Do all DOAS configurations provide the same benefits?

Shihan Deng, Josephine Lau, Jae Weon Jeong

Research output: Contribution to journalArticle

7 Citations (Scopus)

Abstract

There are many potential benefits in applying dedicated outdoor air systems (DOAS) such as it is easier to ensure proper ventilation; decoupling latent and sensible loads control; providing energy use and demand reduction and better indoor environmental quality (IEQ). To realize the ventilation benefit of DOAS the OA must be supplied to each occupied space, or either directly, or in conjunction with, local units. There is more than one way to condition the air from a DOAS unit. While the dehumidified OA should be delivered cold whenever possible, as the space sensible cooling load decreases, this cold air may provide more sensible cooling than the space requires, resulting in overcooling. When the potential for overcooling exists, design engineers typically may consider implementing CA temperature reset to reduce the cooling capacity. When the conditioned OA is delivered at a cold temperature, rather than reheated to neutral, this configuration offers the opportunity to reduce the local equipment size and hence also its capital and possibly operational energy costs. When the OA is delivered at a cold temperature, rather than reheated to neutral, this configuration may also permit the downsizing of the local units.

Original languageEnglish (US)
Pages (from-to)52-57
Number of pages6
JournalASHRAE Journal
Volume56
Issue number7
StatePublished - Jul 1 2014

Fingerprint

Air
Cooling
Ventilation
Temperature
Engineers
Costs

ASJC Scopus subject areas

  • Building and Construction
  • Mechanical Engineering

Cite this

Do all DOAS configurations provide the same benefits? / Deng, Shihan; Lau, Josephine; Jeong, Jae Weon.

In: ASHRAE Journal, Vol. 56, No. 7, 01.07.2014, p. 52-57.

Research output: Contribution to journalArticle

Deng, S, Lau, J & Jeong, JW 2014, 'Do all DOAS configurations provide the same benefits?', ASHRAE Journal, vol. 56, no. 7, pp. 52-57.
Deng, Shihan ; Lau, Josephine ; Jeong, Jae Weon. / Do all DOAS configurations provide the same benefits?. In: ASHRAE Journal. 2014 ; Vol. 56, No. 7. pp. 52-57.
@article{b6521941cce145c08b3cd73becf1cdbd,
title = "Do all DOAS configurations provide the same benefits?",
abstract = "There are many potential benefits in applying dedicated outdoor air systems (DOAS) such as it is easier to ensure proper ventilation; decoupling latent and sensible loads control; providing energy use and demand reduction and better indoor environmental quality (IEQ). To realize the ventilation benefit of DOAS the OA must be supplied to each occupied space, or either directly, or in conjunction with, local units. There is more than one way to condition the air from a DOAS unit. While the dehumidified OA should be delivered cold whenever possible, as the space sensible cooling load decreases, this cold air may provide more sensible cooling than the space requires, resulting in overcooling. When the potential for overcooling exists, design engineers typically may consider implementing CA temperature reset to reduce the cooling capacity. When the conditioned OA is delivered at a cold temperature, rather than reheated to neutral, this configuration offers the opportunity to reduce the local equipment size and hence also its capital and possibly operational energy costs. When the OA is delivered at a cold temperature, rather than reheated to neutral, this configuration may also permit the downsizing of the local units.",
author = "Shihan Deng and Josephine Lau and Jeong, {Jae Weon}",
year = "2014",
month = "7",
day = "1",
language = "English (US)",
volume = "56",
pages = "52--57",
journal = "ASHRAE Journal",
issn = "0001-2491",
publisher = "Amer. Soc. Heating, Ref. Air-Conditoning Eng. Inc.",
number = "7",

}

TY - JOUR

T1 - Do all DOAS configurations provide the same benefits?

AU - Deng, Shihan

AU - Lau, Josephine

AU - Jeong, Jae Weon

PY - 2014/7/1

Y1 - 2014/7/1

N2 - There are many potential benefits in applying dedicated outdoor air systems (DOAS) such as it is easier to ensure proper ventilation; decoupling latent and sensible loads control; providing energy use and demand reduction and better indoor environmental quality (IEQ). To realize the ventilation benefit of DOAS the OA must be supplied to each occupied space, or either directly, or in conjunction with, local units. There is more than one way to condition the air from a DOAS unit. While the dehumidified OA should be delivered cold whenever possible, as the space sensible cooling load decreases, this cold air may provide more sensible cooling than the space requires, resulting in overcooling. When the potential for overcooling exists, design engineers typically may consider implementing CA temperature reset to reduce the cooling capacity. When the conditioned OA is delivered at a cold temperature, rather than reheated to neutral, this configuration offers the opportunity to reduce the local equipment size and hence also its capital and possibly operational energy costs. When the OA is delivered at a cold temperature, rather than reheated to neutral, this configuration may also permit the downsizing of the local units.

AB - There are many potential benefits in applying dedicated outdoor air systems (DOAS) such as it is easier to ensure proper ventilation; decoupling latent and sensible loads control; providing energy use and demand reduction and better indoor environmental quality (IEQ). To realize the ventilation benefit of DOAS the OA must be supplied to each occupied space, or either directly, or in conjunction with, local units. There is more than one way to condition the air from a DOAS unit. While the dehumidified OA should be delivered cold whenever possible, as the space sensible cooling load decreases, this cold air may provide more sensible cooling than the space requires, resulting in overcooling. When the potential for overcooling exists, design engineers typically may consider implementing CA temperature reset to reduce the cooling capacity. When the conditioned OA is delivered at a cold temperature, rather than reheated to neutral, this configuration offers the opportunity to reduce the local equipment size and hence also its capital and possibly operational energy costs. When the OA is delivered at a cold temperature, rather than reheated to neutral, this configuration may also permit the downsizing of the local units.

UR - http://www.scopus.com/inward/record.url?scp=84942878701&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84942878701&partnerID=8YFLogxK

M3 - Article

AN - SCOPUS:84942878701

VL - 56

SP - 52

EP - 57

JO - ASHRAE Journal

JF - ASHRAE Journal

SN - 0001-2491

IS - 7

ER -