Objectives. A bonding agent has recently been introduced that prepares the surface of milled titanium copings for bonding to low fusing dental porcelains. This study evaluated the effectiveness of the bonding agent by comparing the shear and three-point bending strength of specimens made with three combinations of materials: 1) milled titanium/porcelain with bonding agent, 2) the same milled titanium/porcelain without bonding agent, and 3) cast high palladium/conventional porcelain. Methods. Shear specimens consisting of porcelain cylinders 6 mm in diameter and 8 mm in length were fired to the ends of metal cylinders 6 mm in diameter and 13 mm in length. Three-point bend specimens made of 25 × 3 × 0.5 mm metal bars were veneered with 8 × 3 × 1 mm of porcelain in the bar's center. Specimens were tested in shear and bending in a universal testing machine. The data were analyzed using one-way ANOVA and Newman-Kuels post hoc tests (p = 0.05). Results. When a titanium bonding agent was used, porcelain to titanium bond strength was slightly but statistically significantly greater than the porcelain to high palladium bond strength. The result was the same when measured by both shear and three-point bending tests. Without the bonding agent, the shear strength of porcelain to titanium was significantly lower than that of the bonding agent and high palladium groups. Significance. The use of a bonding agent improves the bond strength of porcelain-fused-to-milled titanium.

Original languageEnglish (US)
Pages (from-to)134-140
Number of pages7
JournalDental Materials
Volume10
Issue number2
DOIs
StatePublished - Jan 1 1994

Fingerprint

Dental Porcelain
Porcelain
Titanium
Palladium
Bond strength (materials)
Metals
Shear Strength
Bending tests
Analysis of variance (ANOVA)
Shear strength
Bending strength
Analysis of Variance

ASJC Scopus subject areas

  • Dentistry(all)

Cite this

Gilbert, J. L., Covey, D. A., & Lautenschlager, E. P. (1994). Bond characteristics of porcelain fused to milled titanium. Dental Materials, 10(2), 134-140. https://doi.org/10.1016/0109-5641(94)90054-X

Bond characteristics of porcelain fused to milled titanium. / Gilbert, Jeremy L.; Covey, David A; Lautenschlager, Eugene P.

In: Dental Materials, Vol. 10, No. 2, 01.01.1994, p. 134-140.

Research output: Contribution to journalArticle

Gilbert, JL, Covey, DA & Lautenschlager, EP 1994, 'Bond characteristics of porcelain fused to milled titanium', Dental Materials, vol. 10, no. 2, pp. 134-140. https://doi.org/10.1016/0109-5641(94)90054-X
Gilbert, Jeremy L. ; Covey, David A ; Lautenschlager, Eugene P. / Bond characteristics of porcelain fused to milled titanium. In: Dental Materials. 1994 ; Vol. 10, No. 2. pp. 134-140.
@article{e0f2f1bf14bb4de18cfab4ff0261b897,
title = "Bond characteristics of porcelain fused to milled titanium",
abstract = "Objectives. A bonding agent has recently been introduced that prepares the surface of milled titanium copings for bonding to low fusing dental porcelains. This study evaluated the effectiveness of the bonding agent by comparing the shear and three-point bending strength of specimens made with three combinations of materials: 1) milled titanium/porcelain with bonding agent, 2) the same milled titanium/porcelain without bonding agent, and 3) cast high palladium/conventional porcelain. Methods. Shear specimens consisting of porcelain cylinders 6 mm in diameter and 8 mm in length were fired to the ends of metal cylinders 6 mm in diameter and 13 mm in length. Three-point bend specimens made of 25 × 3 × 0.5 mm metal bars were veneered with 8 × 3 × 1 mm of porcelain in the bar's center. Specimens were tested in shear and bending in a universal testing machine. The data were analyzed using one-way ANOVA and Newman-Kuels post hoc tests (p = 0.05). Results. When a titanium bonding agent was used, porcelain to titanium bond strength was slightly but statistically significantly greater than the porcelain to high palladium bond strength. The result was the same when measured by both shear and three-point bending tests. Without the bonding agent, the shear strength of porcelain to titanium was significantly lower than that of the bonding agent and high palladium groups. Significance. The use of a bonding agent improves the bond strength of porcelain-fused-to-milled titanium.",
author = "Gilbert, {Jeremy L.} and Covey, {David A} and Lautenschlager, {Eugene P.}",
year = "1994",
month = "1",
day = "1",
doi = "10.1016/0109-5641(94)90054-X",
language = "English (US)",
volume = "10",
pages = "134--140",
journal = "Dental Materials",
issn = "0109-5641",
publisher = "Elsevier Science",
number = "2",

