Analysis of dicamba degradation by pseudomonas maltophilia using high-performance capillary electrophoresis

Ju Yang, Xiao Zhuo Wang, David S. Hage, Patricia L. Herman, Donald P. Weeks

Research output: Contribution to journalArticle

17 Citations (Scopus)

Abstract

A method based on high-performance capillary electrophoresis (HPCE) was developed for the simultaneous analysis of dicamba and its metabolites in media containing the bacterium Pseudomonas maltophilia. Dicamba, 3,6-dichlorosalicylic acid (DCSA), and related products were extracted from media samples using ether under acidic conditions and injected onto an HPCE system containing a pH 10.0 running buffer. Baseline resolution between these compounds was obtained at 30 kV with a total run time of 6 min on a 50-μm i.d. × 50-cm capillary. The linear range for dicamba and DCSA detected at 274 nm extended from 0 to 100 mg/liter and the dynamic range for both compounds extended to 2000 mg/liter. The within-run precision was ±5% or less throughout the entire concentration range studied. The limits of detection for dicamba and DCSA in the media samples were 6 and 2 mg/liter. This corresponded to detection limits of 0.3 and 0.1 ng, respectively, in the injected extracts. With this method it was possible to conduct preliminary studies examining the kinetics of dicamba metabolism in P. maltophilia.

Original languageEnglish (US)
Pages (from-to)37-42
Number of pages6
JournalAnalytical Biochemistry
Volume219
Issue number1
DOIs
StatePublished - May 15 1994

Fingerprint

Dicamba
Stenotrophomonas maltophilia
Capillary electrophoresis
Capillary Electrophoresis
Degradation
Limit of Detection
Enzyme kinetics
Acids
Metabolites
Metabolism
Ether
Bacteria
Buffers

ASJC Scopus subject areas

  • Biophysics
  • Biochemistry
  • Molecular Biology
  • Cell Biology

Cite this

Analysis of dicamba degradation by pseudomonas maltophilia using high-performance capillary electrophoresis. / Yang, Ju; Wang, Xiao Zhuo; Hage, David S.; Herman, Patricia L.; Weeks, Donald P.

In: Analytical Biochemistry, Vol. 219, No. 1, 15.05.1994, p. 37-42.

Research output: Contribution to journalArticle

Yang, Ju ; Wang, Xiao Zhuo ; Hage, David S. ; Herman, Patricia L. ; Weeks, Donald P. / Analysis of dicamba degradation by pseudomonas maltophilia using high-performance capillary electrophoresis. In: Analytical Biochemistry. 1994 ; Vol. 219, No. 1. pp. 37-42.
@article{511409e511c24e0f9f879e80f7187396,
title = "Analysis of dicamba degradation by pseudomonas maltophilia using high-performance capillary electrophoresis",
abstract = "A method based on high-performance capillary electrophoresis (HPCE) was developed for the simultaneous analysis of dicamba and its metabolites in media containing the bacterium Pseudomonas maltophilia. Dicamba, 3,6-dichlorosalicylic acid (DCSA), and related products were extracted from media samples using ether under acidic conditions and injected onto an HPCE system containing a pH 10.0 running buffer. Baseline resolution between these compounds was obtained at 30 kV with a total run time of 6 min on a 50-μm i.d. × 50-cm capillary. The linear range for dicamba and DCSA detected at 274 nm extended from 0 to 100 mg/liter and the dynamic range for both compounds extended to 2000 mg/liter. The within-run precision was ±5{\%} or less throughout the entire concentration range studied. The limits of detection for dicamba and DCSA in the media samples were 6 and 2 mg/liter. This corresponded to detection limits of 0.3 and 0.1 ng, respectively, in the injected extracts. With this method it was possible to conduct preliminary studies examining the kinetics of dicamba metabolism in P. maltophilia.",
author = "Ju Yang and Wang, {Xiao Zhuo} and Hage, {David S.} and Herman, {Patricia L.} and Weeks, {Donald P.}",
year = "1994",
month = "5",
day = "15",
doi = "10.1006/abio.1994.1228",
language = "English (US)",
volume = "219",
pages = "37--42",
journal = "Analytical Biochemistry",
issn = "0003-2697",
publisher = "Academic Press Inc.",
number = "1",

}

TY - JOUR

T1 - Analysis of dicamba degradation by pseudomonas maltophilia using high-performance capillary electrophoresis

AU - Yang, Ju

AU - Wang, Xiao Zhuo

AU - Hage, David S.

AU - Herman, Patricia L.

AU - Weeks, Donald P.

PY - 1994/5/15

Y1 - 1994/5/15

N2 - A method based on high-performance capillary electrophoresis (HPCE) was developed for the simultaneous analysis of dicamba and its metabolites in media containing the bacterium Pseudomonas maltophilia. Dicamba, 3,6-dichlorosalicylic acid (DCSA), and related products were extracted from media samples using ether under acidic conditions and injected onto an HPCE system containing a pH 10.0 running buffer. Baseline resolution between these compounds was obtained at 30 kV with a total run time of 6 min on a 50-μm i.d. × 50-cm capillary. The linear range for dicamba and DCSA detected at 274 nm extended from 0 to 100 mg/liter and the dynamic range for both compounds extended to 2000 mg/liter. The within-run precision was ±5% or less throughout the entire concentration range studied. The limits of detection for dicamba and DCSA in the media samples were 6 and 2 mg/liter. This corresponded to detection limits of 0.3 and 0.1 ng, respectively, in the injected extracts. With this method it was possible to conduct preliminary studies examining the kinetics of dicamba metabolism in P. maltophilia.

AB - A method based on high-performance capillary electrophoresis (HPCE) was developed for the simultaneous analysis of dicamba and its metabolites in media containing the bacterium Pseudomonas maltophilia. Dicamba, 3,6-dichlorosalicylic acid (DCSA), and related products were extracted from media samples using ether under acidic conditions and injected onto an HPCE system containing a pH 10.0 running buffer. Baseline resolution between these compounds was obtained at 30 kV with a total run time of 6 min on a 50-μm i.d. × 50-cm capillary. The linear range for dicamba and DCSA detected at 274 nm extended from 0 to 100 mg/liter and the dynamic range for both compounds extended to 2000 mg/liter. The within-run precision was ±5% or less throughout the entire concentration range studied. The limits of detection for dicamba and DCSA in the media samples were 6 and 2 mg/liter. This corresponded to detection limits of 0.3 and 0.1 ng, respectively, in the injected extracts. With this method it was possible to conduct preliminary studies examining the kinetics of dicamba metabolism in P. maltophilia.

UR - http://www.scopus.com/inward/record.url?scp=0028228549&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0028228549&partnerID=8YFLogxK

U2 - 10.1006/abio.1994.1228

DO - 10.1006/abio.1994.1228

M3 - Article

C2 - 8059953

AN - SCOPUS:0028228549

VL - 219

SP - 37

EP - 42

JO - Analytical Biochemistry

JF - Analytical Biochemistry

SN - 0003-2697

IS - 1

ER -