Assay for etoposide in human serum using solid-phase extraction and high-performance liquid chromatography with fluorescence detection

Konstantine K. Manouilov, Timothy R McGuire, Bruce Geoffrey Gordon, Peter R. Gwilt

Research output: Contribution to journalArticle

18 Citations (Scopus)

Abstract

An HPLC assay for etoposide in human serum was developed. Serum, spiked with podophyllotoxin (internal standard), was treated with sodium dodecyl sulphate prior to solid phase extraction. Analysis was performed on a 300 x 3.9 mm Bondclone 10 C18 column coupled with a fluorometric detector (λ(ex) 230 nm, λ(em) 330 nm). The retention times for etoposide and podophyllotoxin were 14 and 28 min respectively. The range of assay was 0.5 to 20 μg/ml with a detection limit of 0.2 μg/ml. This assay is suitable for use in clinical studies with etoposide.

Original languageEnglish (US)
Pages (from-to)342-346
Number of pages5
JournalJournal of Chromatography B: Biomedical Applications
Volume707
Issue number1-2
DOIs
StatePublished - Apr 10 1998

Fingerprint

High performance liquid chromatography
Etoposide
Podophyllotoxin
Assays
Fluorescence
Sodium Dodecyl Sulfate
Detectors

Keywords

  • Etoposide

ASJC Scopus subject areas

  • Chemistry(all)

Cite this

@article{e9e6ba6a21db465abea2a81d23516298,
title = "Assay for etoposide in human serum using solid-phase extraction and high-performance liquid chromatography with fluorescence detection",
abstract = "An HPLC assay for etoposide in human serum was developed. Serum, spiked with podophyllotoxin (internal standard), was treated with sodium dodecyl sulphate prior to solid phase extraction. Analysis was performed on a 300 x 3.9 mm Bondclone 10 C18 column coupled with a fluorometric detector (λ(ex) 230 nm, λ(em) 330 nm). The retention times for etoposide and podophyllotoxin were 14 and 28 min respectively. The range of assay was 0.5 to 20 μg/ml with a detection limit of 0.2 μg/ml. This assay is suitable for use in clinical studies with etoposide.",
keywords = "Etoposide",
author = "Manouilov, {Konstantine K.} and McGuire, {Timothy R} and Gordon, {Bruce Geoffrey} and Gwilt, {Peter R.}",
year = "1998",
month = "4",
day = "10",
doi = "10.1016/S0378-4347(97)00543-4",
language = "English (US)",
volume = "707",
pages = "342--346",
journal = "Journal of Chromatography B: Biomedical Sciences and Applications",
issn = "0378-4347",
publisher = "Elsevier BV",
number = "1-2",

}

TY - JOUR

T1 - Assay for etoposide in human serum using solid-phase extraction and high-performance liquid chromatography with fluorescence detection

AU - Manouilov, Konstantine K.

AU - McGuire, Timothy R

AU - Gordon, Bruce Geoffrey

AU - Gwilt, Peter R.

PY - 1998/4/10

Y1 - 1998/4/10

N2 - An HPLC assay for etoposide in human serum was developed. Serum, spiked with podophyllotoxin (internal standard), was treated with sodium dodecyl sulphate prior to solid phase extraction. Analysis was performed on a 300 x 3.9 mm Bondclone 10 C18 column coupled with a fluorometric detector (λ(ex) 230 nm, λ(em) 330 nm). The retention times for etoposide and podophyllotoxin were 14 and 28 min respectively. The range of assay was 0.5 to 20 μg/ml with a detection limit of 0.2 μg/ml. This assay is suitable for use in clinical studies with etoposide.

AB - An HPLC assay for etoposide in human serum was developed. Serum, spiked with podophyllotoxin (internal standard), was treated with sodium dodecyl sulphate prior to solid phase extraction. Analysis was performed on a 300 x 3.9 mm Bondclone 10 C18 column coupled with a fluorometric detector (λ(ex) 230 nm, λ(em) 330 nm). The retention times for etoposide and podophyllotoxin were 14 and 28 min respectively. The range of assay was 0.5 to 20 μg/ml with a detection limit of 0.2 μg/ml. This assay is suitable for use in clinical studies with etoposide.

KW - Etoposide

UR - http://www.scopus.com/inward/record.url?scp=0032503034&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0032503034&partnerID=8YFLogxK

U2 - 10.1016/S0378-4347(97)00543-4

DO - 10.1016/S0378-4347(97)00543-4

M3 - Article

C2 - 9613971

AN - SCOPUS:0032503034

VL - 707

SP - 342

EP - 346

JO - Journal of Chromatography B: Biomedical Sciences and Applications

JF - Journal of Chromatography B: Biomedical Sciences and Applications

SN - 0378-4347

IS - 1-2

ER -