Determination of chlorine with radical emission using laser-induced breakdown spectroscopy coupled with partial least square regression

Wen Zhang, Ran Zhou, Ping Yang, Kun Liu, Jiujiang Yan, Peiyuan Gao, Zhiyang Tang, Xiangyou Li, Yongfeng Lu, Xiaoyan Zeng

Research output: Contribution to journalArticle

2 Citations (Scopus)

Abstract

Chlorine is a crucial element which may cause the corrosion of reinforced concrete. However, the strongest chlorine atom/ion emission lines are in the UV region and the ground state atom is hard to excite by conventional single-pulsed laser-induced breakdown spectroscopy (SP-LIBS). Radical emission is a feasible alternative to atom/ion emission when detecting chlorine concentration. Here, Cl atomic emission and calcium chloride (CaCl) radicals were detected in SP-LIBS, the calibrations of both emissions were compared. To further improve the accuracy, partial least square regression (PLSR) was adopted to establish the calibrations. The results showed that CaCl radical signal is stronger than Cl atomic signal with low energy SP-LIBS in open air, achieving a LoD (limit of detection) of 0.0404 wt%. Meanwhile, CaCl calibration had a better accuracy with coefficient of determination (R2) and root mean square error of cross validation (RMSECV) of 0.9930 and 0.2016 wt% with the help of PLSR. In conclusion, this work provided a potential approach for Chlorine determination in industry.

Original languageEnglish (US)
Pages (from-to)93-96
Number of pages4
JournalTalanta
Volume198
DOIs
StatePublished - Jun 1 2019

Fingerprint

Laser induced breakdown spectroscopy
Chlorine
Calcium Chloride
Pulsed lasers
Calibration
Atoms
Ions
Mean square error
Ground state
Reinforced concrete
Corrosion
Air
Industry

Keywords

  • CaCl radical
  • Chloride
  • Laser-induced breakdown spectroscopy
  • PLSR

ASJC Scopus subject areas

  • Analytical Chemistry

Cite this

Determination of chlorine with radical emission using laser-induced breakdown spectroscopy coupled with partial least square regression. / Zhang, Wen; Zhou, Ran; Yang, Ping; Liu, Kun; Yan, Jiujiang; Gao, Peiyuan; Tang, Zhiyang; Li, Xiangyou; Lu, Yongfeng; Zeng, Xiaoyan.

In: Talanta, Vol. 198, 01.06.2019, p. 93-96.

Research output: Contribution to journalArticle

Zhang, Wen ; Zhou, Ran ; Yang, Ping ; Liu, Kun ; Yan, Jiujiang ; Gao, Peiyuan ; Tang, Zhiyang ; Li, Xiangyou ; Lu, Yongfeng ; Zeng, Xiaoyan. / Determination of chlorine with radical emission using laser-induced breakdown spectroscopy coupled with partial least square regression. In: Talanta. 2019 ; Vol. 198. pp. 93-96.
@article{bc2a26c13eda410f99acce35fe07c075,
title = "Determination of chlorine with radical emission using laser-induced breakdown spectroscopy coupled with partial least square regression",
abstract = "Chlorine is a crucial element which may cause the corrosion of reinforced concrete. However, the strongest chlorine atom/ion emission lines are in the UV region and the ground state atom is hard to excite by conventional single-pulsed laser-induced breakdown spectroscopy (SP-LIBS). Radical emission is a feasible alternative to atom/ion emission when detecting chlorine concentration. Here, Cl atomic emission and calcium chloride (CaCl) radicals were detected in SP-LIBS, the calibrations of both emissions were compared. To further improve the accuracy, partial least square regression (PLSR) was adopted to establish the calibrations. The results showed that CaCl radical signal is stronger than Cl atomic signal with low energy SP-LIBS in open air, achieving a LoD (limit of detection) of 0.0404 wt{\%}. Meanwhile, CaCl calibration had a better accuracy with coefficient of determination (R2) and root mean square error of cross validation (RMSECV) of 0.9930 and 0.2016 wt{\%} with the help of PLSR. In conclusion, this work provided a potential approach for Chlorine determination in industry.",
keywords = "CaCl radical, Chloride, Laser-induced breakdown spectroscopy, PLSR",
author = "Wen Zhang and Ran Zhou and Ping Yang and Kun Liu and Jiujiang Yan and Peiyuan Gao and Zhiyang Tang and Xiangyou Li and Yongfeng Lu and Xiaoyan Zeng",
year = "2019",
month = "6",
day = "1",
doi = "10.1016/j.talanta.2019.01.102",
language = "English (US)",
volume = "198",
pages = "93--96",
journal = "Talanta",
issn = "0039-9140",
publisher = "Elsevier",

