An o-toluidine method for detection of carbohydrates in protein hydrolysates

Tulin Morcol, William H. Velander

Research output: Contribution to journalArticle

9 Citations (Scopus)

Abstract

The o-toluidine high-performance thin-layer chromatography (HPTLC) method for detection of reducing sugars has been demonstrated to be a facile method for composition analysis of protein hydrolysates with a maximum sensitivity range of 50-100 pmol. The solution phase reaction of o-toluidine with reducing sugars has been previously used for spectrophotometric detection of glucose at 480-630 nm. In contrast, the heterogeneous reaction of o-toluidine with reducing sugars resolved by thin-layer chromatography produces chromophoric derivatives which have a broad absorbance at 295 nm. Detection of these chromophoric derivatives is achieved by uv diffuse reflectance scanning densitometry. It is demonstrated that detection limits of less than 10 ng can be achieved by using HPTLC plates and is therefore equal or more sensitive for some sugars than recently reported high-pressure liquid chromatography methods using amperometric or fluorescence detection.

Original languageEnglish (US)
Pages (from-to)153-159
Number of pages7
JournalAnalytical Biochemistry
Volume195
Issue number1
DOIs
StatePublished - May 15 1991

Fingerprint

2-toluidine
Protein Hydrolysates
Thin Layer Chromatography
Sugars
Thin layer chromatography
Carbohydrates
Densitometry
High pressure liquid chromatography
Derivatives
Limit of Detection
Fluorescence
High Pressure Liquid Chromatography
Glucose
Scanning
Chemical analysis

ASJC Scopus subject areas

  • Biophysics
  • Biochemistry
  • Molecular Biology
  • Cell Biology

Cite this

An o-toluidine method for detection of carbohydrates in protein hydrolysates. / Morcol, Tulin; Velander, William H.

In: Analytical Biochemistry, Vol. 195, No. 1, 15.05.1991, p. 153-159.

Research output: Contribution to journalArticle

@article{8816929b43c34fe88f4db20c7cc31c9c,
title = "An o-toluidine method for detection of carbohydrates in protein hydrolysates",
abstract = "The o-toluidine high-performance thin-layer chromatography (HPTLC) method for detection of reducing sugars has been demonstrated to be a facile method for composition analysis of protein hydrolysates with a maximum sensitivity range of 50-100 pmol. The solution phase reaction of o-toluidine with reducing sugars has been previously used for spectrophotometric detection of glucose at 480-630 nm. In contrast, the heterogeneous reaction of o-toluidine with reducing sugars resolved by thin-layer chromatography produces chromophoric derivatives which have a broad absorbance at 295 nm. Detection of these chromophoric derivatives is achieved by uv diffuse reflectance scanning densitometry. It is demonstrated that detection limits of less than 10 ng can be achieved by using HPTLC plates and is therefore equal or more sensitive for some sugars than recently reported high-pressure liquid chromatography methods using amperometric or fluorescence detection.",
author = "Tulin Morcol and Velander, {William H.}",
year = "1991",
month = "5",
day = "15",
doi = "10.1016/0003-2697(91)90311-G",
language = "English (US)",
volume = "195",
pages = "153--159",
journal = "Analytical Biochemistry",
issn = "0003-2697",
publisher = "Academic Press Inc.",
number = "1",

}

TY - JOUR

T1 - An o-toluidine method for detection of carbohydrates in protein hydrolysates

AU - Morcol, Tulin

AU - Velander, William H.

PY - 1991/5/15

Y1 - 1991/5/15

N2 - The o-toluidine high-performance thin-layer chromatography (HPTLC) method for detection of reducing sugars has been demonstrated to be a facile method for composition analysis of protein hydrolysates with a maximum sensitivity range of 50-100 pmol. The solution phase reaction of o-toluidine with reducing sugars has been previously used for spectrophotometric detection of glucose at 480-630 nm. In contrast, the heterogeneous reaction of o-toluidine with reducing sugars resolved by thin-layer chromatography produces chromophoric derivatives which have a broad absorbance at 295 nm. Detection of these chromophoric derivatives is achieved by uv diffuse reflectance scanning densitometry. It is demonstrated that detection limits of less than 10 ng can be achieved by using HPTLC plates and is therefore equal or more sensitive for some sugars than recently reported high-pressure liquid chromatography methods using amperometric or fluorescence detection.

AB - The o-toluidine high-performance thin-layer chromatography (HPTLC) method for detection of reducing sugars has been demonstrated to be a facile method for composition analysis of protein hydrolysates with a maximum sensitivity range of 50-100 pmol. The solution phase reaction of o-toluidine with reducing sugars has been previously used for spectrophotometric detection of glucose at 480-630 nm. In contrast, the heterogeneous reaction of o-toluidine with reducing sugars resolved by thin-layer chromatography produces chromophoric derivatives which have a broad absorbance at 295 nm. Detection of these chromophoric derivatives is achieved by uv diffuse reflectance scanning densitometry. It is demonstrated that detection limits of less than 10 ng can be achieved by using HPTLC plates and is therefore equal or more sensitive for some sugars than recently reported high-pressure liquid chromatography methods using amperometric or fluorescence detection.

UR - http://www.scopus.com/inward/record.url?scp=0025766295&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0025766295&partnerID=8YFLogxK

U2 - 10.1016/0003-2697(91)90311-G

DO - 10.1016/0003-2697(91)90311-G

M3 - Article

C2 - 1888012

AN - SCOPUS:0025766295

VL - 195

SP - 153

EP - 159

JO - Analytical Biochemistry

JF - Analytical Biochemistry

SN - 0003-2697

IS - 1

ER -