Comparison of microCT and an inverse finite element approach for biomechanical analysis: Results in a mesenchymal stem cell therapeutic system for fracture healing

Jared A. Weis, Froilán Granero-Moltó, Timothy J. Myers, Lara Longobardi, Anna Spagnoli, Michael I. Miga

Research output: Contribution to journalArticle

4 Citations (Scopus)

Abstract

An important concern in the study of fracture healing is the ability to assess mechanical integrity in response to candidate therapeutics in small-animal systems. In recent reports, it has been proposed that microCT image-derived densitometric parameters could be used as a surrogate for mechanical property assessment. Recently, we have proposed an inverse methodology that iteratively reconstructs the modulus of elasticity of the lumped soft callus/hard callus region by integrating both intrinsic mechanical property (from biomechanical testing) and geometrical information (from microCT) within an inverse finite element analysis (FEA) to define a callus quality measure. In this paper, data from a therapeutic system involving mesenchymal stem cells is analyzed within the context of comparing traditional microCT densitometric and mechanical property metrics. In addition, a novel multi-parameter regression microCT parameter is analyzed as well as our inverse FEA metric. The results demonstrate that the inverse FEA approach was the only metric to successfully detect both longitudinal and therapeutic responses. While the most promising microCT-based metrics were adequate at early healing states, they failed to track late-stage mechanical integrity. In addition, our analysis added insight to the role of MSCs by demonstrating accelerated healing and was the only metric to demonstrate therapeutic benefits at late-stage healing. In conclusion, the work presented here indicates that microCT densitometric parameters are an incomplete surrogate for mechanical integrity. Additionally, our inverse FEA approach is shown to be very sensitive and may provide a first-step towards normalizing the often challenging process of assessing mechanical integrity of healing fractures.

Original languageEnglish (US)
Pages (from-to)2164-2170
Number of pages7
JournalJournal of Biomechanics
Volume45
Issue number12
DOIs
StatePublished - Aug 9 2012

Fingerprint

X-Ray Microtomography
Fracture Healing
Stem cells
Mesenchymal Stromal Cells
Finite Element Analysis
Finite element method
Bony Callus
Mechanical properties
Mechanical Phenomena
Therapeutics
Animals
Elastic Modulus
Elastic moduli
Testing

Keywords

  • Bone fracture healing
  • Finite element analysis
  • Material properties
  • Mesenchymal stem cells
  • MicroCT

ASJC Scopus subject areas

  • Biophysics
  • Orthopedics and Sports Medicine
  • Biomedical Engineering
  • Rehabilitation

Cite this

Comparison of microCT and an inverse finite element approach for biomechanical analysis : Results in a mesenchymal stem cell therapeutic system for fracture healing. / Weis, Jared A.; Granero-Moltó, Froilán; Myers, Timothy J.; Longobardi, Lara; Spagnoli, Anna; Miga, Michael I.

In: Journal of Biomechanics, Vol. 45, No. 12, 09.08.2012, p. 2164-2170.

Research output: Contribution to journalArticle

Weis, Jared A. ; Granero-Moltó, Froilán ; Myers, Timothy J. ; Longobardi, Lara ; Spagnoli, Anna ; Miga, Michael I. / Comparison of microCT and an inverse finite element approach for biomechanical analysis : Results in a mesenchymal stem cell therapeutic system for fracture healing. In: Journal of Biomechanics. 2012 ; Vol. 45, No. 12. pp. 2164-2170.
@article{f7130888abf0477197338767c9b5b169,
title = "Comparison of microCT and an inverse finite element approach for biomechanical analysis: Results in a mesenchymal stem cell therapeutic system for fracture healing",
abstract = "An important concern in the study of fracture healing is the ability to assess mechanical integrity in response to candidate therapeutics in small-animal systems. In recent reports, it has been proposed that microCT image-derived densitometric parameters could be used as a surrogate for mechanical property assessment. Recently, we have proposed an inverse methodology that iteratively reconstructs the modulus of elasticity of the lumped soft callus/hard callus region by integrating both intrinsic mechanical property (from biomechanical testing) and geometrical information (from microCT) within an inverse finite element analysis (FEA) to define a callus quality measure. In this paper, data from a therapeutic system involving mesenchymal stem cells is analyzed within the context of comparing traditional microCT densitometric and mechanical property metrics. In addition, a novel multi-parameter regression microCT parameter is analyzed as well as our inverse FEA metric. The results demonstrate that the inverse FEA approach was the only metric to successfully detect both longitudinal and therapeutic responses. While the most promising microCT-based metrics were adequate at early healing states, they failed to track late-stage mechanical integrity. In addition, our analysis added insight to the role of MSCs by demonstrating accelerated healing and was the only metric to demonstrate therapeutic benefits at late-stage healing. In conclusion, the work presented here indicates that microCT densitometric parameters are an incomplete surrogate for mechanical integrity. Additionally, our inverse FEA approach is shown to be very sensitive and may provide a first-step towards normalizing the often challenging process of assessing mechanical integrity of healing fractures.",
keywords = "Bone fracture healing, Finite element analysis, Material properties, Mesenchymal stem cells, MicroCT",
author = "Weis, {Jared A.} and Froil{\'a}n Granero-Molt{\'o} and Myers, {Timothy J.} and Lara Longobardi and Anna Spagnoli and Miga, {Michael I.}",
year = "2012",
month = "8",
day = "9",
doi = "10.1016/j.jbiomech.2012.05.033",
language = "English (US)",
volume = "45",
pages = "2164--2170",
journal = "Journal of Biomechanics",
issn = "0021-9290",
publisher = "Elsevier Limited",
number = "12",

