An optical bio-sensor is built based on an infrared chalcogenide fiber coated with live cells. The fiber is immersed in an aqueous media appropriate for cell viability. The response of the cells to small quantities of toxicant can be monitored spectroscopically. The properties of chalcogenide fibers used for cell-based biosensors are investigated. The chemical stability of Te-As-Se fibers in aqueous media is shown to depend on the previous storage time of the fiber. Older fibers are shown to generate an oxide layer during extended exposure to air. This layer readily dissolves in aqueous solution and causes the release of As in the cell environment. The release of As during dissolution of the oxide layer is measured with ICP-MS and is shown to be complete after a couple hours. Fresh fibers do not show any detectable oxide layer and show excellent stability in aqueous solution. The surface roughness of old and fresh fibers is investigated with AFM before and after dissolution in aqueous media. Old fibers immersed in solution show sizable roughness due to the oxide surface layer dissolution. Fresh fibers do not show any detectable changes even after extended immersion in aqueous solution. The toxicity of As to various types of vertebrate cells is quantified using a colorimetric assay. Old fibers are shown to be notably toxic due to As released during dissolution. The fiber toxicity is shown to decrease when the fibers are previously washed in solution. The toxicity of the resulting wash water is then shown to increase due to the increase in As concentration.

Original languageEnglish (US)
Title of host publicationProgress in Biomedical Optics and Imaging - Proceedings of SPIE
DOIs
StatePublished - May 8 2006
EventOptical Fibers and Sensors for Medical Diagnostics and Treatment Applications VI - San Jose, CA, United States
Duration: Jan 21 2006Jan 22 2006

Publication series

NameProgress in Biomedical Optics and Imaging - Proceedings of SPIE
Volume6083
ISSN (Print)1605-7422

Other

OtherOptical Fibers and Sensors for Medical Diagnostics and Treatment Applications VI
CountryUnited States
CitySan Jose, CA
Period1/21/061/22/06

Fingerprint

Optical sensors
Fibers
Dissolution
Toxicity
Oxides
Surface roughness
Chemical stability
Biosensors
Assays
Cells

Keywords

  • Arsenic toxicity
  • Bio-compatibility
  • Bio-sensor
  • Chalcogenide glass fiber
  • Corrosion
  • Evanescent wave
  • Human lung cell
  • IR spectroscopy

ASJC Scopus subject areas

  • Engineering(all)

Cite this

Lucas, P., Wilhelm, A. A., Riley, M. R., Derosa, D. L., & Collier, J. M. (2006). Cell-based bio-optical sensors using chalcogenide fibers. In Progress in Biomedical Optics and Imaging - Proceedings of SPIE [60830W] (Progress in Biomedical Optics and Imaging - Proceedings of SPIE; Vol. 6083). https://doi.org/10.1117/12.654510

Cell-based bio-optical sensors using chalcogenide fibers. / Lucas, Pierre; Wilhelm, Allison A.; Riley, Mark R.; Derosa, Diana L.; Collier, Jayne M.

Progress in Biomedical Optics and Imaging - Proceedings of SPIE. 2006. 60830W (Progress in Biomedical Optics and Imaging - Proceedings of SPIE; Vol. 6083).

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Lucas, P, Wilhelm, AA, Riley, MR, Derosa, DL & Collier, JM 2006, Cell-based bio-optical sensors using chalcogenide fibers. in Progress in Biomedical Optics and Imaging - Proceedings of SPIE., 60830W, Progress in Biomedical Optics and Imaging - Proceedings of SPIE, vol. 6083, Optical Fibers and Sensors for Medical Diagnostics and Treatment Applications VI, San Jose, CA, United States, 1/21/06. https://doi.org/10.1117/12.654510
Lucas P, Wilhelm AA, Riley MR, Derosa DL, Collier JM. Cell-based bio-optical sensors using chalcogenide fibers. In Progress in Biomedical Optics and Imaging - Proceedings of SPIE. 2006. 60830W. (Progress in Biomedical Optics and Imaging - Proceedings of SPIE). https://doi.org/10.1117/12.654510
Lucas, Pierre ; Wilhelm, Allison A. ; Riley, Mark R. ; Derosa, Diana L. ; Collier, Jayne M. / Cell-based bio-optical sensors using chalcogenide fibers. Progress in Biomedical Optics and Imaging - Proceedings of SPIE. 2006. (Progress in Biomedical Optics and Imaging - Proceedings of SPIE).
@inproceedings{267d71279681411da25506f4b64a9784,
title = "Cell-based bio-optical sensors using chalcogenide fibers",
abstract = "An optical bio-sensor is built based on an infrared chalcogenide fiber coated with live cells. The fiber is immersed in an aqueous media appropriate for cell viability. The response of the cells to small quantities of toxicant can be monitored spectroscopically. The properties of chalcogenide fibers used for cell-based biosensors are investigated. The chemical stability of Te-As-Se fibers in aqueous media is shown to depend on the previous storage time of the fiber. Older fibers are shown to generate an oxide layer during extended exposure to air. This layer readily dissolves in aqueous solution and causes the release of As in the cell environment. The release of As during dissolution of the oxide layer is measured with ICP-MS and is shown to be complete after a couple hours. Fresh fibers do not show any detectable oxide layer and show excellent stability in aqueous solution. The surface roughness of old and fresh fibers is investigated with AFM before and after dissolution in aqueous media. Old fibers immersed in solution show sizable roughness due to the oxide surface layer dissolution. Fresh fibers do not show any detectable changes even after extended immersion in aqueous solution. The toxicity of As to various types of vertebrate cells is quantified using a colorimetric assay. Old fibers are shown to be notably toxic due to As released during dissolution. The fiber toxicity is shown to decrease when the fibers are previously washed in solution. The toxicity of the resulting wash water is then shown to increase due to the increase in As concentration.",
keywords = "Arsenic toxicity, Bio-compatibility, Bio-sensor, Chalcogenide glass fiber, Corrosion, Evanescent wave, Human lung cell, IR spectroscopy",
author = "Pierre Lucas and Wilhelm, {Allison A.} and Riley, {Mark R.} and Derosa, {Diana L.} and Collier, {Jayne M.}",
year = "2006",
month = "5",
day = "8",
doi = "10.1117/12.654510",
language = "English (US)",
isbn = "0819461253",
series = "Progress in Biomedical Optics and Imaging - Proceedings of SPIE",
booktitle = "Progress in Biomedical Optics and Imaging - Proceedings of SPIE",

