Double-evoked otoacoustic emissions. I. Measurement theory and nonlinear coherence

Research output: Contribution to journalArticle

58 Citations (Scopus)

Abstract

An evoked otoacoustic emission (OAE) measurement technique is proposed to better control for probe distortion. Each double-evoking (2E) stimulus sequence includes three, equal-duration subsequences defined as follows: s1(t) is a single chirp or click, s2(t)= εs1(t-τ) is a copy of s1 with relative amplitude ε and delay τ, and s12(t)=s1(t)+s2(t) is the superposition of the first two stimuli. The pressure response to each subsequence is p1, p2, and p12, respectively. The double chirp-evoked distortion product (2ChDP) and double click-evoked otoacoustic emission (2CEOAE) are defined by p(D) =p12-(p1 + p2). The 2ChDP response may be time compressed to analyze as an equivalent 2CEOAE response. The 2E response family provides a complementary representation between DP measurements and double click-evoked OAE measurements. A technique based on nonlinear coherence quantifies random noise in terms of a nonlinear signal-to-noise ratio.

Original languageEnglish (US)
Pages (from-to)3489-3498
Number of pages10
JournalJournal of the Acoustical Society of America
Volume103
Issue number6
DOIs
StatePublished - Jun 1 1998

Fingerprint

chirp
stimuli
random noise
signal to noise ratios
Measurement Theory
probes
products
Stimulus
Signal-to-noise Ratio
Superposition

ASJC Scopus subject areas

  • Arts and Humanities (miscellaneous)
  • Acoustics and Ultrasonics

Cite this

Double-evoked otoacoustic emissions. I. Measurement theory and nonlinear coherence. / Keefe, Douglas H.

In: Journal of the Acoustical Society of America, Vol. 103, No. 6, 01.06.1998, p. 3489-3498.

Research output: Contribution to journalArticle

@article{fad75105d3704495a0c6e41ce6e7249d,
title = "Double-evoked otoacoustic emissions. I. Measurement theory and nonlinear coherence",
abstract = "An evoked otoacoustic emission (OAE) measurement technique is proposed to better control for probe distortion. Each double-evoking (2E) stimulus sequence includes three, equal-duration subsequences defined as follows: s1(t) is a single chirp or click, s2(t)= εs1(t-τ) is a copy of s1 with relative amplitude ε and delay τ, and s12(t)=s1(t)+s2(t) is the superposition of the first two stimuli. The pressure response to each subsequence is p1, p2, and p12, respectively. The double chirp-evoked distortion product (2ChDP) and double click-evoked otoacoustic emission (2CEOAE) are defined by p(D) =p12-(p1 + p2). The 2ChDP response may be time compressed to analyze as an equivalent 2CEOAE response. The 2E response family provides a complementary representation between DP measurements and double click-evoked OAE measurements. A technique based on nonlinear coherence quantifies random noise in terms of a nonlinear signal-to-noise ratio.",
author = "Keefe, {Douglas H}",
year = "1998",
month = "6",
day = "1",
doi = "10.1121/1.423057",
language = "English (US)",
volume = "103",
pages = "3489--3498",
journal = "Journal of the Acoustical Society of America",
issn = "0001-4966",
publisher = "Acoustical Society of America",
number = "6",

}

TY - JOUR

T1 - Double-evoked otoacoustic emissions. I. Measurement theory and nonlinear coherence

AU - Keefe, Douglas H

PY - 1998/6/1

Y1 - 1998/6/1

N2 - An evoked otoacoustic emission (OAE) measurement technique is proposed to better control for probe distortion. Each double-evoking (2E) stimulus sequence includes three, equal-duration subsequences defined as follows: s1(t) is a single chirp or click, s2(t)= εs1(t-τ) is a copy of s1 with relative amplitude ε and delay τ, and s12(t)=s1(t)+s2(t) is the superposition of the first two stimuli. The pressure response to each subsequence is p1, p2, and p12, respectively. The double chirp-evoked distortion product (2ChDP) and double click-evoked otoacoustic emission (2CEOAE) are defined by p(D) =p12-(p1 + p2). The 2ChDP response may be time compressed to analyze as an equivalent 2CEOAE response. The 2E response family provides a complementary representation between DP measurements and double click-evoked OAE measurements. A technique based on nonlinear coherence quantifies random noise in terms of a nonlinear signal-to-noise ratio.

AB - An evoked otoacoustic emission (OAE) measurement technique is proposed to better control for probe distortion. Each double-evoking (2E) stimulus sequence includes three, equal-duration subsequences defined as follows: s1(t) is a single chirp or click, s2(t)= εs1(t-τ) is a copy of s1 with relative amplitude ε and delay τ, and s12(t)=s1(t)+s2(t) is the superposition of the first two stimuli. The pressure response to each subsequence is p1, p2, and p12, respectively. The double chirp-evoked distortion product (2ChDP) and double click-evoked otoacoustic emission (2CEOAE) are defined by p(D) =p12-(p1 + p2). The 2ChDP response may be time compressed to analyze as an equivalent 2CEOAE response. The 2E response family provides a complementary representation between DP measurements and double click-evoked OAE measurements. A technique based on nonlinear coherence quantifies random noise in terms of a nonlinear signal-to-noise ratio.

UR - http://www.scopus.com/inward/record.url?scp=0031779378&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0031779378&partnerID=8YFLogxK

U2 - 10.1121/1.423057

DO - 10.1121/1.423057

M3 - Article

AN - SCOPUS:0031779378

VL - 103

SP - 3489

EP - 3498

JO - Journal of the Acoustical Society of America

JF - Journal of the Acoustical Society of America

SN - 0001-4966

IS - 6

ER -