Automated IVUS contour detection using intensity features and Radial Basis Function approximation

Maria Papadogiorgaki, Vasileios Mezaris, Ioannis S Chatzizisis, George D. Giannoglou, Ioannis Kompatsiaris

Research output: Chapter in Book/Report/Conference proceedingConference contribution

7 Citations (Scopus)

Abstract

Intravascular ultrasound (IVUS) constitutes a valuable technique for the diagnosis and management of coronary atherosclerosis. The detection of lumen and media-adventitia borders in IVUS images represents a necessary step in the utilization of the IVUS data for the reliable quantitative assessment of atherosclerotic lesions. In this paper, a fully automated technique for the detection of lumen and media-adventitia boundaries is developed. This comprises two different steps for contour initialization, one for each corresponding contour of interest, and a procedure for the refinement of the detected contours based on Radial Basis Function approximation. The proposed approach is shown to be capable of performing quick and reliable automated segmentation of IVUS images.

Original languageEnglish (US)
Title of host publicationProceedings - Twentieth IEEE International Symposium on Computer-Based Medical Systems, CBMS'07
Pages183-188
Number of pages6
DOIs
StatePublished - Oct 1 2007
Event20th IEEE International Symposium on Computer-Based Medical Systems, CBMS'07 - Maribor, Slovenia
Duration: Jun 20 2007Jun 22 2007

Publication series

NameProceedings - IEEE Symposium on Computer-Based Medical Systems
ISSN (Print)1063-7125

Conference

Conference20th IEEE International Symposium on Computer-Based Medical Systems, CBMS'07
CountrySlovenia
CityMaribor
Period6/20/076/22/07

Fingerprint

Ultrasonics

ASJC Scopus subject areas

  • Radiology Nuclear Medicine and imaging
  • Computer Science Applications

Cite this

Papadogiorgaki, M., Mezaris, V., Chatzizisis, I. S., Giannoglou, G. D., & Kompatsiaris, I. (2007). Automated IVUS contour detection using intensity features and Radial Basis Function approximation. In Proceedings - Twentieth IEEE International Symposium on Computer-Based Medical Systems, CBMS'07 (pp. 183-188). [4262647] (Proceedings - IEEE Symposium on Computer-Based Medical Systems). https://doi.org/10.1109/CBMS.2007.27

Automated IVUS contour detection using intensity features and Radial Basis Function approximation. / Papadogiorgaki, Maria; Mezaris, Vasileios; Chatzizisis, Ioannis S; Giannoglou, George D.; Kompatsiaris, Ioannis.

Proceedings - Twentieth IEEE International Symposium on Computer-Based Medical Systems, CBMS'07. 2007. p. 183-188 4262647 (Proceedings - IEEE Symposium on Computer-Based Medical Systems).

