Design and development of a free-standing 4-DOF infant surgical table

Scott R. Siebler, Carl A. Nelson, Thomas Hejkal

Research output: Chapter in Book/Report/Conference proceedingConference contribution

1 Citation (Scopus)

Abstract

Retinopathy of prematurity is caused by abnormal blood vessel development in the retina of a premature infant. Current options for surgery tables used in laser treatment of this condition are limited. Full-size operating tables or table attachments are used but provide restricted patient manipulation and cause the surgeon to assume ergonomically undesirable positions. A stand-alone four-degree-of-freedom (4-DOF) infant surgical table was designed and is presented in this paper. The new table enables the surgeon to manipulate the patient while sitting in a comfortable position. The table platform can pitch left/right and fore/aft. The table platform can rotate 360° and translate vertically. Two linear actuators and a motor with ball screw provide the three degrees of freedom for table pitch and rotation through a spherical wrist mechanism. A ball screw and motor achieve vertical movement of the table platform. The rigors of surgery and associated space constraints were accounted for in this design. The design consists of three subassemblies which can be disassembled for transport between operating theaters. A wide base is used to prevent the table from tipping. Biocompatible materials have been selected for all parts. Lastly, foot controls are used to keep the surgeon's hands free. BACKGROUND: Retinopathy of prematurity (ROP) can be successfully treated using laser photocoagulation of the peripheral avascular retina. A laser is directed through the pupil of the patient's eye, causing burns in the retina peripheral to the abnormal vessels.

Original languageEnglish (US)
Title of host publicationProceedings of the ASME International Design Engineering Technical Conferences and Computers and Information in Engineering Conference 2009, DETC2009
Pages711-720
Number of pages10
EditionPART B
DOIs
StatePublished - Jun 25 2010
Event2009 ASME International Design Engineering Technical Conferences and Computers and Information in Engineering Conference, DETC2009 - San Diego, CA, United States
Duration: Aug 30 2009Sep 2 2009

Publication series

NameProceedings of the ASME International Design Engineering Technical Conferences and Computers and Information in Engineering Conference 2009, DETC2009
NumberPART B
Volume7

Conference

Conference2009 ASME International Design Engineering Technical Conferences and Computers and Information in Engineering Conference, DETC2009
CountryUnited States
CitySan Diego, CA
Period8/30/099/2/09

Fingerprint

Ball screws
Surgery
Lasers
Linear actuators
Theaters
Blood vessels
Degrees of freedom (mechanics)
Biomaterials

Keywords

  • Infant surgical table
  • Linear actuation
  • Retinopathy of prematurity
  • Spherical wrist mechanism

ASJC Scopus subject areas

  • Computer Networks and Communications
  • Hardware and Architecture
  • Electrical and Electronic Engineering

Cite this

Siebler, S. R., Nelson, C. A., & Hejkal, T. (2010). Design and development of a free-standing 4-DOF infant surgical table. In Proceedings of the ASME International Design Engineering Technical Conferences and Computers and Information in Engineering Conference 2009, DETC2009 (PART B ed., pp. 711-720). (Proceedings of the ASME International Design Engineering Technical Conferences and Computers and Information in Engineering Conference 2009, DETC2009; Vol. 7, No. PART B). https://doi.org/10.1115/DETC2009-86790

Design and development of a free-standing 4-DOF infant surgical table. / Siebler, Scott R.; Nelson, Carl A.; Hejkal, Thomas.

Proceedings of the ASME International Design Engineering Technical Conferences and Computers and Information in Engineering Conference 2009, DETC2009. PART B. ed. 2010. p. 711-720 (Proceedings of the ASME International Design Engineering Technical Conferences and Computers and Information in Engineering Conference 2009, DETC2009; Vol. 7, No. PART B).

