The use of short-term mechanical circulatory support during postcardiotomy acute heart failure provides an opportunity to stabilize the patient's hemodynamic state while determining the best long-term strategy. Because all of these devices require anticoagulation treatment of various intensities, management of major bleeding can be critical for the overall outcome of the therapy. In this regard, the newest generation of magnetically levitated centrifugal-fl ow pumps affords several potential advantages in terms of thrombogenicity and eventual discontinuation of anticoagulation treatment. We report the use of a short-term biventricular assist device (Levitronix CentriMag) for 94 days in a 55-year-old man with refractory ventricular arrhythmias after combined heart surgery. Despite serious complications while the patient was on the assist device, including severe intestinal bleeding with the necessity of discontinuing anticoagulation for 10 days and, ultimately, hemicolectomy, the circulatory support was completed with successful heart transplantation.

Original languageEnglish (US)
Pages (from-to)E409-E410
JournalHeart Surgery Forum
Volume13
Issue number6
DOIs
StatePublished - Dec 1 2010

Fingerprint

Hemorrhage
Equipment and Supplies
Heart Transplantation
Thoracic Surgery
Cardiac Arrhythmias
Therapeutics
Heart Failure
Hemodynamics

ASJC Scopus subject areas

  • Surgery
  • Cardiology and Cardiovascular Medicine

Cite this

Comprehensive management of severe intestinal bleeding in a patient supported for 94 days by the biventricular levitronix centrimag system. / Netuka, Ivan; Szarszoi, Ondrej; Maly, Jiri; Adamira, Marek; Turek, Daniel; Besik, Josef; Urban, Marian; Riha, Hynek; Kotulak, Tomas; Pirk, Jan.

In: Heart Surgery Forum, Vol. 13, No. 6, 01.12.2010, p. E409-E410.

Research output: Contribution to journalArticle

Netuka, I, Szarszoi, O, Maly, J, Adamira, M, Turek, D, Besik, J, Urban, M, Riha, H, Kotulak, T & Pirk, J 2010, 'Comprehensive management of severe intestinal bleeding in a patient supported for 94 days by the biventricular levitronix centrimag system', Heart Surgery Forum, vol. 13, no. 6, pp. E409-E410. https://doi.org/10.1532/HSF98.20101068
Netuka, Ivan ; Szarszoi, Ondrej ; Maly, Jiri ; Adamira, Marek ; Turek, Daniel ; Besik, Josef ; Urban, Marian ; Riha, Hynek ; Kotulak, Tomas ; Pirk, Jan. / Comprehensive management of severe intestinal bleeding in a patient supported for 94 days by the biventricular levitronix centrimag system. In: Heart Surgery Forum. 2010 ; Vol. 13, No. 6. pp. E409-E410.
@article{0112d72f8fa84948a58b3f150758dc64,
title = "Comprehensive management of severe intestinal bleeding in a patient supported for 94 days by the biventricular levitronix centrimag system",
abstract = "The use of short-term mechanical circulatory support during postcardiotomy acute heart failure provides an opportunity to stabilize the patient's hemodynamic state while determining the best long-term strategy. Because all of these devices require anticoagulation treatment of various intensities, management of major bleeding can be critical for the overall outcome of the therapy. In this regard, the newest generation of magnetically levitated centrifugal-fl ow pumps affords several potential advantages in terms of thrombogenicity and eventual discontinuation of anticoagulation treatment. We report the use of a short-term biventricular assist device (Levitronix CentriMag) for 94 days in a 55-year-old man with refractory ventricular arrhythmias after combined heart surgery. Despite serious complications while the patient was on the assist device, including severe intestinal bleeding with the necessity of discontinuing anticoagulation for 10 days and, ultimately, hemicolectomy, the circulatory support was completed with successful heart transplantation.",
author = "Ivan Netuka and Ondrej Szarszoi and Jiri Maly and Marek Adamira and Daniel Turek and Josef Besik and Marian Urban and Hynek Riha and Tomas Kotulak and Jan Pirk",
year = "2010",
month = "12",
day = "1",
doi = "10.1532/HSF98.20101068",
language = "English (US)",
volume = "13",
pages = "E409--E410",
journal = "The heart surgery forum",
issn = "1098-3511",
publisher = "Carden Jennings Publishing Co. Ltd",
number = "6",

}

TY - JOUR

T1 - Comprehensive management of severe intestinal bleeding in a patient supported for 94 days by the biventricular levitronix centrimag system

AU - Netuka, Ivan

AU - Szarszoi, Ondrej

AU - Maly, Jiri

AU - Adamira, Marek

AU - Turek, Daniel

AU - Besik, Josef

AU - Urban, Marian

AU - Riha, Hynek

AU - Kotulak, Tomas

AU - Pirk, Jan

PY - 2010/12/1

Y1 - 2010/12/1

N2 - The use of short-term mechanical circulatory support during postcardiotomy acute heart failure provides an opportunity to stabilize the patient's hemodynamic state while determining the best long-term strategy. Because all of these devices require anticoagulation treatment of various intensities, management of major bleeding can be critical for the overall outcome of the therapy. In this regard, the newest generation of magnetically levitated centrifugal-fl ow pumps affords several potential advantages in terms of thrombogenicity and eventual discontinuation of anticoagulation treatment. We report the use of a short-term biventricular assist device (Levitronix CentriMag) for 94 days in a 55-year-old man with refractory ventricular arrhythmias after combined heart surgery. Despite serious complications while the patient was on the assist device, including severe intestinal bleeding with the necessity of discontinuing anticoagulation for 10 days and, ultimately, hemicolectomy, the circulatory support was completed with successful heart transplantation.

AB - The use of short-term mechanical circulatory support during postcardiotomy acute heart failure provides an opportunity to stabilize the patient's hemodynamic state while determining the best long-term strategy. Because all of these devices require anticoagulation treatment of various intensities, management of major bleeding can be critical for the overall outcome of the therapy. In this regard, the newest generation of magnetically levitated centrifugal-fl ow pumps affords several potential advantages in terms of thrombogenicity and eventual discontinuation of anticoagulation treatment. We report the use of a short-term biventricular assist device (Levitronix CentriMag) for 94 days in a 55-year-old man with refractory ventricular arrhythmias after combined heart surgery. Despite serious complications while the patient was on the assist device, including severe intestinal bleeding with the necessity of discontinuing anticoagulation for 10 days and, ultimately, hemicolectomy, the circulatory support was completed with successful heart transplantation.

UR - http://www.scopus.com/inward/record.url?scp=78650590799&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=78650590799&partnerID=8YFLogxK

U2 - 10.1532/HSF98.20101068

DO - 10.1532/HSF98.20101068

M3 - Article

C2 - 21169156

AN - SCOPUS:78650590799

VL - 13

SP - E409-E410

JO - The heart surgery forum

JF - The heart surgery forum

SN - 1098-3511

IS - 6

ER -