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Papadogiorgaki, M, Mezaris, V, Chatzizisis, IS, Giannoglou, GD & Kompatsiaris, I 2007, Automated IVUS contour detection using intensity features and Radial Basis Function approximation. in Proceedings - Twentieth IEEE International Symposium on Computer-Based Medical Systems, CBMS'07., 4262647, Proceedings - IEEE Symposium on Computer-Based Medical Systems, pp. 183-188, 20th IEEE International Symposium on Computer-Based Medical Systems, CBMS'07, Maribor, Slovenia, 6/20/07. https://doi.org/10.1109/CBMS.2007.27
Papadogiorgaki M, Mezaris V, Chatzizisis IS, Giannoglou GD, Kompatsiaris I. Automated IVUS contour detection using intensity features and Radial Basis Function approximation. In Proceedings - Twentieth IEEE International Symposium on Computer-Based Medical Systems, CBMS'07. 2007. p. 183-188. 4262647. (Proceedings - IEEE Symposium on Computer-Based Medical Systems). https://doi.org/10.1109/CBMS.2007.27
Papadogiorgaki, Maria ; Mezaris, Vasileios ; Chatzizisis, Ioannis S ; Giannoglou, George D. ; Kompatsiaris, Ioannis. / Automated IVUS contour detection using intensity features and Radial Basis Function approximation. Proceedings - Twentieth IEEE International Symposium on Computer-Based Medical Systems, CBMS'07. 2007. pp. 183-188 (Proceedings - IEEE Symposium on Computer-Based Medical Systems).
@inproceedings{ee0a404fae5a4363bb73a15bfdf0ae56,
title = "Automated IVUS contour detection using intensity features and Radial Basis Function approximation",
abstract = "Intravascular ultrasound (IVUS) constitutes a valuable technique for the diagnosis and management of coronary atherosclerosis. The detection of lumen and media-adventitia borders in IVUS images represents a necessary step in the utilization of the IVUS data for the reliable quantitative assessment of atherosclerotic lesions. In this paper, a fully automated technique for the detection of lumen and media-adventitia boundaries is developed. This comprises two different steps for contour initialization, one for each corresponding contour of interest, and a procedure for the refinement of the detected contours based on Radial Basis Function approximation. The proposed approach is shown to be capable of performing quick and reliable automated segmentation of IVUS images.",
author = "Maria Papadogiorgaki and Vasileios Mezaris and Chatzizisis, {Ioannis S} and Giannoglou, {George D.} and Ioannis Kompatsiaris",
year = "2007",
month = "10",
day = "1",
doi = "10.1109/CBMS.2007.27",
language = "English (US)",
isbn = "0769529054",
series = "Proceedings - IEEE Symposium on Computer-Based Medical Systems",
pages = "183--188",
booktitle = "Proceedings - Twentieth IEEE International Symposium on Computer-Based Medical Systems, CBMS'07",

}

TY - GEN

T1 - Automated IVUS contour detection using intensity features and Radial Basis Function approximation

AU - Papadogiorgaki, Maria

AU - Mezaris, Vasileios

AU - Chatzizisis, Ioannis S

AU - Giannoglou, George D.

AU - Kompatsiaris, Ioannis

PY - 2007/10/1

Y1 - 2007/10/1

N2 - Intravascular ultrasound (IVUS) constitutes a valuable technique for the diagnosis and management of coronary atherosclerosis. The detection of lumen and media-adventitia borders in IVUS images represents a necessary step in the utilization of the IVUS data for the reliable quantitative assessment of atherosclerotic lesions. In this paper, a fully automated technique for the detection of lumen and media-adventitia boundaries is developed. This comprises two different steps for contour initialization, one for each corresponding contour of interest, and a procedure for the refinement of the detected contours based on Radial Basis Function approximation. The proposed approach is shown to be capable of performing quick and reliable automated segmentation of IVUS images.

AB - Intravascular ultrasound (IVUS) constitutes a valuable technique for the diagnosis and management of coronary atherosclerosis. The detection of lumen and media-adventitia borders in IVUS images represents a necessary step in the utilization of the IVUS data for the reliable quantitative assessment of atherosclerotic lesions. In this paper, a fully automated technique for the detection of lumen and media-adventitia boundaries is developed. This comprises two different steps for contour initialization, one for each corresponding contour of interest, and a procedure for the refinement of the detected contours based on Radial Basis Function approximation. The proposed approach is shown to be capable of performing quick and reliable automated segmentation of IVUS images.

UR - http://www.scopus.com/inward/record.url?scp=34748905877&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=34748905877&partnerID=8YFLogxK

U2 - 10.1109/CBMS.2007.27

DO - 10.1109/CBMS.2007.27

M3 - Conference contribution

SN - 0769529054

SN - 9780769529059

T3 - Proceedings - IEEE Symposium on Computer-Based Medical Systems

SP - 183

EP - 188

BT - Proceedings - Twentieth IEEE International Symposium on Computer-Based Medical Systems, CBMS'07

ER -