Analytical-performance improvement of aqueous solution by chemical replacement combined with surface-enhanced laser-induced breakdown spectroscopy

Xinyan Yang, Xiangyou Li, Zhifeng Cui, Zhongqi Hao, Yongfeng Lu, Jingchun Huang, Guanxin Yao, Xiaoli Wang

Research output: Contribution to journalArticle

2 Citations (Scopus)

Abstract

In this study, chemical replacement combined with surface-enhanced laser-induced breakdown spectroscopy (CR-SENLIBS) was introduced for detecting the trace chromium (Cr) element in an aqueous solution, which could use chemical replacement to change the sample from liquid to solid. In order to illustrate the analytical-performance of the CR-SENLIBS, the direct analysis of the liquid surface by LIBS (LSLIBS) was investigated for comparison. The results show that the spectral intensity of Cr I 357.86 nm, plasma lifetime, and spectral stability were improved. Moreover, the limit of detection of Cr I 357.86 nm was 0.018 μg/mL, which was lower than 1.814 μg/mL for LSLIBS. Furthermore, the accuracy and precision were improved more than 60% and 80%, respectively; for example, the root-mean-square error of cross-validation was improved from 1.09 to 0.75 μg/mL, and the average relative standard deviation of the predicted concentration of Cr was reduced from 22.89% to 4.53% by using CR-SENLIBS. These results suggest that CR-SENLIBS has good analytical-performance, which exhibits great potential in water quality monitoring.

Original languageEnglish (US)
Pages (from-to)7135-7139
Number of pages5
JournalApplied optics
Volume57
Issue number25
DOIs
StatePublished - Sep 1 2018

Fingerprint

Laser induced breakdown spectroscopy
laser-induced breakdown spectroscopy
chromium
aqueous solutions
Chromium
liquid surfaces
plasma lifetime
Liquids
water quality
root-mean-square errors
standard deviation
Mean square error
Water quality
Plasmas
liquids
Monitoring

ASJC Scopus subject areas

  • Atomic and Molecular Physics, and Optics
  • Electrical and Electronic Engineering

Cite this

Analytical-performance improvement of aqueous solution by chemical replacement combined with surface-enhanced laser-induced breakdown spectroscopy. / Yang, Xinyan; Li, Xiangyou; Cui, Zhifeng; Hao, Zhongqi; Lu, Yongfeng; Huang, Jingchun; Yao, Guanxin; Wang, Xiaoli.

In: Applied optics, Vol. 57, No. 25, 01.09.2018, p. 7135-7139.

Research output: Contribution to journalArticle

Yang, Xinyan ; Li, Xiangyou ; Cui, Zhifeng ; Hao, Zhongqi ; Lu, Yongfeng ; Huang, Jingchun ; Yao, Guanxin ; Wang, Xiaoli. / Analytical-performance improvement of aqueous solution by chemical replacement combined with surface-enhanced laser-induced breakdown spectroscopy. In: Applied optics. 2018 ; Vol. 57, No. 25. pp. 7135-7139.
@article{d83a264a3ccb4a0a918ed91c20ed22b7,
title = "Analytical-performance improvement of aqueous solution by chemical replacement combined with surface-enhanced laser-induced breakdown spectroscopy",
abstract = "In this study, chemical replacement combined with surface-enhanced laser-induced breakdown spectroscopy (CR-SENLIBS) was introduced for detecting the trace chromium (Cr) element in an aqueous solution, which could use chemical replacement to change the sample from liquid to solid. In order to illustrate the analytical-performance of the CR-SENLIBS, the direct analysis of the liquid surface by LIBS (LSLIBS) was investigated for comparison. The results show that the spectral intensity of Cr I 357.86 nm, plasma lifetime, and spectral stability were improved. Moreover, the limit of detection of Cr I 357.86 nm was 0.018 μg/mL, which was lower than 1.814 μg/mL for LSLIBS. Furthermore, the accuracy and precision were improved more than 60{\%} and 80{\%}, respectively; for example, the root-mean-square error of cross-validation was improved from 1.09 to 0.75 μg/mL, and the average relative standard deviation of the predicted concentration of Cr was reduced from 22.89{\%} to 4.53{\%} by using CR-SENLIBS. These results suggest that CR-SENLIBS has good analytical-performance, which exhibits great potential in water quality monitoring.",
author = "Xinyan Yang and Xiangyou Li and Zhifeng Cui and Zhongqi Hao and Yongfeng Lu and Jingchun Huang and Guanxin Yao and Xiaoli Wang",
year = "2018",
month = "9",
day = "1",
doi = "10.1364/AO.57.007135",
language = "English (US)",
volume = "57",
pages = "7135--7139",
journal = "Applied Optics",
issn = "1559-128X",
publisher = "The Optical Society",
number = "25",