}

TY - JOUR

T1 - Determination of chlorine with radical emission using laser-induced breakdown spectroscopy coupled with partial least square regression

AU - Zhang, Wen

AU - Zhou, Ran

AU - Yang, Ping

AU - Liu, Kun

AU - Yan, Jiujiang

AU - Gao, Peiyuan

AU - Tang, Zhiyang

AU - Li, Xiangyou

AU - Lu, Yongfeng

AU - Zeng, Xiaoyan

PY - 2019/6/1

Y1 - 2019/6/1

N2 - Chlorine is a crucial element which may cause the corrosion of reinforced concrete. However, the strongest chlorine atom/ion emission lines are in the UV region and the ground state atom is hard to excite by conventional single-pulsed laser-induced breakdown spectroscopy (SP-LIBS). Radical emission is a feasible alternative to atom/ion emission when detecting chlorine concentration. Here, Cl atomic emission and calcium chloride (CaCl) radicals were detected in SP-LIBS, the calibrations of both emissions were compared. To further improve the accuracy, partial least square regression (PLSR) was adopted to establish the calibrations. The results showed that CaCl radical signal is stronger than Cl atomic signal with low energy SP-LIBS in open air, achieving a LoD (limit of detection) of 0.0404 wt%. Meanwhile, CaCl calibration had a better accuracy with coefficient of determination (R2) and root mean square error of cross validation (RMSECV) of 0.9930 and 0.2016 wt% with the help of PLSR. In conclusion, this work provided a potential approach for Chlorine determination in industry.

AB - Chlorine is a crucial element which may cause the corrosion of reinforced concrete. However, the strongest chlorine atom/ion emission lines are in the UV region and the ground state atom is hard to excite by conventional single-pulsed laser-induced breakdown spectroscopy (SP-LIBS). Radical emission is a feasible alternative to atom/ion emission when detecting chlorine concentration. Here, Cl atomic emission and calcium chloride (CaCl) radicals were detected in SP-LIBS, the calibrations of both emissions were compared. To further improve the accuracy, partial least square regression (PLSR) was adopted to establish the calibrations. The results showed that CaCl radical signal is stronger than Cl atomic signal with low energy SP-LIBS in open air, achieving a LoD (limit of detection) of 0.0404 wt%. Meanwhile, CaCl calibration had a better accuracy with coefficient of determination (R2) and root mean square error of cross validation (RMSECV) of 0.9930 and 0.2016 wt% with the help of PLSR. In conclusion, this work provided a potential approach for Chlorine determination in industry.

KW - CaCl radical

KW - Chloride

KW - Laser-induced breakdown spectroscopy

KW - PLSR

UR - http://www.scopus.com/inward/record.url?scp=85060864221&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85060864221&partnerID=8YFLogxK

U2 - 10.1016/j.talanta.2019.01.102

DO - 10.1016/j.talanta.2019.01.102

M3 - Article

C2 - 30876608

AN - SCOPUS:85060864221

VL - 198

SP - 93

EP - 96

JO - Talanta

JF - Talanta

SN - 0039-9140