Double-evoked otoacoustic emissions. II. Intermittent noise rejection, calibration and ear-canal measurements

Douglas H Keefe, Robert Ling

Research output: Contribution to journalArticle

36 Citations (Scopus)

Abstract

Measurements of double-click-evoked otoacoustics emissions (2CEOAEs) and double-chirp distortion products (2ChDPs) are reported for normal-hearing adults based upon theory presented in an earlier report [Keefe, J. Acoust. Soc. Am. 103, 3489-3498 (1998)]. The nonlinear acoustic response of a probe assembly used in ear-canal measurements is tested in a calibration cavity to compare the double-evoked (2E) technique with existing OAE techniques. The 2E technique reduces the peak distortion by approximately 30 dB relative to existing click-evoked techniques. The 2E subtraction of click responses is partially analogous to current techniques in that the linear response is eliminated, but differs in that high-frequency measurements are improved by eliminating time gating of the cochlear response, and low-frequency measurements are improved by reducing probe distortion, especially when two acoustic sources are used. Because time gating is eliminated, it is straightforward to measure the onset of a click-evoked OAE. The nonlinear coherence function is used to measure the nonlinear distortion signal-to- noise ratio (DNR) for the 2ChDPs and 2CEOAEs. The DNR is typically 20-30 dB. An intermittent noise rejection technique is implemented in real time that compares a currently acquired ear-canal response with a stored response. Dissimilar responses indicate the presence of intermittent noise, and the noise-contaminated responses are thereby discarded before ensemble averaging.

Original languageEnglish (US)
Pages (from-to)3499-3508
Number of pages10
JournalJournal of the Acoustical Society of America
Volume103
Issue number6
DOIs
StatePublished - Jun 1 1998

Fingerprint

canals
ear
rejection
frequency measurement
chirp
acoustics
Ear
Canals
Rejection
Calibration
probes
products
hearing
subtraction
signal to noise ratios
assembly
low frequencies
cavities

ASJC Scopus subject areas

  • Acoustics and Ultrasonics

Cite this

Double-evoked otoacoustic emissions. II. Intermittent noise rejection, calibration and ear-canal measurements. / Keefe, Douglas H; Ling, Robert.

In: Journal of the Acoustical Society of America, Vol. 103, No. 6, 01.06.1998, p. 3499-3508.

Research output: Contribution to journalArticle

@article{f0dcd89f113749eeb660115b3245739a,
title = "Double-evoked otoacoustic emissions. II. Intermittent noise rejection, calibration and ear-canal measurements",
abstract = "Measurements of double-click-evoked otoacoustics emissions (2CEOAEs) and double-chirp distortion products (2ChDPs) are reported for normal-hearing adults based upon theory presented in an earlier report [Keefe, J. Acoust. Soc. Am. 103, 3489-3498 (1998)]. The nonlinear acoustic response of a probe assembly used in ear-canal measurements is tested in a calibration cavity to compare the double-evoked (2E) technique with existing OAE techniques. The 2E technique reduces the peak distortion by approximately 30 dB relative to existing click-evoked techniques. The 2E subtraction of click responses is partially analogous to current techniques in that the linear response is eliminated, but differs in that high-frequency measurements are improved by eliminating time gating of the cochlear response, and low-frequency measurements are improved by reducing probe distortion, especially when two acoustic sources are used. Because time gating is eliminated, it is straightforward to measure the onset of a click-evoked OAE. The nonlinear coherence function is used to measure the nonlinear distortion signal-to- noise ratio (DNR) for the 2ChDPs and 2CEOAEs. The DNR is typically 20-30 dB. An intermittent noise rejection technique is implemented in real time that compares a currently acquired ear-canal response with a stored response. Dissimilar responses indicate the presence of intermittent noise, and the noise-contaminated responses are thereby discarded before ensemble averaging.",
author = "Keefe, {Douglas H} and Robert Ling",
year = "1998",
month = "6",
day = "1",
doi = "10.1121/1.423058",
language = "English (US)",
volume = "103",
pages = "3499--3508",
journal = "Journal of the Acoustical Society of America",
issn = "0001-4966",
publisher = "Acoustical Society of America",
number = "6",

}

TY - JOUR

T1 - Double-evoked otoacoustic emissions. II. Intermittent noise rejection, calibration and ear-canal measurements

AU - Keefe, Douglas H

AU - Ling, Robert

PY - 1998/6/1

Y1 - 1998/6/1

N2 - Measurements of double-click-evoked otoacoustics emissions (2CEOAEs) and double-chirp distortion products (2ChDPs) are reported for normal-hearing adults based upon theory presented in an earlier report [Keefe, J. Acoust. Soc. Am. 103, 3489-3498 (1998)]. The nonlinear acoustic response of a probe assembly used in ear-canal measurements is tested in a calibration cavity to compare the double-evoked (2E) technique with existing OAE techniques. The 2E technique reduces the peak distortion by approximately 30 dB relative to existing click-evoked techniques. The 2E subtraction of click responses is partially analogous to current techniques in that the linear response is eliminated, but differs in that high-frequency measurements are improved by eliminating time gating of the cochlear response, and low-frequency measurements are improved by reducing probe distortion, especially when two acoustic sources are used. Because time gating is eliminated, it is straightforward to measure the onset of a click-evoked OAE. The nonlinear coherence function is used to measure the nonlinear distortion signal-to- noise ratio (DNR) for the 2ChDPs and 2CEOAEs. The DNR is typically 20-30 dB. An intermittent noise rejection technique is implemented in real time that compares a currently acquired ear-canal response with a stored response. Dissimilar responses indicate the presence of intermittent noise, and the noise-contaminated responses are thereby discarded before ensemble averaging.

AB - Measurements of double-click-evoked otoacoustics emissions (2CEOAEs) and double-chirp distortion products (2ChDPs) are reported for normal-hearing adults based upon theory presented in an earlier report [Keefe, J. Acoust. Soc. Am. 103, 3489-3498 (1998)]. The nonlinear acoustic response of a probe assembly used in ear-canal measurements is tested in a calibration cavity to compare the double-evoked (2E) technique with existing OAE techniques. The 2E technique reduces the peak distortion by approximately 30 dB relative to existing click-evoked techniques. The 2E subtraction of click responses is partially analogous to current techniques in that the linear response is eliminated, but differs in that high-frequency measurements are improved by eliminating time gating of the cochlear response, and low-frequency measurements are improved by reducing probe distortion, especially when two acoustic sources are used. Because time gating is eliminated, it is straightforward to measure the onset of a click-evoked OAE. The nonlinear coherence function is used to measure the nonlinear distortion signal-to- noise ratio (DNR) for the 2ChDPs and 2CEOAEs. The DNR is typically 20-30 dB. An intermittent noise rejection technique is implemented in real time that compares a currently acquired ear-canal response with a stored response. Dissimilar responses indicate the presence of intermittent noise, and the noise-contaminated responses are thereby discarded before ensemble averaging.

UR - http://www.scopus.com/inward/record.url?scp=0031779531&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0031779531&partnerID=8YFLogxK

U2 - 10.1121/1.423058

DO - 10.1121/1.423058

M3 - Article

VL - 103

SP - 3499

EP - 3508

JO - Journal of the Acoustical Society of America

JF - Journal of the Acoustical Society of America

SN - 0001-4966

IS - 6

ER -