}

TY - JOUR

T1 - Comparison of microCT and an inverse finite element approach for biomechanical analysis

T2 - Results in a mesenchymal stem cell therapeutic system for fracture healing

AU - Weis, Jared A.

AU - Granero-Moltó, Froilán

AU - Myers, Timothy J.

AU - Longobardi, Lara

AU - Spagnoli, Anna

AU - Miga, Michael I.

PY - 2012/8/9

Y1 - 2012/8/9

N2 - An important concern in the study of fracture healing is the ability to assess mechanical integrity in response to candidate therapeutics in small-animal systems. In recent reports, it has been proposed that microCT image-derived densitometric parameters could be used as a surrogate for mechanical property assessment. Recently, we have proposed an inverse methodology that iteratively reconstructs the modulus of elasticity of the lumped soft callus/hard callus region by integrating both intrinsic mechanical property (from biomechanical testing) and geometrical information (from microCT) within an inverse finite element analysis (FEA) to define a callus quality measure. In this paper, data from a therapeutic system involving mesenchymal stem cells is analyzed within the context of comparing traditional microCT densitometric and mechanical property metrics. In addition, a novel multi-parameter regression microCT parameter is analyzed as well as our inverse FEA metric. The results demonstrate that the inverse FEA approach was the only metric to successfully detect both longitudinal and therapeutic responses. While the most promising microCT-based metrics were adequate at early healing states, they failed to track late-stage mechanical integrity. In addition, our analysis added insight to the role of MSCs by demonstrating accelerated healing and was the only metric to demonstrate therapeutic benefits at late-stage healing. In conclusion, the work presented here indicates that microCT densitometric parameters are an incomplete surrogate for mechanical integrity. Additionally, our inverse FEA approach is shown to be very sensitive and may provide a first-step towards normalizing the often challenging process of assessing mechanical integrity of healing fractures.

AB - An important concern in the study of fracture healing is the ability to assess mechanical integrity in response to candidate therapeutics in small-animal systems. In recent reports, it has been proposed that microCT image-derived densitometric parameters could be used as a surrogate for mechanical property assessment. Recently, we have proposed an inverse methodology that iteratively reconstructs the modulus of elasticity of the lumped soft callus/hard callus region by integrating both intrinsic mechanical property (from biomechanical testing) and geometrical information (from microCT) within an inverse finite element analysis (FEA) to define a callus quality measure. In this paper, data from a therapeutic system involving mesenchymal stem cells is analyzed within the context of comparing traditional microCT densitometric and mechanical property metrics. In addition, a novel multi-parameter regression microCT parameter is analyzed as well as our inverse FEA metric. The results demonstrate that the inverse FEA approach was the only metric to successfully detect both longitudinal and therapeutic responses. While the most promising microCT-based metrics were adequate at early healing states, they failed to track late-stage mechanical integrity. In addition, our analysis added insight to the role of MSCs by demonstrating accelerated healing and was the only metric to demonstrate therapeutic benefits at late-stage healing. In conclusion, the work presented here indicates that microCT densitometric parameters are an incomplete surrogate for mechanical integrity. Additionally, our inverse FEA approach is shown to be very sensitive and may provide a first-step towards normalizing the often challenging process of assessing mechanical integrity of healing fractures.

KW - Bone fracture healing

KW - Finite element analysis

KW - Material properties

KW - Mesenchymal stem cells

KW - MicroCT

UR - http://www.scopus.com/inward/record.url?scp=84864113379&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84864113379&partnerID=8YFLogxK

U2 - 10.1016/j.jbiomech.2012.05.033

DO - 10.1016/j.jbiomech.2012.05.033

M3 - Article

C2 - 22766379

AN - SCOPUS:84864113379

VL - 45

SP - 2164

EP - 2170

JO - Journal of Biomechanics

JF - Journal of Biomechanics

SN - 0021-9290

IS - 12

ER -