Background: The authors' previous study showed a closed-loop chip system that was used to control arterial pressure in normal rabbits and rats. In the present study the anti-hypertensive effects of the chip system were investigated in anaesthetized two-kidney one-clip (2K1C) renovascular hypertensive rats and compared with sham-operated rats. Material/Methods: The chip system recorded, sampled, and processed the signals of arterial pressure and instantaneously controlled arterial pressure by stimulating the left aortic depressor nerve. The frequency of stimulation was determined according to the feedback signals of arterial pressure. Results: The chip system, running three different programs, successfully achieved a different degree of depressor effects. It effectively decreased not only mean arterial pressure (MAP), but also renal sympathetic nerve activity (RSNA) in both 2K1C rats and sham-operated rats. The chip system significantly increased the baroreflex gain in the 2K1C rats, but not in the sham-operated rats. It normalized the increased left ventricle developing pressure and maximal rise rate of the left ventricle pressure (dP/dtmax) in the 2K1C rats. Conclusions: These results indicate that the depressor effect can be controlled by changing the programs of the chip system. The closed-loop chip system effectively decreased arterial pressure and sympathetic outflow, increased baroreflex gain, and normalized the enhanced cardiac contractility in renovascular hypertensive rats.

Original languageEnglish (US)
Pages (from-to)BR153-BR158
JournalMedical Science Monitor
Volume14
Issue number8
StatePublished - Aug 1 2008

Fingerprint

Antihypertensive Agents
Arterial Pressure
Baroreflex
Heart Ventricles
Kidney
Pressure
Surgical Instruments
Running
Rabbits

Keywords

  • Baroreflex
  • Blood pressure
  • Chip
  • Hypertension
  • Sympathetic activity

ASJC Scopus subject areas

  • Medicine(all)

Cite this

Zhou, L. M., Zhu, G. Q., Wang, H. J., Zhao, C. K., Xu, Y., & Gao, X. Y. (2008). Anti-hypertensive effects of a closed-loop chip system in renovascular hypertensive rats. Medical Science Monitor, 14(8), BR153-BR158.

Anti-hypertensive effects of a closed-loop chip system in renovascular hypertensive rats. / Zhou, Li Min; Zhu, Guo Qing; Wang, Han Jun; Zhao, Cong Kan; Xu, Yao; Gao, Xing Ya.

In: Medical Science Monitor, Vol. 14, No. 8, 01.08.2008, p. BR153-BR158.

Research output: Contribution to journalArticle

Zhou, LM, Zhu, GQ, Wang, HJ, Zhao, CK, Xu, Y & Gao, XY 2008, 'Anti-hypertensive effects of a closed-loop chip system in renovascular hypertensive rats', Medical Science Monitor, vol. 14, no. 8, pp. BR153-BR158.
Zhou, Li Min ; Zhu, Guo Qing ; Wang, Han Jun ; Zhao, Cong Kan ; Xu, Yao ; Gao, Xing Ya. / Anti-hypertensive effects of a closed-loop chip system in renovascular hypertensive rats. In: Medical Science Monitor. 2008 ; Vol. 14, No. 8. pp. BR153-BR158.
@article{3e6101d3d9d44c2aab27ae4928af0287,
title = "Anti-hypertensive effects of a closed-loop chip system in renovascular hypertensive rats",
abstract = "Background: The authors' previous study showed a closed-loop chip system that was used to control arterial pressure in normal rabbits and rats. In the present study the anti-hypertensive effects of the chip system were investigated in anaesthetized two-kidney one-clip (2K1C) renovascular hypertensive rats and compared with sham-operated rats. Material/Methods: The chip system recorded, sampled, and processed the signals of arterial pressure and instantaneously controlled arterial pressure by stimulating the left aortic depressor nerve. The frequency of stimulation was determined according to the feedback signals of arterial pressure. Results: The chip system, running three different programs, successfully achieved a different degree of depressor effects. It effectively decreased not only mean arterial pressure (MAP), but also renal sympathetic nerve activity (RSNA) in both 2K1C rats and sham-operated rats. The chip system significantly increased the baroreflex gain in the 2K1C rats, but not in the sham-operated rats. It normalized the increased left ventricle developing pressure and maximal rise rate of the left ventricle pressure (dP/dtmax) in the 2K1C rats. Conclusions: These results indicate that the depressor effect can be controlled by changing the programs of the chip system. The closed-loop chip system effectively decreased arterial pressure and sympathetic outflow, increased baroreflex gain, and normalized the enhanced cardiac contractility in renovascular hypertensive rats.",
keywords = "Baroreflex, Blood pressure, Chip, Hypertension, Sympathetic activity",
author = "Zhou, {Li Min} and Zhu, {Guo Qing} and Wang, {Han Jun} and Zhao, {Cong Kan} and Yao Xu and Gao, {Xing Ya}",
year = "2008",
month = "8",
day = "1",
language = "English (US)",
volume = "14",
pages = "BR153--BR158",
journal = "Medical Science Monitor",
issn = "1234-1010",
publisher = "International Scientific Literature Inc.",
number = "8",