}

TY - JOUR

T1 - Bond characteristics of porcelain fused to milled titanium

AU - Gilbert, Jeremy L.

AU - Covey, David A

AU - Lautenschlager, Eugene P.

PY - 1994/1/1

Y1 - 1994/1/1

N2 - Objectives. A bonding agent has recently been introduced that prepares the surface of milled titanium copings for bonding to low fusing dental porcelains. This study evaluated the effectiveness of the bonding agent by comparing the shear and three-point bending strength of specimens made with three combinations of materials: 1) milled titanium/porcelain with bonding agent, 2) the same milled titanium/porcelain without bonding agent, and 3) cast high palladium/conventional porcelain. Methods. Shear specimens consisting of porcelain cylinders 6 mm in diameter and 8 mm in length were fired to the ends of metal cylinders 6 mm in diameter and 13 mm in length. Three-point bend specimens made of 25 × 3 × 0.5 mm metal bars were veneered with 8 × 3 × 1 mm of porcelain in the bar's center. Specimens were tested in shear and bending in a universal testing machine. The data were analyzed using one-way ANOVA and Newman-Kuels post hoc tests (p = 0.05). Results. When a titanium bonding agent was used, porcelain to titanium bond strength was slightly but statistically significantly greater than the porcelain to high palladium bond strength. The result was the same when measured by both shear and three-point bending tests. Without the bonding agent, the shear strength of porcelain to titanium was significantly lower than that of the bonding agent and high palladium groups. Significance. The use of a bonding agent improves the bond strength of porcelain-fused-to-milled titanium.

AB - Objectives. A bonding agent has recently been introduced that prepares the surface of milled titanium copings for bonding to low fusing dental porcelains. This study evaluated the effectiveness of the bonding agent by comparing the shear and three-point bending strength of specimens made with three combinations of materials: 1) milled titanium/porcelain with bonding agent, 2) the same milled titanium/porcelain without bonding agent, and 3) cast high palladium/conventional porcelain. Methods. Shear specimens consisting of porcelain cylinders 6 mm in diameter and 8 mm in length were fired to the ends of metal cylinders 6 mm in diameter and 13 mm in length. Three-point bend specimens made of 25 × 3 × 0.5 mm metal bars were veneered with 8 × 3 × 1 mm of porcelain in the bar's center. Specimens were tested in shear and bending in a universal testing machine. The data were analyzed using one-way ANOVA and Newman-Kuels post hoc tests (p = 0.05). Results. When a titanium bonding agent was used, porcelain to titanium bond strength was slightly but statistically significantly greater than the porcelain to high palladium bond strength. The result was the same when measured by both shear and three-point bending tests. Without the bonding agent, the shear strength of porcelain to titanium was significantly lower than that of the bonding agent and high palladium groups. Significance. The use of a bonding agent improves the bond strength of porcelain-fused-to-milled titanium.

UR - http://www.scopus.com/inward/record.url?scp=0028402743&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0028402743&partnerID=8YFLogxK

U2 - 10.1016/0109-5641(94)90054-X

DO - 10.1016/0109-5641(94)90054-X

M3 - Article

VL - 10

SP - 134

EP - 140

JO - Dental Materials

JF - Dental Materials

SN - 0109-5641

IS - 2

ER -