Cementless Acetabular Fixation in Patients 50 Years and Younger at 10 to 18 Years of Follow-Up

Matthew J Teusink, John J. Callaghan, Lucian C. Warth, Devon D. Goetz, Douglas R. Pedersen, Richard C. Johnston

Research output: Contribution to journalArticle

6 Citations (Scopus)

Abstract

The purpose of the study was to evaluate the 10- to 18-year follow-up of cementless acetabular fixation in patients 50 years and younger. We retrospectively reviewed a consecutive group of 118 patients (144 hips) in whom primary total hip arthroplasty had been performed by 2 surgeons using a cementless acetabular component. Two (1.4%) cementless acetabular components were revised because of aseptic loosening. Twenty-four hips (16.7%) were revised for any mechanical failure of the acetabular component mostly related to acetabular liner wear and osteolysis. The average linear wear rate was 0.19 mm per year, which was higher than our previous reports with cemented acetabular fixation. The fiber mesh ingrowth surface of the cementless acetabular component in this study was superior to cemented acetabular components in terms of fixation. However, the high rates of wear and osteolysis have led to poor overall acetabular component construct survivorship.

Original languageEnglish (US)
JournalJournal of Arthroplasty
Volume27
Issue number7
DOIs
StatePublished - Jan 1 2012

Fingerprint

Hip
Osteolysis
Arthroplasty
Survival Rate
Surgeons

Keywords

  • 50 years and younger
  • Bearing surface
  • Cementless acetabular fixation
  • Primary total hip arthroplasty
  • Young

ASJC Scopus subject areas

  • Orthopedics and Sports Medicine

Cite this

Cementless Acetabular Fixation in Patients 50 Years and Younger at 10 to 18 Years of Follow-Up. / Teusink, Matthew J; Callaghan, John J.; Warth, Lucian C.; Goetz, Devon D.; Pedersen, Douglas R.; Johnston, Richard C.

In: Journal of Arthroplasty, Vol. 27, No. 7, 01.01.2012.

Research output: Contribution to journalArticle

Teusink, Matthew J ; Callaghan, John J. ; Warth, Lucian C. ; Goetz, Devon D. ; Pedersen, Douglas R. ; Johnston, Richard C. / Cementless Acetabular Fixation in Patients 50 Years and Younger at 10 to 18 Years of Follow-Up. In: Journal of Arthroplasty. 2012 ; Vol. 27, No. 7.
@article{cc75cbe64d84459d84aa9c9fe2fb7c0a,
title = "Cementless Acetabular Fixation in Patients 50 Years and Younger at 10 to 18 Years of Follow-Up",
abstract = "The purpose of the study was to evaluate the 10- to 18-year follow-up of cementless acetabular fixation in patients 50 years and younger. We retrospectively reviewed a consecutive group of 118 patients (144 hips) in whom primary total hip arthroplasty had been performed by 2 surgeons using a cementless acetabular component. Two (1.4{\%}) cementless acetabular components were revised because of aseptic loosening. Twenty-four hips (16.7{\%}) were revised for any mechanical failure of the acetabular component mostly related to acetabular liner wear and osteolysis. The average linear wear rate was 0.19 mm per year, which was higher than our previous reports with cemented acetabular fixation. The fiber mesh ingrowth surface of the cementless acetabular component in this study was superior to cemented acetabular components in terms of fixation. However, the high rates of wear and osteolysis have led to poor overall acetabular component construct survivorship.",
keywords = "50 years and younger, Bearing surface, Cementless acetabular fixation, Primary total hip arthroplasty, Young",
author = "Teusink, {Matthew J} and Callaghan, {John J.} and Warth, {Lucian C.} and Goetz, {Devon D.} and Pedersen, {Douglas R.} and Johnston, {Richard C.}",
year = "2012",
month = "1",
day = "1",
doi = "10.1016/j.arth.2011.10.020",
language = "English (US)",
volume = "27",
journal = "Journal of Arthroplasty",
issn = "0883-5403",
publisher = "Churchill Livingstone",
number = "7",

}

TY - JOUR

T1 - Cementless Acetabular Fixation in Patients 50 Years and Younger at 10 to 18 Years of Follow-Up

AU - Teusink, Matthew J

AU - Callaghan, John J.

AU - Warth, Lucian C.

AU - Goetz, Devon D.

AU - Pedersen, Douglas R.

AU - Johnston, Richard C.

PY - 2012/1/1

Y1 - 2012/1/1

N2 - The purpose of the study was to evaluate the 10- to 18-year follow-up of cementless acetabular fixation in patients 50 years and younger. We retrospectively reviewed a consecutive group of 118 patients (144 hips) in whom primary total hip arthroplasty had been performed by 2 surgeons using a cementless acetabular component. Two (1.4%) cementless acetabular components were revised because of aseptic loosening. Twenty-four hips (16.7%) were revised for any mechanical failure of the acetabular component mostly related to acetabular liner wear and osteolysis. The average linear wear rate was 0.19 mm per year, which was higher than our previous reports with cemented acetabular fixation. The fiber mesh ingrowth surface of the cementless acetabular component in this study was superior to cemented acetabular components in terms of fixation. However, the high rates of wear and osteolysis have led to poor overall acetabular component construct survivorship.

AB - The purpose of the study was to evaluate the 10- to 18-year follow-up of cementless acetabular fixation in patients 50 years and younger. We retrospectively reviewed a consecutive group of 118 patients (144 hips) in whom primary total hip arthroplasty had been performed by 2 surgeons using a cementless acetabular component. Two (1.4%) cementless acetabular components were revised because of aseptic loosening. Twenty-four hips (16.7%) were revised for any mechanical failure of the acetabular component mostly related to acetabular liner wear and osteolysis. The average linear wear rate was 0.19 mm per year, which was higher than our previous reports with cemented acetabular fixation. The fiber mesh ingrowth surface of the cementless acetabular component in this study was superior to cemented acetabular components in terms of fixation. However, the high rates of wear and osteolysis have led to poor overall acetabular component construct survivorship.

KW - 50 years and younger

KW - Bearing surface

KW - Cementless acetabular fixation

KW - Primary total hip arthroplasty

KW - Young

UR - http://www.scopus.com/inward/record.url?scp=84864026096&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84864026096&partnerID=8YFLogxK

U2 - 10.1016/j.arth.2011.10.020

DO - 10.1016/j.arth.2011.10.020

M3 - Article

C2 - 22266047

AN - SCOPUS:84864026096

VL - 27

JO - Journal of Arthroplasty

JF - Journal of Arthroplasty

SN - 0883-5403

IS - 7

ER -