Allergic reaction following insertion of a Pd-Cu-Au fixed partial denture

A clinical report

Paul A Hansen, Lesley A. West

Research output: Contribution to journalArticle

26 Citations (Scopus)

Abstract

A severe allergic reaction to a porcelain-fused-to-metal fixed partial denture containing 79% palladium, 2% gold, and 19% copper, resulting in a variety of symptoms and hospitalization of the patient, is reported. The reaction occurred 4 hours after cementation of the fixed partial denture. Suggestions for use of nongold metal alloys are discussed.

Original languageEnglish (US)
Pages (from-to)144-148
Number of pages5
JournalJournal of Prosthodontics
Volume6
Issue number2
DOIs
StatePublished - Jan 1 1997

Fingerprint

Fixed Partial Denture
Hypersensitivity
Metals
Cementation
Dental Porcelain
Palladium
Gold
Copper
Hospitalization

Keywords

  • Allergic reactions
  • Contact mucositis
  • Dental alloys
  • Fixed partial dentures

ASJC Scopus subject areas

  • Dentistry(all)

Cite this

Allergic reaction following insertion of a Pd-Cu-Au fixed partial denture : A clinical report. / Hansen, Paul A; West, Lesley A.

In: Journal of Prosthodontics, Vol. 6, No. 2, 01.01.1997, p. 144-148.

Research output: Contribution to journalArticle

@article{3bf398bfda1047fbbcadb46da59bb611,
title = "Allergic reaction following insertion of a Pd-Cu-Au fixed partial denture: A clinical report",
abstract = "A severe allergic reaction to a porcelain-fused-to-metal fixed partial denture containing 79{\%} palladium, 2{\%} gold, and 19{\%} copper, resulting in a variety of symptoms and hospitalization of the patient, is reported. The reaction occurred 4 hours after cementation of the fixed partial denture. Suggestions for use of nongold metal alloys are discussed.",
keywords = "Allergic reactions, Contact mucositis, Dental alloys, Fixed partial dentures",
author = "Hansen, {Paul A} and West, {Lesley A.}",
year = "1997",
month = "1",
day = "1",
doi = "10.1111/j.1532-849X.1997.tb00080.x",
language = "English (US)",
volume = "6",
pages = "144--148",
journal = "Journal of Prosthodontics",
issn = "1059-941X",
publisher = "Wiley-Blackwell",
number = "2",

}

TY - JOUR

T1 - Allergic reaction following insertion of a Pd-Cu-Au fixed partial denture

T2 - A clinical report

AU - Hansen, Paul A

AU - West, Lesley A.

PY - 1997/1/1

Y1 - 1997/1/1

N2 - A severe allergic reaction to a porcelain-fused-to-metal fixed partial denture containing 79% palladium, 2% gold, and 19% copper, resulting in a variety of symptoms and hospitalization of the patient, is reported. The reaction occurred 4 hours after cementation of the fixed partial denture. Suggestions for use of nongold metal alloys are discussed.

AB - A severe allergic reaction to a porcelain-fused-to-metal fixed partial denture containing 79% palladium, 2% gold, and 19% copper, resulting in a variety of symptoms and hospitalization of the patient, is reported. The reaction occurred 4 hours after cementation of the fixed partial denture. Suggestions for use of nongold metal alloys are discussed.

KW - Allergic reactions

KW - Contact mucositis

KW - Dental alloys

KW - Fixed partial dentures

UR - http://www.scopus.com/inward/record.url?scp=0031151737&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0031151737&partnerID=8YFLogxK

U2 - 10.1111/j.1532-849X.1997.tb00080.x

DO - 10.1111/j.1532-849X.1997.tb00080.x

M3 - Article

VL - 6

SP - 144

EP - 148

JO - Journal of Prosthodontics

JF - Journal of Prosthodontics

SN - 1059-941X

IS - 2

ER -