Affinity monoliths for ultrafast immunoextraction

Tao Jiang, Rangan Mallik, David S. Hage

Research output: Contribution to journalArticle

78 Citations (Scopus)

Abstract

Affinity monoliths based on a copolymer of glycidyl methacrylate and ethylene dimethacrylate were developed for ultrafast immunoextractions. Rabbit immunoglobulin G (IgG) and anti-FITC antibodies were used as model ligands for this work. The antibody content of the monoliths was optimized by varying both the polymerization and immobilization conditions for preparing such supports. The temperature and porogen composition used during polymerization showed significant effects on monolith morphology and on the amount of antibodies that could be coupled to these materials. The effects of various immobilization procedures and coupling conditions were also evaluated, including the coupling temperature, pH, protein concentration, and use of high buffer concentrations. The maximum ligand density obtained for rabbit IgG was approximately 60 mg/g. When a 4.5 mm i.d. × 0.95 mm monolith disk containing anti-FITC antibodies was used, 95% extraction of fluorescein was achieved in 100 ms. These properties make such monoliths attractive for work in the rapid isolation of analytes from biological samples. Similar columns can be developed for other targets by varying the types of antibodies or binding agents placed within the monoliths.

Original languageEnglish (US)
Pages (from-to)2362-2372
Number of pages11
JournalAnalytical chemistry
Volume77
Issue number8
DOIs
StatePublished - Apr 15 2005

Fingerprint

Antibodies
Fluorescein-5-isothiocyanate
Immunoglobulin G
Polymerization
Ligands
Fluorescein
Buffers
Copolymers
Temperature
Chemical analysis
Proteins
ethylene dimethacrylate
glycidyl methacrylate

ASJC Scopus subject areas

  • Analytical Chemistry

Cite this

Affinity monoliths for ultrafast immunoextraction. / Jiang, Tao; Mallik, Rangan; Hage, David S.

In: Analytical chemistry, Vol. 77, No. 8, 15.04.2005, p. 2362-2372.

Research output: Contribution to journalArticle

Jiang, Tao ; Mallik, Rangan ; Hage, David S. / Affinity monoliths for ultrafast immunoextraction. In: Analytical chemistry. 2005 ; Vol. 77, No. 8. pp. 2362-2372.
@article{349e91e2b08e4a1da453bd7d334e83a1,
title = "Affinity monoliths for ultrafast immunoextraction",
abstract = "Affinity monoliths based on a copolymer of glycidyl methacrylate and ethylene dimethacrylate were developed for ultrafast immunoextractions. Rabbit immunoglobulin G (IgG) and anti-FITC antibodies were used as model ligands for this work. The antibody content of the monoliths was optimized by varying both the polymerization and immobilization conditions for preparing such supports. The temperature and porogen composition used during polymerization showed significant effects on monolith morphology and on the amount of antibodies that could be coupled to these materials. The effects of various immobilization procedures and coupling conditions were also evaluated, including the coupling temperature, pH, protein concentration, and use of high buffer concentrations. The maximum ligand density obtained for rabbit IgG was approximately 60 mg/g. When a 4.5 mm i.d. × 0.95 mm monolith disk containing anti-FITC antibodies was used, 95{\%} extraction of fluorescein was achieved in 100 ms. These properties make such monoliths attractive for work in the rapid isolation of analytes from biological samples. Similar columns can be developed for other targets by varying the types of antibodies or binding agents placed within the monoliths.",
author = "Tao Jiang and Rangan Mallik and Hage, {David S.}",
year = "2005",
month = "4",
day = "15",
doi = "10.1021/ac0483668",
language = "English (US)",
volume = "77",
pages = "2362--2372",
journal = "Analytical Chemistry",
issn = "0003-2700",
publisher = "American Chemical Society",
number = "8",

}

TY - JOUR

T1 - Affinity monoliths for ultrafast immunoextraction

AU - Jiang, Tao

AU - Mallik, Rangan

AU - Hage, David S.

PY - 2005/4/15

Y1 - 2005/4/15

N2 - Affinity monoliths based on a copolymer of glycidyl methacrylate and ethylene dimethacrylate were developed for ultrafast immunoextractions. Rabbit immunoglobulin G (IgG) and anti-FITC antibodies were used as model ligands for this work. The antibody content of the monoliths was optimized by varying both the polymerization and immobilization conditions for preparing such supports. The temperature and porogen composition used during polymerization showed significant effects on monolith morphology and on the amount of antibodies that could be coupled to these materials. The effects of various immobilization procedures and coupling conditions were also evaluated, including the coupling temperature, pH, protein concentration, and use of high buffer concentrations. The maximum ligand density obtained for rabbit IgG was approximately 60 mg/g. When a 4.5 mm i.d. × 0.95 mm monolith disk containing anti-FITC antibodies was used, 95% extraction of fluorescein was achieved in 100 ms. These properties make such monoliths attractive for work in the rapid isolation of analytes from biological samples. Similar columns can be developed for other targets by varying the types of antibodies or binding agents placed within the monoliths.

AB - Affinity monoliths based on a copolymer of glycidyl methacrylate and ethylene dimethacrylate were developed for ultrafast immunoextractions. Rabbit immunoglobulin G (IgG) and anti-FITC antibodies were used as model ligands for this work. The antibody content of the monoliths was optimized by varying both the polymerization and immobilization conditions for preparing such supports. The temperature and porogen composition used during polymerization showed significant effects on monolith morphology and on the amount of antibodies that could be coupled to these materials. The effects of various immobilization procedures and coupling conditions were also evaluated, including the coupling temperature, pH, protein concentration, and use of high buffer concentrations. The maximum ligand density obtained for rabbit IgG was approximately 60 mg/g. When a 4.5 mm i.d. × 0.95 mm monolith disk containing anti-FITC antibodies was used, 95% extraction of fluorescein was achieved in 100 ms. These properties make such monoliths attractive for work in the rapid isolation of analytes from biological samples. Similar columns can be developed for other targets by varying the types of antibodies or binding agents placed within the monoliths.

UR - http://www.scopus.com/inward/record.url?scp=17644385258&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=17644385258&partnerID=8YFLogxK

U2 - 10.1021/ac0483668

DO - 10.1021/ac0483668

M3 - Article

C2 - 15828768

AN - SCOPUS:17644385258

VL - 77

SP - 2362

EP - 2372

JO - Analytical Chemistry

JF - Analytical Chemistry

SN - 0003-2700

IS - 8