}

TY - JOUR

T1 - Analytical-performance improvement of aqueous solution by chemical replacement combined with surface-enhanced laser-induced breakdown spectroscopy

AU - Yang, Xinyan

AU - Li, Xiangyou

AU - Cui, Zhifeng

AU - Hao, Zhongqi

AU - Lu, Yongfeng

AU - Huang, Jingchun

AU - Yao, Guanxin

AU - Wang, Xiaoli

PY - 2018/9/1

Y1 - 2018/9/1

N2 - In this study, chemical replacement combined with surface-enhanced laser-induced breakdown spectroscopy (CR-SENLIBS) was introduced for detecting the trace chromium (Cr) element in an aqueous solution, which could use chemical replacement to change the sample from liquid to solid. In order to illustrate the analytical-performance of the CR-SENLIBS, the direct analysis of the liquid surface by LIBS (LSLIBS) was investigated for comparison. The results show that the spectral intensity of Cr I 357.86 nm, plasma lifetime, and spectral stability were improved. Moreover, the limit of detection of Cr I 357.86 nm was 0.018 μg/mL, which was lower than 1.814 μg/mL for LSLIBS. Furthermore, the accuracy and precision were improved more than 60% and 80%, respectively; for example, the root-mean-square error of cross-validation was improved from 1.09 to 0.75 μg/mL, and the average relative standard deviation of the predicted concentration of Cr was reduced from 22.89% to 4.53% by using CR-SENLIBS. These results suggest that CR-SENLIBS has good analytical-performance, which exhibits great potential in water quality monitoring.

AB - In this study, chemical replacement combined with surface-enhanced laser-induced breakdown spectroscopy (CR-SENLIBS) was introduced for detecting the trace chromium (Cr) element in an aqueous solution, which could use chemical replacement to change the sample from liquid to solid. In order to illustrate the analytical-performance of the CR-SENLIBS, the direct analysis of the liquid surface by LIBS (LSLIBS) was investigated for comparison. The results show that the spectral intensity of Cr I 357.86 nm, plasma lifetime, and spectral stability were improved. Moreover, the limit of detection of Cr I 357.86 nm was 0.018 μg/mL, which was lower than 1.814 μg/mL for LSLIBS. Furthermore, the accuracy and precision were improved more than 60% and 80%, respectively; for example, the root-mean-square error of cross-validation was improved from 1.09 to 0.75 μg/mL, and the average relative standard deviation of the predicted concentration of Cr was reduced from 22.89% to 4.53% by using CR-SENLIBS. These results suggest that CR-SENLIBS has good analytical-performance, which exhibits great potential in water quality monitoring.

UR - http://www.scopus.com/inward/record.url?scp=85052664171&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85052664171&partnerID=8YFLogxK

U2 - 10.1364/AO.57.007135

DO - 10.1364/AO.57.007135

M3 - Article

C2 - 30182972

AN - SCOPUS:85052664171

VL - 57

SP - 7135

EP - 7139

JO - Applied Optics

JF - Applied Optics

SN - 1559-128X

IS - 25

ER -