An indirect estimate of auditory-frequency selectivity from acoustic-reflex measurements

Patricia G Stelmachowicz, David J. Lilly

Research output: Contribution to journalArticle

2 Citations (Scopus)

Abstract

Changes in the magnitude of the acoustic reflex were used to estimate frequency resolution of the auditory system for five human subjects. Acoustic-reflex adaptation (decay) was produced by presenting a 2000-Hz sinusoid (adaptor) for 25 s. The spread of this adaptation to adjacent (test) frequencies was determined by evaluating the effect of the adaptor upon the magnitude of the acoustic reflex. The mean data from the experiment suggest that recovery from acoustic-reflex adaptation is more rapid for test frequencies below the adaptor frequency than for test frequencies above the adaptor. When these data are compared to tone-on-tone masking functions, qualitative similarities emerge between frequency selectivity observed psychophysically and those observed during measurement of acoustic-reflex activity.

Original languageEnglish (US)
Pages (from-to)1501-1508
Number of pages8
JournalJournal of the Acoustical Society of America
Volume65
Issue number6
DOIs
StatePublished - Jan 1 1979

Fingerprint

reflexes
selectivity
acoustics
estimates
sine waves
masking
Hearing
Acoustics
Reflex
recovery
decay

ASJC Scopus subject areas

  • Arts and Humanities (miscellaneous)
  • Acoustics and Ultrasonics

Cite this

An indirect estimate of auditory-frequency selectivity from acoustic-reflex measurements. / Stelmachowicz, Patricia G; Lilly, David J.

In: Journal of the Acoustical Society of America, Vol. 65, No. 6, 01.01.1979, p. 1501-1508.

Research output: Contribution to journalArticle

Stelmachowicz, Patricia G ; Lilly, David J. / An indirect estimate of auditory-frequency selectivity from acoustic-reflex measurements. In: Journal of the Acoustical Society of America. 1979 ; Vol. 65, No. 6. pp. 1501-1508.
@article{ea0f3cc5383d4bbe87f80ac839c88fc9,
title = "An indirect estimate of auditory-frequency selectivity from acoustic-reflex measurements",
abstract = "Changes in the magnitude of the acoustic reflex were used to estimate frequency resolution of the auditory system for five human subjects. Acoustic-reflex adaptation (decay) was produced by presenting a 2000-Hz sinusoid (adaptor) for 25 s. The spread of this adaptation to adjacent (test) frequencies was determined by evaluating the effect of the adaptor upon the magnitude of the acoustic reflex. The mean data from the experiment suggest that recovery from acoustic-reflex adaptation is more rapid for test frequencies below the adaptor frequency than for test frequencies above the adaptor. When these data are compared to tone-on-tone masking functions, qualitative similarities emerge between frequency selectivity observed psychophysically and those observed during measurement of acoustic-reflex activity.",
author = "Stelmachowicz, {Patricia G} and Lilly, {David J.}",
year = "1979",
month = "1",
day = "1",
doi = "10.1121/1.382914",
language = "English (US)",
volume = "65",
pages = "1501--1508",
journal = "Journal of the Acoustical Society of America",
issn = "0001-4966",
publisher = "Acoustical Society of America",
number = "6",

}

TY - JOUR

T1 - An indirect estimate of auditory-frequency selectivity from acoustic-reflex measurements

AU - Stelmachowicz, Patricia G

AU - Lilly, David J.

PY - 1979/1/1

Y1 - 1979/1/1

N2 - Changes in the magnitude of the acoustic reflex were used to estimate frequency resolution of the auditory system for five human subjects. Acoustic-reflex adaptation (decay) was produced by presenting a 2000-Hz sinusoid (adaptor) for 25 s. The spread of this adaptation to adjacent (test) frequencies was determined by evaluating the effect of the adaptor upon the magnitude of the acoustic reflex. The mean data from the experiment suggest that recovery from acoustic-reflex adaptation is more rapid for test frequencies below the adaptor frequency than for test frequencies above the adaptor. When these data are compared to tone-on-tone masking functions, qualitative similarities emerge between frequency selectivity observed psychophysically and those observed during measurement of acoustic-reflex activity.

AB - Changes in the magnitude of the acoustic reflex were used to estimate frequency resolution of the auditory system for five human subjects. Acoustic-reflex adaptation (decay) was produced by presenting a 2000-Hz sinusoid (adaptor) for 25 s. The spread of this adaptation to adjacent (test) frequencies was determined by evaluating the effect of the adaptor upon the magnitude of the acoustic reflex. The mean data from the experiment suggest that recovery from acoustic-reflex adaptation is more rapid for test frequencies below the adaptor frequency than for test frequencies above the adaptor. When these data are compared to tone-on-tone masking functions, qualitative similarities emerge between frequency selectivity observed psychophysically and those observed during measurement of acoustic-reflex activity.

UR - http://www.scopus.com/inward/record.url?scp=0018480108&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0018480108&partnerID=8YFLogxK

U2 - 10.1121/1.382914

DO - 10.1121/1.382914

M3 - Article

VL - 65

SP - 1501

EP - 1508

JO - Journal of the Acoustical Society of America

JF - Journal of the Acoustical Society of America

SN - 0001-4966

IS - 6