}

TY - GEN

T1 - Cell-based bio-optical sensors using chalcogenide fibers

AU - Lucas, Pierre

AU - Wilhelm, Allison A.

AU - Riley, Mark R.

AU - Derosa, Diana L.

AU - Collier, Jayne M.

PY - 2006/5/8

Y1 - 2006/5/8

N2 - An optical bio-sensor is built based on an infrared chalcogenide fiber coated with live cells. The fiber is immersed in an aqueous media appropriate for cell viability. The response of the cells to small quantities of toxicant can be monitored spectroscopically. The properties of chalcogenide fibers used for cell-based biosensors are investigated. The chemical stability of Te-As-Se fibers in aqueous media is shown to depend on the previous storage time of the fiber. Older fibers are shown to generate an oxide layer during extended exposure to air. This layer readily dissolves in aqueous solution and causes the release of As in the cell environment. The release of As during dissolution of the oxide layer is measured with ICP-MS and is shown to be complete after a couple hours. Fresh fibers do not show any detectable oxide layer and show excellent stability in aqueous solution. The surface roughness of old and fresh fibers is investigated with AFM before and after dissolution in aqueous media. Old fibers immersed in solution show sizable roughness due to the oxide surface layer dissolution. Fresh fibers do not show any detectable changes even after extended immersion in aqueous solution. The toxicity of As to various types of vertebrate cells is quantified using a colorimetric assay. Old fibers are shown to be notably toxic due to As released during dissolution. The fiber toxicity is shown to decrease when the fibers are previously washed in solution. The toxicity of the resulting wash water is then shown to increase due to the increase in As concentration.

AB - An optical bio-sensor is built based on an infrared chalcogenide fiber coated with live cells. The fiber is immersed in an aqueous media appropriate for cell viability. The response of the cells to small quantities of toxicant can be monitored spectroscopically. The properties of chalcogenide fibers used for cell-based biosensors are investigated. The chemical stability of Te-As-Se fibers in aqueous media is shown to depend on the previous storage time of the fiber. Older fibers are shown to generate an oxide layer during extended exposure to air. This layer readily dissolves in aqueous solution and causes the release of As in the cell environment. The release of As during dissolution of the oxide layer is measured with ICP-MS and is shown to be complete after a couple hours. Fresh fibers do not show any detectable oxide layer and show excellent stability in aqueous solution. The surface roughness of old and fresh fibers is investigated with AFM before and after dissolution in aqueous media. Old fibers immersed in solution show sizable roughness due to the oxide surface layer dissolution. Fresh fibers do not show any detectable changes even after extended immersion in aqueous solution. The toxicity of As to various types of vertebrate cells is quantified using a colorimetric assay. Old fibers are shown to be notably toxic due to As released during dissolution. The fiber toxicity is shown to decrease when the fibers are previously washed in solution. The toxicity of the resulting wash water is then shown to increase due to the increase in As concentration.

KW - Arsenic toxicity

KW - Bio-compatibility

KW - Bio-sensor

KW - Chalcogenide glass fiber

KW - Corrosion

KW - Evanescent wave

KW - Human lung cell

KW - IR spectroscopy

UR - http://www.scopus.com/inward/record.url?scp=33646194600&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=33646194600&partnerID=8YFLogxK

U2 - 10.1117/12.654510

DO - 10.1117/12.654510

M3 - Conference contribution

AN - SCOPUS:33646194600

SN - 0819461253

SN - 9780819461254

T3 - Progress in Biomedical Optics and Imaging - Proceedings of SPIE

BT - Progress in Biomedical Optics and Imaging - Proceedings of SPIE

ER -