Characterization and experimental results of a novel sensor for measuring the contact force from myenteric contractions

Benjamin S. Terry, Jonathan A. Schoen, Mark E. Rentschler

Research output: Contribution to journalArticle

11 Citations (Scopus)

Abstract

The intraluminal pressures and traction forces associated with the migrating motor complex are well understood; however, the contact forces directly exerted by the bowel wall on a solid, or near solid, bolus have not previously been measured. Quantifying contact forces is an important component to understanding the net force experienced by an in vivo robotic capsule endoscope. In this paper, we develop a novel sensor, the migrating motor complex force sensor (MFS), for measuring the contact force generated by the contracting myenteron of the small intestine. The MFS consists of a perfused manometer connected to four torus-shaped balloons custom formed of natural latex rubber and embedded with temperature and pressure sensors. Force exerted on the balloon causes sensor pressure change. In vivo, the MFS measures the magnitude and axial location of contact pressure exerted by the myenteron. The device is tested in vivo in a live porcine model on the middle small bowel. The mean total force per centimeter of axial length of intestine that occurred over a 16-min interval in vivo was 1.04 N·cm -1 in the middle region of the small intestine; the measured force is in the range of theoretical values.

Original languageEnglish (US)
Article number2195179
Pages (from-to)1971-1977
Number of pages7
JournalIEEE Transactions on Biomedical Engineering
Volume59
Issue number7
DOIs
StatePublished - Jun 29 2012

Fingerprint

Balloons
Sensors
Pressure sensors
Manometers
Endoscopy
Temperature sensors
Latexes
Rubber
Robotics

Keywords

  • Contact force
  • in vivo
  • migrating motor complex force sensor (MFS)
  • small intestine
  • solid bolus

ASJC Scopus subject areas

  • Biomedical Engineering

Cite this

Characterization and experimental results of a novel sensor for measuring the contact force from myenteric contractions. / Terry, Benjamin S.; Schoen, Jonathan A.; Rentschler, Mark E.

In: IEEE Transactions on Biomedical Engineering, Vol. 59, No. 7, 2195179, 29.06.2012, p. 1971-1977.

Research output: Contribution to journalArticle

@article{005d2a26eba14bde9fbb7a05c35e93c3,
title = "Characterization and experimental results of a novel sensor for measuring the contact force from myenteric contractions",
abstract = "The intraluminal pressures and traction forces associated with the migrating motor complex are well understood; however, the contact forces directly exerted by the bowel wall on a solid, or near solid, bolus have not previously been measured. Quantifying contact forces is an important component to understanding the net force experienced by an in vivo robotic capsule endoscope. In this paper, we develop a novel sensor, the migrating motor complex force sensor (MFS), for measuring the contact force generated by the contracting myenteron of the small intestine. The MFS consists of a perfused manometer connected to four torus-shaped balloons custom formed of natural latex rubber and embedded with temperature and pressure sensors. Force exerted on the balloon causes sensor pressure change. In vivo, the MFS measures the magnitude and axial location of contact pressure exerted by the myenteron. The device is tested in vivo in a live porcine model on the middle small bowel. The mean total force per centimeter of axial length of intestine that occurred over a 16-min interval in vivo was 1.04 N·cm -1 in the middle region of the small intestine; the measured force is in the range of theoretical values.",
keywords = "Contact force, in vivo, migrating motor complex force sensor (MFS), small intestine, solid bolus",
author = "Terry, {Benjamin S.} and Schoen, {Jonathan A.} and Rentschler, {Mark E.}",
year = "2012",
month = "6",
day = "29",
doi = "10.1109/TBME.2012.2195179",
language = "English (US)",
volume = "59",
pages = "1971--1977",
journal = "IEEE Transactions on Biomedical Engineering",
issn = "0018-9294",
publisher = "IEEE Computer Society",
number = "7",

}

TY - JOUR

T1 - Characterization and experimental results of a novel sensor for measuring the contact force from myenteric contractions

AU - Terry, Benjamin S.

AU - Schoen, Jonathan A.

AU - Rentschler, Mark E.

PY - 2012/6/29

Y1 - 2012/6/29

N2 - The intraluminal pressures and traction forces associated with the migrating motor complex are well understood; however, the contact forces directly exerted by the bowel wall on a solid, or near solid, bolus have not previously been measured. Quantifying contact forces is an important component to understanding the net force experienced by an in vivo robotic capsule endoscope. In this paper, we develop a novel sensor, the migrating motor complex force sensor (MFS), for measuring the contact force generated by the contracting myenteron of the small intestine. The MFS consists of a perfused manometer connected to four torus-shaped balloons custom formed of natural latex rubber and embedded with temperature and pressure sensors. Force exerted on the balloon causes sensor pressure change. In vivo, the MFS measures the magnitude and axial location of contact pressure exerted by the myenteron. The device is tested in vivo in a live porcine model on the middle small bowel. The mean total force per centimeter of axial length of intestine that occurred over a 16-min interval in vivo was 1.04 N·cm -1 in the middle region of the small intestine; the measured force is in the range of theoretical values.

AB - The intraluminal pressures and traction forces associated with the migrating motor complex are well understood; however, the contact forces directly exerted by the bowel wall on a solid, or near solid, bolus have not previously been measured. Quantifying contact forces is an important component to understanding the net force experienced by an in vivo robotic capsule endoscope. In this paper, we develop a novel sensor, the migrating motor complex force sensor (MFS), for measuring the contact force generated by the contracting myenteron of the small intestine. The MFS consists of a perfused manometer connected to four torus-shaped balloons custom formed of natural latex rubber and embedded with temperature and pressure sensors. Force exerted on the balloon causes sensor pressure change. In vivo, the MFS measures the magnitude and axial location of contact pressure exerted by the myenteron. The device is tested in vivo in a live porcine model on the middle small bowel. The mean total force per centimeter of axial length of intestine that occurred over a 16-min interval in vivo was 1.04 N·cm -1 in the middle region of the small intestine; the measured force is in the range of theoretical values.

KW - Contact force

KW - in vivo

KW - migrating motor complex force sensor (MFS)

KW - small intestine

KW - solid bolus

UR - http://www.scopus.com/inward/record.url?scp=84862739071&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84862739071&partnerID=8YFLogxK

U2 - 10.1109/TBME.2012.2195179

DO - 10.1109/TBME.2012.2195179

M3 - Article

C2 - 22531741

AN - SCOPUS:84862739071

VL - 59

SP - 1971

EP - 1977

JO - IEEE Transactions on Biomedical Engineering

JF - IEEE Transactions on Biomedical Engineering

SN - 0018-9294

IS - 7

M1 - 2195179

ER -