Balloon pump support of the failing right heart

Jeffrey P Gold, R. J. Shemin, V. J. Disesa, L. Cohn, J. J. Collins

Research output: Contribution to journalArticle

1 Citation (Scopus)

Abstract

This report reviews a clinical experience with pulmonary artery counterpulsation with a balloon pump in a patient with pulmonary embolization superimposed upon severe trivalvular rheumatic heart disease. This patient underwent a pulmonary embolectomy and triplevalve replacement requiring a pulmonary artery balloon pump for bypass discontinuation and postbypass hemo‐ynamic support. The field of right heart counterpulsation is briefly reviewed, and the technical details of the implantation and management of the device are elaborated.

Original languageEnglish (US)
Pages (from-to)599-602
Number of pages4
JournalClinical Cardiology
Volume8
Issue number11
DOIs
StatePublished - Jan 1 1985

Fingerprint

Counterpulsation
Pulmonary Artery
Embolectomy
Rheumatic Heart Disease
Lung
Equipment and Supplies

Keywords

  • balloon pump
  • right heart failure

ASJC Scopus subject areas

  • Cardiology and Cardiovascular Medicine

Cite this

Gold, J. P., Shemin, R. J., Disesa, V. J., Cohn, L., & Collins, J. J. (1985). Balloon pump support of the failing right heart. Clinical Cardiology, 8(11), 599-602. https://doi.org/10.1002/clc.4960081110

Balloon pump support of the failing right heart. / Gold, Jeffrey P; Shemin, R. J.; Disesa, V. J.; Cohn, L.; Collins, J. J.

In: Clinical Cardiology, Vol. 8, No. 11, 01.01.1985, p. 599-602.

Research output: Contribution to journalArticle

Gold, JP, Shemin, RJ, Disesa, VJ, Cohn, L & Collins, JJ 1985, 'Balloon pump support of the failing right heart', Clinical Cardiology, vol. 8, no. 11, pp. 599-602. https://doi.org/10.1002/clc.4960081110
Gold JP, Shemin RJ, Disesa VJ, Cohn L, Collins JJ. Balloon pump support of the failing right heart. Clinical Cardiology. 1985 Jan 1;8(11):599-602. https://doi.org/10.1002/clc.4960081110
Gold, Jeffrey P ; Shemin, R. J. ; Disesa, V. J. ; Cohn, L. ; Collins, J. J. / Balloon pump support of the failing right heart. In: Clinical Cardiology. 1985 ; Vol. 8, No. 11. pp. 599-602.
@article{c3f5e8db0cbc48e3a67ecee7ceac0c07,
title = "Balloon pump support of the failing right heart",
abstract = "This report reviews a clinical experience with pulmonary artery counterpulsation with a balloon pump in a patient with pulmonary embolization superimposed upon severe trivalvular rheumatic heart disease. This patient underwent a pulmonary embolectomy and triplevalve replacement requiring a pulmonary artery balloon pump for bypass discontinuation and postbypass hemo‐ynamic support. The field of right heart counterpulsation is briefly reviewed, and the technical details of the implantation and management of the device are elaborated.",
keywords = "balloon pump, right heart failure",
author = "Gold, {Jeffrey P} and Shemin, {R. J.} and Disesa, {V. J.} and L. Cohn and Collins, {J. J.}",
year = "1985",
month = "1",
day = "1",
doi = "10.1002/clc.4960081110",
language = "English (US)",
volume = "8",
pages = "599--602",
journal = "Clinical Cardiology",
issn = "0160-9289",
publisher = "John Wiley and Sons Inc.",
number = "11",

}

TY - JOUR

T1 - Balloon pump support of the failing right heart

AU - Gold, Jeffrey P

AU - Shemin, R. J.

AU - Disesa, V. J.

AU - Cohn, L.

AU - Collins, J. J.

PY - 1985/1/1

Y1 - 1985/1/1

N2 - This report reviews a clinical experience with pulmonary artery counterpulsation with a balloon pump in a patient with pulmonary embolization superimposed upon severe trivalvular rheumatic heart disease. This patient underwent a pulmonary embolectomy and triplevalve replacement requiring a pulmonary artery balloon pump for bypass discontinuation and postbypass hemo‐ynamic support. The field of right heart counterpulsation is briefly reviewed, and the technical details of the implantation and management of the device are elaborated.

AB - This report reviews a clinical experience with pulmonary artery counterpulsation with a balloon pump in a patient with pulmonary embolization superimposed upon severe trivalvular rheumatic heart disease. This patient underwent a pulmonary embolectomy and triplevalve replacement requiring a pulmonary artery balloon pump for bypass discontinuation and postbypass hemo‐ynamic support. The field of right heart counterpulsation is briefly reviewed, and the technical details of the implantation and management of the device are elaborated.

KW - balloon pump

KW - right heart failure

UR - http://www.scopus.com/inward/record.url?scp=0022403445&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0022403445&partnerID=8YFLogxK

U2 - 10.1002/clc.4960081110

DO - 10.1002/clc.4960081110

M3 - Article

VL - 8

SP - 599

EP - 602

JO - Clinical Cardiology

JF - Clinical Cardiology

SN - 0160-9289

IS - 11

ER -