An examination of innervation zone movement with increases in isometric torque production

Jason M. DeFreitas, Pablo B. Costa, Eric D. Ryan, Trent J. Herda, Joel T Cramer, Travis W. Beck

Research output: Contribution to journalArticle

18 Citations (Scopus)

Abstract

Objective: To determine, with more precision than in previous investigations, if the innervation zone (IZ) for the biceps brachii can move with increases in isometric torque, and if so, whether or not that movement is influenced by differences in joint angle. Methods: Twenty-three participants (mean age = 21.7 years) performed isometric contractions of the forearm flexors at 20, 40, 60, 80, and 100% of their maximal voluntary contraction (MVC) at three separate elbow joint angles (90, 120, and 150°). During each contraction, 16 channels of bipolar surface electromyographic (EMG) signals were recorded from the biceps brachii using a linear electrode array. For each joint angle, movement of the IZ with increases in torque was identified by a change in the EMG channel that was over the IZ. Results: For each joint angle, the IZ shifted proximally (2.3 channels) with increases in torque from 20 to 100% MVC. With an interelectrode distance of 2.5 mm, this 2.3-channel shift reflects a 4.5-7.0 mm movement of the IZ. Conclusion: The IZ shifts proximally 4.5-7.0 mm with increases in isometric torque, independent of joint angle. Significance: These findings suggested that if isometric contractions are performed at different torque levels, the electrodes should be placed at least 7 mm from the IZ.

Original languageEnglish (US)
Pages (from-to)2795-2799
Number of pages5
JournalClinical Neurophysiology
Volume119
Issue number12
DOIs
StatePublished - Dec 1 2008

Fingerprint

Torque
Joints
Isometric Contraction
Electrodes
Elbow Joint
Forearm

Keywords

  • Biceps brachii
  • Electromyography
  • Innervation zone
  • Isometric

ASJC Scopus subject areas

  • Clinical Neurology
  • Neurology
  • Physiology (medical)
  • Sensory Systems

Cite this

An examination of innervation zone movement with increases in isometric torque production. / DeFreitas, Jason M.; Costa, Pablo B.; Ryan, Eric D.; Herda, Trent J.; Cramer, Joel T; Beck, Travis W.

In: Clinical Neurophysiology, Vol. 119, No. 12, 01.12.2008, p. 2795-2799.

Research output: Contribution to journalArticle

DeFreitas, Jason M. ; Costa, Pablo B. ; Ryan, Eric D. ; Herda, Trent J. ; Cramer, Joel T ; Beck, Travis W. / An examination of innervation zone movement with increases in isometric torque production. In: Clinical Neurophysiology. 2008 ; Vol. 119, No. 12. pp. 2795-2799.
@article{a09b3bdd642c4414848071aee1d8c843,
title = "An examination of innervation zone movement with increases in isometric torque production",
abstract = "Objective: To determine, with more precision than in previous investigations, if the innervation zone (IZ) for the biceps brachii can move with increases in isometric torque, and if so, whether or not that movement is influenced by differences in joint angle. Methods: Twenty-three participants (mean age = 21.7 years) performed isometric contractions of the forearm flexors at 20, 40, 60, 80, and 100{\%} of their maximal voluntary contraction (MVC) at three separate elbow joint angles (90, 120, and 150°). During each contraction, 16 channels of bipolar surface electromyographic (EMG) signals were recorded from the biceps brachii using a linear electrode array. For each joint angle, movement of the IZ with increases in torque was identified by a change in the EMG channel that was over the IZ. Results: For each joint angle, the IZ shifted proximally (2.3 channels) with increases in torque from 20 to 100{\%} MVC. With an interelectrode distance of 2.5 mm, this 2.3-channel shift reflects a 4.5-7.0 mm movement of the IZ. Conclusion: The IZ shifts proximally 4.5-7.0 mm with increases in isometric torque, independent of joint angle. Significance: These findings suggested that if isometric contractions are performed at different torque levels, the electrodes should be placed at least 7 mm from the IZ.",
keywords = "Biceps brachii, Electromyography, Innervation zone, Isometric",
author = "DeFreitas, {Jason M.} and Costa, {Pablo B.} and Ryan, {Eric D.} and Herda, {Trent J.} and Cramer, {Joel T} and Beck, {Travis W.}",
year = "2008",
month = "12",
day = "1",
doi = "10.1016/j.clinph.2008.09.021",
language = "English (US)",
volume = "119",
pages = "2795--2799",
journal = "Clinical Neurophysiology",
issn = "1388-2457",
publisher = "Elsevier Ireland Ltd",
number = "12",

