, Vol. 26, No. 9, 01.09.2016, p. 3017-3025.

Research output: Contribution to journalArticle

Gao, Wenhong ; Qiao, Lu ; Gao, Yuejuan ; Zhang, Li ; Zhang, Dong ; Tu, Juan ; Liu, Zheng ; Xie, Feng. / Effect of microbubble-enhanced ultrasound on percutaneous ethanol ablation of rat walker-256 tumour. In: European Radiology. 2016 ; Vol. 26, No. 9. pp. 3017-3025.
@article{f19774de17ab484bbea2cf8ce45d33ed,
title = "Effect of microbubble-enhanced ultrasound on percutaneous ethanol ablation of rat walker-256 tumour",
abstract = "Objectives: Percutaneous ethanol ablation (PEA) is an effective method for treating small liver cancer. Microbubble-enhanced ultrasound (MEUS) can potentially promote PEA by disrupting the tumour’s circulation. In this study, treatment combining MEUS and PEA was performed to find any synergistic effects in tumour ablation. Methods: Ten rats bearing subcutaneous Walker-256 tumours were treated by MEUS combined with PEA. The other 18 tumour-bearing rats that were treated by MEUS or PEA served as the controls. MEUS was conducted by therapeutic ultrasound (TUS) and microbubble injection. TUS was operated at a frequency of 831 KHz with a pressure amplitude of 4.3 MPa. Tumour blood perfusion was assessed by contrast-enhanced ultrasound (CEUS), and the tumour necrosis rate was determined by histological examination. Results: CEUS showed that the tumour blood perfusion almost vanished in all of the MEUS-treated tumours. The contrast peak intensity dropped 84.8 {\%} in the MEUS + PEA-treated tumours when compared to 46.3 {\%} (p < 0.05) in the PEA-treated tumours 24 h after treatment. The tumour necrosis rate of the combination therapy was 97.50 {\%}, which is much higher than that of the MEUS- (66.2 {\%}) and PEA-treated (81.0 {\%}) tumours. Conclusion: PEA combined with MEUS can induce a much more complete tumour necrosis. Key Points: • This experiment demonstrated a novel method for enhancing percutaneous ethanol ablation. • Microbubble-enhanced therapeutic ultrasound is capable of disrupting tumour circulation. • Combined therapy of MEUS and PEA can induce more complete necrosis of tumours.",
keywords = "Contrast-enhanced ultrasound, Microbubble-enhanced ultrasound, Necrosis rate, Percutaneous ethanol ablation, Walker-256 tumour",
author = "Wenhong Gao and Lu Qiao and Yuejuan Gao and Li Zhang and Dong Zhang and Juan Tu and Zheng Liu and Feng Xie",
year = "2016",
month = "9",
day = "1",
doi = "10.1007/s00330-015-4153-x",
language = "English (US)",
volume = "26",
pages = "3017--3025",
journal = "European Radiology",
issn = "0938-7994",
publisher = "Springer Verlag",
number = "9",

}

TY - JOUR

T1 - Effect of microbubble-enhanced ultrasound on percutaneous ethanol ablation of rat walker-256 tumour

AU - Gao, Wenhong

AU - Qiao, Lu

AU - Gao, Yuejuan

AU - Zhang, Li

AU - Zhang, Dong

AU - Tu, Juan

AU - Liu, Zheng

AU - Xie, Feng

PY - 2016/9/1

Y1 - 2016/9/1

N2 - Objectives: Percutaneous ethanol ablation (PEA) is an effective method for treating small liver cancer. Microbubble-enhanced ultrasound (MEUS) can potentially promote PEA by disrupting the tumour’s circulation. In this study, treatment combining MEUS and PEA was performed to find any synergistic effects in tumour ablation. Methods: Ten rats bearing subcutaneous Walker-256 tumours were treated by MEUS combined with PEA. The other 18 tumour-bearing rats that were treated by MEUS or PEA served as the controls. MEUS was conducted by therapeutic ultrasound (TUS) and microbubble injection. TUS was operated at a frequency of 831 KHz with a pressure amplitude of 4.3 MPa. Tumour blood perfusion was assessed by contrast-enhanced ultrasound (CEUS), and the tumour necrosis rate was determined by histological examination. Results: CEUS showed that the tumour blood perfusion almost vanished in all of the MEUS-treated tumours. The contrast peak intensity dropped 84.8 % in the MEUS + PEA-treated tumours when compared to 46.3 % (p < 0.05) in the PEA-treated tumours 24 h after treatment. The tumour necrosis rate of the combination therapy was 97.50 %, which is much higher than that of the MEUS- (66.2 %) and PEA-treated (81.0 %) tumours. Conclusion: PEA combined with MEUS can induce a much more complete tumour necrosis. Key Points: • This experiment demonstrated a novel method for enhancing percutaneous ethanol ablation. • Microbubble-enhanced therapeutic ultrasound is capable of disrupting tumour circulation. • Combined therapy of MEUS and PEA can induce more complete necrosis of tumours.

AB - Objectives: Percutaneous ethanol ablation (PEA) is an effective method for treating small liver cancer. Microbubble-enhanced ultrasound (MEUS) can potentially promote PEA by disrupting the tumour’s circulation. In this study, treatment combining MEUS and PEA was performed to find any synergistic effects in tumour ablation. Methods: Ten rats bearing subcutaneous Walker-256 tumours were treated by MEUS combined with PEA. The other 18 tumour-bearing rats that were treated by MEUS or PEA served as the controls. MEUS was conducted by therapeutic ultrasound (TUS) and microbubble injection. TUS was operated at a frequency of 831 KHz with a pressure amplitude of 4.3 MPa. Tumour blood perfusion was assessed by contrast-enhanced ultrasound (CEUS), and the tumour necrosis rate was determined by histological examination. Results: CEUS showed that the tumour blood perfusion almost vanished in all of the MEUS-treated tumours. The contrast peak intensity dropped 84.8 % in the MEUS + PEA-treated tumours when compared to 46.3 % (p < 0.05) in the PEA-treated tumours 24 h after treatment. The tumour necrosis rate of the combination therapy was 97.50 %, which is much higher than that of the MEUS- (66.2 %) and PEA-treated (81.0 %) tumours. Conclusion: PEA combined with MEUS can induce a much more complete tumour necrosis. Key Points: • This experiment demonstrated a novel method for enhancing percutaneous ethanol ablation. • Microbubble-enhanced therapeutic ultrasound is capable of disrupting tumour circulation. • Combined therapy of MEUS and PEA can induce more complete necrosis of tumours.

KW - Contrast-enhanced ultrasound

KW - Microbubble-enhanced ultrasound

KW - Necrosis rate

KW - Percutaneous ethanol ablation

KW - Walker-256 tumour

UR - http://www.scopus.com/inward/record.url?scp=84949957643&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84949957643&partnerID=8YFLogxK

U2 - 10.1007/s00330-015-4153-x

DO - 10.1007/s00330-015-4153-x

M3 - Article

C2 - 26676561

AN - SCOPUS:84949957643

VL - 26

SP - 3017

EP - 3025

JO - European Radiology

JF - European Radiology

SN - 0938-7994

IS - 9

ER -