Airflow patterns due to door motion and pressurization in hospital isolation rooms

Ehsan S. Mousavi, Kevin R. Grosskopf

Research output: Contribution to journalArticle

11 Citations (Scopus)

Abstract

Certain pathogens are transmitted through air by respiratory droplets that desiccate shortly after emission and form droplet nuclei (Nicas et al. 2005). Droplet nuclei are sufficiently small (<5.0 μm) to remain suspended in air indefinitely and, thus, create a pathway between an infected and susceptible person (Sehulster et al. 2003). This process is called “airborne transmission.” Patients with an airborne infectious disease (e.g., measles, SARS, tuberculosis, varicella, etc.) are isolated from the healthcare environment in an airborne infection isolation room to protect other patients and healthcare workers. These rooms have special features to effectively contain and remove airborne pathogens. For example, a 2.5-Pa negative pressure relationship with adjoining spaces is required for an airborne infection isolation room to create directional airflow into the room and prevent the transmission of airborne pathogens from the airborne infection isolation room to adjacent healthcare spaces. Directional airflow, however, may be disrupted and even reversed by door-opening motion and the movement of people and equipment into and out of the airborne infection isolation room. This article highlights the results of both experimental and computation studies that explore air exchange and particle movement between an isolation room and anteroom relative to 3-, 5-, and 7-s door cycle speeds and between neutral and negative air pressure relationships.

Original languageEnglish (US)
Pages (from-to)379-384
Number of pages6
JournalScience and Technology for the Built Environment
Volume22
Issue number4
DOIs
StatePublished - May 18 2016

Fingerprint

Pressurization
Pathogens
Air

ASJC Scopus subject areas

  • Environmental Engineering
  • Building and Construction
  • Fluid Flow and Transfer Processes

Cite this

Airflow patterns due to door motion and pressurization in hospital isolation rooms. / Mousavi, Ehsan S.; Grosskopf, Kevin R.

In: Science and Technology for the Built Environment, Vol. 22, No. 4, 18.05.2016, p. 379-384.

Research output: Contribution to journalArticle

@article{ad48bf95cc014e6ab670b914c3d715f6,
title = "Airflow patterns due to door motion and pressurization in hospital isolation rooms",
abstract = "Certain pathogens are transmitted through air by respiratory droplets that desiccate shortly after emission and form droplet nuclei (Nicas et al. 2005). Droplet nuclei are sufficiently small (<5.0 μm) to remain suspended in air indefinitely and, thus, create a pathway between an infected and susceptible person (Sehulster et al. 2003). This process is called “airborne transmission.” Patients with an airborne infectious disease (e.g., measles, SARS, tuberculosis, varicella, etc.) are isolated from the healthcare environment in an airborne infection isolation room to protect other patients and healthcare workers. These rooms have special features to effectively contain and remove airborne pathogens. For example, a 2.5-Pa negative pressure relationship with adjoining spaces is required for an airborne infection isolation room to create directional airflow into the room and prevent the transmission of airborne pathogens from the airborne infection isolation room to adjacent healthcare spaces. Directional airflow, however, may be disrupted and even reversed by door-opening motion and the movement of people and equipment into and out of the airborne infection isolation room. This article highlights the results of both experimental and computation studies that explore air exchange and particle movement between an isolation room and anteroom relative to 3-, 5-, and 7-s door cycle speeds and between neutral and negative air pressure relationships.",
author = "Mousavi, {Ehsan S.} and Grosskopf, {Kevin R.}",
year = "2016",
month = "5",
day = "18",
doi = "10.1080/23744731.2016.1155959",
language = "English (US)",
volume = "22",
pages = "379--384",
journal = "Science and Technology for the Built Environment",
issn = "2374-4731",
publisher = "Taylor and Francis Ltd.",
number = "4",

}

TY - JOUR

T1 - Airflow patterns due to door motion and pressurization in hospital isolation rooms

AU - Mousavi, Ehsan S.

AU - Grosskopf, Kevin R.

PY - 2016/5/18

Y1 - 2016/5/18

N2 - Certain pathogens are transmitted through air by respiratory droplets that desiccate shortly after emission and form droplet nuclei (Nicas et al. 2005). Droplet nuclei are sufficiently small (<5.0 μm) to remain suspended in air indefinitely and, thus, create a pathway between an infected and susceptible person (Sehulster et al. 2003). This process is called “airborne transmission.” Patients with an airborne infectious disease (e.g., measles, SARS, tuberculosis, varicella, etc.) are isolated from the healthcare environment in an airborne infection isolation room to protect other patients and healthcare workers. These rooms have special features to effectively contain and remove airborne pathogens. For example, a 2.5-Pa negative pressure relationship with adjoining spaces is required for an airborne infection isolation room to create directional airflow into the room and prevent the transmission of airborne pathogens from the airborne infection isolation room to adjacent healthcare spaces. Directional airflow, however, may be disrupted and even reversed by door-opening motion and the movement of people and equipment into and out of the airborne infection isolation room. This article highlights the results of both experimental and computation studies that explore air exchange and particle movement between an isolation room and anteroom relative to 3-, 5-, and 7-s door cycle speeds and between neutral and negative air pressure relationships.

AB - Certain pathogens are transmitted through air by respiratory droplets that desiccate shortly after emission and form droplet nuclei (Nicas et al. 2005). Droplet nuclei are sufficiently small (<5.0 μm) to remain suspended in air indefinitely and, thus, create a pathway between an infected and susceptible person (Sehulster et al. 2003). This process is called “airborne transmission.” Patients with an airborne infectious disease (e.g., measles, SARS, tuberculosis, varicella, etc.) are isolated from the healthcare environment in an airborne infection isolation room to protect other patients and healthcare workers. These rooms have special features to effectively contain and remove airborne pathogens. For example, a 2.5-Pa negative pressure relationship with adjoining spaces is required for an airborne infection isolation room to create directional airflow into the room and prevent the transmission of airborne pathogens from the airborne infection isolation room to adjacent healthcare spaces. Directional airflow, however, may be disrupted and even reversed by door-opening motion and the movement of people and equipment into and out of the airborne infection isolation room. This article highlights the results of both experimental and computation studies that explore air exchange and particle movement between an isolation room and anteroom relative to 3-, 5-, and 7-s door cycle speeds and between neutral and negative air pressure relationships.

UR - http://www.scopus.com/inward/record.url?scp=84961392612&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84961392612&partnerID=8YFLogxK

U2 - 10.1080/23744731.2016.1155959

DO - 10.1080/23744731.2016.1155959

M3 - Article

AN - SCOPUS:84961392612

VL - 22

SP - 379

EP - 384

JO - Science and Technology for the Built Environment

JF - Science and Technology for the Built Environment

SN - 2374-4731

IS - 4

ER -