}

TY - JOUR

T1 - An examination of innervation zone movement with increases in isometric torque production

AU - DeFreitas, Jason M.

AU - Costa, Pablo B.

AU - Ryan, Eric D.

AU - Herda, Trent J.

AU - Cramer, Joel T

AU - Beck, Travis W.

PY - 2008/12/1

Y1 - 2008/12/1

N2 - Objective: To determine, with more precision than in previous investigations, if the innervation zone (IZ) for the biceps brachii can move with increases in isometric torque, and if so, whether or not that movement is influenced by differences in joint angle. Methods: Twenty-three participants (mean age = 21.7 years) performed isometric contractions of the forearm flexors at 20, 40, 60, 80, and 100% of their maximal voluntary contraction (MVC) at three separate elbow joint angles (90, 120, and 150°). During each contraction, 16 channels of bipolar surface electromyographic (EMG) signals were recorded from the biceps brachii using a linear electrode array. For each joint angle, movement of the IZ with increases in torque was identified by a change in the EMG channel that was over the IZ. Results: For each joint angle, the IZ shifted proximally (2.3 channels) with increases in torque from 20 to 100% MVC. With an interelectrode distance of 2.5 mm, this 2.3-channel shift reflects a 4.5-7.0 mm movement of the IZ. Conclusion: The IZ shifts proximally 4.5-7.0 mm with increases in isometric torque, independent of joint angle. Significance: These findings suggested that if isometric contractions are performed at different torque levels, the electrodes should be placed at least 7 mm from the IZ.

AB - Objective: To determine, with more precision than in previous investigations, if the innervation zone (IZ) for the biceps brachii can move with increases in isometric torque, and if so, whether or not that movement is influenced by differences in joint angle. Methods: Twenty-three participants (mean age = 21.7 years) performed isometric contractions of the forearm flexors at 20, 40, 60, 80, and 100% of their maximal voluntary contraction (MVC) at three separate elbow joint angles (90, 120, and 150°). During each contraction, 16 channels of bipolar surface electromyographic (EMG) signals were recorded from the biceps brachii using a linear electrode array. For each joint angle, movement of the IZ with increases in torque was identified by a change in the EMG channel that was over the IZ. Results: For each joint angle, the IZ shifted proximally (2.3 channels) with increases in torque from 20 to 100% MVC. With an interelectrode distance of 2.5 mm, this 2.3-channel shift reflects a 4.5-7.0 mm movement of the IZ. Conclusion: The IZ shifts proximally 4.5-7.0 mm with increases in isometric torque, independent of joint angle. Significance: These findings suggested that if isometric contractions are performed at different torque levels, the electrodes should be placed at least 7 mm from the IZ.

KW - Biceps brachii

KW - Electromyography

KW - Innervation zone

KW - Isometric

UR - http://www.scopus.com/inward/record.url?scp=56349161082&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=56349161082&partnerID=8YFLogxK

U2 - 10.1016/j.clinph.2008.09.021

DO - 10.1016/j.clinph.2008.09.021

M3 - Article

VL - 119

SP - 2795

EP - 2799

JO - Clinical Neurophysiology

JF - Clinical Neurophysiology

SN - 1388-2457

IS - 12

ER -