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Siebler, SR, Nelson, CA & Hejkal, T 2010, Design and development of a free-standing 4-DOF infant surgical table. in Proceedings of the ASME International Design Engineering Technical Conferences and Computers and Information in Engineering Conference 2009, DETC2009. PART B edn, Proceedings of the ASME International Design Engineering Technical Conferences and Computers and Information in Engineering Conference 2009, DETC2009, no. PART B, vol. 7, pp. 711-720, 2009 ASME International Design Engineering Technical Conferences and Computers and Information in Engineering Conference, DETC2009, San Diego, CA, United States, 8/30/09. https://doi.org/10.1115/DETC2009-86790
Siebler SR, Nelson CA, Hejkal T. Design and development of a free-standing 4-DOF infant surgical table. In Proceedings of the ASME International Design Engineering Technical Conferences and Computers and Information in Engineering Conference 2009, DETC2009. PART B ed. 2010. p. 711-720. (Proceedings of the ASME International Design Engineering Technical Conferences and Computers and Information in Engineering Conference 2009, DETC2009; PART B). https://doi.org/10.1115/DETC2009-86790
Siebler, Scott R. ; Nelson, Carl A. ; Hejkal, Thomas. / Design and development of a free-standing 4-DOF infant surgical table. Proceedings of the ASME International Design Engineering Technical Conferences and Computers and Information in Engineering Conference 2009, DETC2009. PART B. ed. 2010. pp. 711-720 (Proceedings of the ASME International Design Engineering Technical Conferences and Computers and Information in Engineering Conference 2009, DETC2009; PART B).
@inproceedings{5950afb1b82746b08706ce243e199a45,
title = "Design and development of a free-standing 4-DOF infant surgical table",
abstract = "Retinopathy of prematurity is caused by abnormal blood vessel development in the retina of a premature infant. Current options for surgery tables used in laser treatment of this condition are limited. Full-size operating tables or table attachments are used but provide restricted patient manipulation and cause the surgeon to assume ergonomically undesirable positions. A stand-alone four-degree-of-freedom (4-DOF) infant surgical table was designed and is presented in this paper. The new table enables the surgeon to manipulate the patient while sitting in a comfortable position. The table platform can pitch left/right and fore/aft. The table platform can rotate 360° and translate vertically. Two linear actuators and a motor with ball screw provide the three degrees of freedom for table pitch and rotation through a spherical wrist mechanism. A ball screw and motor achieve vertical movement of the table platform. The rigors of surgery and associated space constraints were accounted for in this design. The design consists of three subassemblies which can be disassembled for transport between operating theaters. A wide base is used to prevent the table from tipping. Biocompatible materials have been selected for all parts. Lastly, foot controls are used to keep the surgeon's hands free. BACKGROUND: Retinopathy of prematurity (ROP) can be successfully treated using laser photocoagulation of the peripheral avascular retina. A laser is directed through the pupil of the patient's eye, causing burns in the retina peripheral to the abnormal vessels.",
keywords = "Infant surgical table, Linear actuation, Retinopathy of prematurity, Spherical wrist mechanism",
author = "Siebler, {Scott R.} and Nelson, {Carl A.} and Thomas Hejkal",
year = "2010",
month = "6",
day = "25",
doi = "10.1115/DETC2009-86790",
language = "English (US)",
isbn = "9780791849040",
series = "Proceedings of the ASME International Design Engineering Technical Conferences and Computers and Information in Engineering Conference 2009, DETC2009",
number = "PART B",
pages = "711--720",
booktitle = "Proceedings of the ASME International Design Engineering Technical Conferences and Computers and Information in Engineering Conference 2009, DETC2009",
edition = "PART B",

}

TY - GEN

T1 - Design and development of a free-standing 4-DOF infant surgical table

AU - Siebler, Scott R.

AU - Nelson, Carl A.

AU - Hejkal, Thomas

PY - 2010/6/25

Y1 - 2010/6/25

N2 - Retinopathy of prematurity is caused by abnormal blood vessel development in the retina of a premature infant. Current options for surgery tables used in laser treatment of this condition are limited. Full-size operating tables or table attachments are used but provide restricted patient manipulation and cause the surgeon to assume ergonomically undesirable positions. A stand-alone four-degree-of-freedom (4-DOF) infant surgical table was designed and is presented in this paper. The new table enables the surgeon to manipulate the patient while sitting in a comfortable position. The table platform can pitch left/right and fore/aft. The table platform can rotate 360° and translate vertically. Two linear actuators and a motor with ball screw provide the three degrees of freedom for table pitch and rotation through a spherical wrist mechanism. A ball screw and motor achieve vertical movement of the table platform. The rigors of surgery and associated space constraints were accounted for in this design. The design consists of three subassemblies which can be disassembled for transport between operating theaters. A wide base is used to prevent the table from tipping. Biocompatible materials have been selected for all parts. Lastly, foot controls are used to keep the surgeon's hands free. BACKGROUND: Retinopathy of prematurity (ROP) can be successfully treated using laser photocoagulation of the peripheral avascular retina. A laser is directed through the pupil of the patient's eye, causing burns in the retina peripheral to the abnormal vessels.

AB - Retinopathy of prematurity is caused by abnormal blood vessel development in the retina of a premature infant. Current options for surgery tables used in laser treatment of this condition are limited. Full-size operating tables or table attachments are used but provide restricted patient manipulation and cause the surgeon to assume ergonomically undesirable positions. A stand-alone four-degree-of-freedom (4-DOF) infant surgical table was designed and is presented in this paper. The new table enables the surgeon to manipulate the patient while sitting in a comfortable position. The table platform can pitch left/right and fore/aft. The table platform can rotate 360° and translate vertically. Two linear actuators and a motor with ball screw provide the three degrees of freedom for table pitch and rotation through a spherical wrist mechanism. A ball screw and motor achieve vertical movement of the table platform. The rigors of surgery and associated space constraints were accounted for in this design. The design consists of three subassemblies which can be disassembled for transport between operating theaters. A wide base is used to prevent the table from tipping. Biocompatible materials have been selected for all parts. Lastly, foot controls are used to keep the surgeon's hands free. BACKGROUND: Retinopathy of prematurity (ROP) can be successfully treated using laser photocoagulation of the peripheral avascular retina. A laser is directed through the pupil of the patient's eye, causing burns in the retina peripheral to the abnormal vessels.

KW - Infant surgical table

KW - Linear actuation

KW - Retinopathy of prematurity

KW - Spherical wrist mechanism

UR - http://www.scopus.com/inward/record.url?scp=77953737448&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=77953737448&partnerID=8YFLogxK

U2 - 10.1115/DETC2009-86790

DO - 10.1115/DETC2009-86790

M3 - Conference contribution

AN - SCOPUS:77953737448

SN - 9780791849040

T3 - Proceedings of the ASME International Design Engineering Technical Conferences and Computers and Information in Engineering Conference 2009, DETC2009

SP - 711

EP - 720

BT - Proceedings of the ASME International Design Engineering Technical Conferences and Computers and Information in Engineering Conference 2009, DETC2009

ER -