}

TY - JOUR

T1 - Anti-hypertensive effects of a closed-loop chip system in renovascular hypertensive rats

AU - Zhou, Li Min

AU - Zhu, Guo Qing

AU - Wang, Han Jun

AU - Zhao, Cong Kan

AU - Xu, Yao

AU - Gao, Xing Ya

PY - 2008/8/1

Y1 - 2008/8/1

N2 - Background: The authors' previous study showed a closed-loop chip system that was used to control arterial pressure in normal rabbits and rats. In the present study the anti-hypertensive effects of the chip system were investigated in anaesthetized two-kidney one-clip (2K1C) renovascular hypertensive rats and compared with sham-operated rats. Material/Methods: The chip system recorded, sampled, and processed the signals of arterial pressure and instantaneously controlled arterial pressure by stimulating the left aortic depressor nerve. The frequency of stimulation was determined according to the feedback signals of arterial pressure. Results: The chip system, running three different programs, successfully achieved a different degree of depressor effects. It effectively decreased not only mean arterial pressure (MAP), but also renal sympathetic nerve activity (RSNA) in both 2K1C rats and sham-operated rats. The chip system significantly increased the baroreflex gain in the 2K1C rats, but not in the sham-operated rats. It normalized the increased left ventricle developing pressure and maximal rise rate of the left ventricle pressure (dP/dtmax) in the 2K1C rats. Conclusions: These results indicate that the depressor effect can be controlled by changing the programs of the chip system. The closed-loop chip system effectively decreased arterial pressure and sympathetic outflow, increased baroreflex gain, and normalized the enhanced cardiac contractility in renovascular hypertensive rats.

AB - Background: The authors' previous study showed a closed-loop chip system that was used to control arterial pressure in normal rabbits and rats. In the present study the anti-hypertensive effects of the chip system were investigated in anaesthetized two-kidney one-clip (2K1C) renovascular hypertensive rats and compared with sham-operated rats. Material/Methods: The chip system recorded, sampled, and processed the signals of arterial pressure and instantaneously controlled arterial pressure by stimulating the left aortic depressor nerve. The frequency of stimulation was determined according to the feedback signals of arterial pressure. Results: The chip system, running three different programs, successfully achieved a different degree of depressor effects. It effectively decreased not only mean arterial pressure (MAP), but also renal sympathetic nerve activity (RSNA) in both 2K1C rats and sham-operated rats. The chip system significantly increased the baroreflex gain in the 2K1C rats, but not in the sham-operated rats. It normalized the increased left ventricle developing pressure and maximal rise rate of the left ventricle pressure (dP/dtmax) in the 2K1C rats. Conclusions: These results indicate that the depressor effect can be controlled by changing the programs of the chip system. The closed-loop chip system effectively decreased arterial pressure and sympathetic outflow, increased baroreflex gain, and normalized the enhanced cardiac contractility in renovascular hypertensive rats.

KW - Baroreflex

KW - Blood pressure

KW - Chip

KW - Hypertension

KW - Sympathetic activity

UR - http://www.scopus.com/inward/record.url?scp=50249110222&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=50249110222&partnerID=8YFLogxK

M3 - Article

C2 - 18667991

AN - SCOPUS:50249110222

VL - 14

SP - BR153-BR158

JO - Medical Science Monitor

JF - Medical Science Monitor

SN - 1234-1010

IS - 8

ER -