Development of a mobile motion capture (MO 2 CA) system for future military application

Research output: Contribution to journalArticle

Abstract

State-of-the-art three-dimensional motion analysis systems, which are utilized to predict, diagnose, and treat many musculoskeletal and neurological disorders, are expensive and space consuming. These systems have only been widely used in large research facilities because of their lack of this transportability. Since device portability is a critically important in the military, most small military hospitals are therefore deprived of these systems. The purpose of this study was to develop a mobile motion capture system, MO 2 CA, to automatically detect the movement of the human body. Twenty healthy young adults participated in this study. Colored tape was attached on the heel, and subjects walked on the treadmill at three different speeds: Preferred, fast, and slow. Two motion capture systems were used concurrently: Qualisys (100 Hz) and MO 2 CA (60 Hz). Four dependent variables were: Stride length, stride time, stride length variability, and stride time variability. Paired t-tests, Pearson correlation, and Bland-Altman plots were used to investigate the statistical differences between two systems. No significant differences were found for all dependent variables. Regression and Bland-Altman plots showed strong agreements between the two systems. Our MO 2 CA shows a potential for real-time tracking of biomechanical changes in gait, which is extremely important for military use.

Original languageEnglish (US)
Pages (from-to)65-71
Number of pages7
JournalMilitary medicine
Volume184
DOIs
StatePublished - Mar 1 2019

Fingerprint

Military Hospitals
Heel
Nervous System Diseases
Gait
Human Body
Young Adult
Equipment and Supplies
Research

Keywords

  • gait performance evaluation
  • portable motion capture system

ASJC Scopus subject areas

  • Public Health, Environmental and Occupational Health

Cite this

Development of a mobile motion capture (MO 2 CA) system for future military application . / Parks, Melissa; Chien, Jung Hung; Siu, Ka Chun.

In: Military medicine, Vol. 184, 01.03.2019, p. 65-71.

Research output: Contribution to journalArticle

@article{e3366e9374ad4e038b894bdcb0ecb8e8,
title = "Development of a mobile motion capture (MO 2 CA) system for future military application",
abstract = "State-of-the-art three-dimensional motion analysis systems, which are utilized to predict, diagnose, and treat many musculoskeletal and neurological disorders, are expensive and space consuming. These systems have only been widely used in large research facilities because of their lack of this transportability. Since device portability is a critically important in the military, most small military hospitals are therefore deprived of these systems. The purpose of this study was to develop a mobile motion capture system, MO 2 CA, to automatically detect the movement of the human body. Twenty healthy young adults participated in this study. Colored tape was attached on the heel, and subjects walked on the treadmill at three different speeds: Preferred, fast, and slow. Two motion capture systems were used concurrently: Qualisys (100 Hz) and MO 2 CA (60 Hz). Four dependent variables were: Stride length, stride time, stride length variability, and stride time variability. Paired t-tests, Pearson correlation, and Bland-Altman plots were used to investigate the statistical differences between two systems. No significant differences were found for all dependent variables. Regression and Bland-Altman plots showed strong agreements between the two systems. Our MO 2 CA shows a potential for real-time tracking of biomechanical changes in gait, which is extremely important for military use.",
keywords = "gait performance evaluation, portable motion capture system",
author = "Melissa Parks and Chien, {Jung Hung} and Siu, {Ka Chun}",
year = "2019",
month = "3",
day = "1",
doi = "10.1093/milmed/usy312",
language = "English (US)",
volume = "184",
pages = "65--71",
journal = "Military Medicine",
issn = "0026-4075",
publisher = "Association of Military Surgeons of the US",

}

TY - JOUR

T1 - Development of a mobile motion capture (MO 2 CA) system for future military application

AU - Parks, Melissa

AU - Chien, Jung Hung

AU - Siu, Ka Chun

PY - 2019/3/1

Y1 - 2019/3/1

N2 - State-of-the-art three-dimensional motion analysis systems, which are utilized to predict, diagnose, and treat many musculoskeletal and neurological disorders, are expensive and space consuming. These systems have only been widely used in large research facilities because of their lack of this transportability. Since device portability is a critically important in the military, most small military hospitals are therefore deprived of these systems. The purpose of this study was to develop a mobile motion capture system, MO 2 CA, to automatically detect the movement of the human body. Twenty healthy young adults participated in this study. Colored tape was attached on the heel, and subjects walked on the treadmill at three different speeds: Preferred, fast, and slow. Two motion capture systems were used concurrently: Qualisys (100 Hz) and MO 2 CA (60 Hz). Four dependent variables were: Stride length, stride time, stride length variability, and stride time variability. Paired t-tests, Pearson correlation, and Bland-Altman plots were used to investigate the statistical differences between two systems. No significant differences were found for all dependent variables. Regression and Bland-Altman plots showed strong agreements between the two systems. Our MO 2 CA shows a potential for real-time tracking of biomechanical changes in gait, which is extremely important for military use.

AB - State-of-the-art three-dimensional motion analysis systems, which are utilized to predict, diagnose, and treat many musculoskeletal and neurological disorders, are expensive and space consuming. These systems have only been widely used in large research facilities because of their lack of this transportability. Since device portability is a critically important in the military, most small military hospitals are therefore deprived of these systems. The purpose of this study was to develop a mobile motion capture system, MO 2 CA, to automatically detect the movement of the human body. Twenty healthy young adults participated in this study. Colored tape was attached on the heel, and subjects walked on the treadmill at three different speeds: Preferred, fast, and slow. Two motion capture systems were used concurrently: Qualisys (100 Hz) and MO 2 CA (60 Hz). Four dependent variables were: Stride length, stride time, stride length variability, and stride time variability. Paired t-tests, Pearson correlation, and Bland-Altman plots were used to investigate the statistical differences between two systems. No significant differences were found for all dependent variables. Regression and Bland-Altman plots showed strong agreements between the two systems. Our MO 2 CA shows a potential for real-time tracking of biomechanical changes in gait, which is extremely important for military use.

KW - gait performance evaluation

KW - portable motion capture system

UR - http://www.scopus.com/inward/record.url?scp=85063669418&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85063669418&partnerID=8YFLogxK

U2 - 10.1093/milmed/usy312

DO - 10.1093/milmed/usy312

M3 - Article

C2 - 30901400

AN - SCOPUS:85063669418

VL - 184

SP - 65

EP - 71

JO - Military Medicine

JF - Military Medicine

SN - 0026-4075

ER -