A methodology for using SPECT to reduce intensity-modulated radiation therapy (IMRT) dose to functioning lung

Sarah M. McGuire, Sumin Zhou, Lawrence B. Marks, Mark Dewhirst, Fang Fang Yin, Shiva K. Das

Research output: Contribution to journalArticle

66 Citations (Scopus)

Abstract

Purpose: Single photon emission computed tomography (SPECT) provides a map of the spatial distribution of lung perfusion. Thus, SPECT guidance can be used to divert dose away from higher-functioning lung, potentially reducing lung toxicity. We present a methodology for achieving this aim and test it in intensity-modulated radiotherapy (IMRT) treatment-planning. Methods and Materials: IMRT treatment plans were generated with and without SPECT guidance and compared for 5 patients. Healthy lung was segmented into four regions on the basis of SPECT intensity in the SPECT plan. Dose was sequentially allowed to the target via regions of increasing SPECT intensity. This process results in reduction of dose to functional lung, reflected in the dose-function histogram (DFH). The plans were compared using DFHs and F20/F30 values (Fx is the functional lung receiving dose above x Gy). Results: In all cases, the SPECT-guided plan produced a more favorable DFH compared with the non-SPECT-guided plan. Additionally, the F20 and F30 values were reduced for all patients by an average of 13.6% ± 5.2% and 10.5% ± 5.8%, respectively. In all patients, DFHs of the two highest-functioning SPECT regions were reduced, whereas DFHs of the two lower-functioning regions were increased, illustrating the dose "give-take" between SPECT regions during redistribution. Conclusions: SPECT-guided IMRT shows potential for reducing the dose delivered to highly functional lung regions. This dose reduction could reduce the number of high-grade pneumonitis cases that develop after radiation treatment and improve patient quality of life.

Original languageEnglish (US)
Pages (from-to)1543-1552
Number of pages10
JournalInternational Journal of Radiation Oncology Biology Physics
Volume66
Issue number5
DOIs
StatePublished - Dec 1 2006

Fingerprint

Single-Photon Emission-Computed Tomography
lungs
radiation therapy
Radiotherapy
tomography
methodology
dosage
Lung
photons
histograms
Emission-Computed Tomography
Intensity-Modulated Radiotherapy
Photons
toxicity
Pneumonia
planning
Therapeutics
Perfusion
grade
spatial distribution

Keywords

  • IMRT
  • Lung
  • Optimization
  • Radiation therapy
  • SPECT

ASJC Scopus subject areas

  • Radiation
  • Oncology
  • Radiology Nuclear Medicine and imaging
  • Cancer Research

Cite this

A methodology for using SPECT to reduce intensity-modulated radiation therapy (IMRT) dose to functioning lung. / McGuire, Sarah M.; Zhou, Sumin; Marks, Lawrence B.; Dewhirst, Mark; Yin, Fang Fang; Das, Shiva K.

In: International Journal of Radiation Oncology Biology Physics, Vol. 66, No. 5, 01.12.2006, p. 1543-1552.

Research output: Contribution to journalArticle

McGuire, Sarah M. ; Zhou, Sumin ; Marks, Lawrence B. ; Dewhirst, Mark ; Yin, Fang Fang ; Das, Shiva K. / A methodology for using SPECT to reduce intensity-modulated radiation therapy (IMRT) dose to functioning lung. In: International Journal of Radiation Oncology Biology Physics. 2006 ; Vol. 66, No. 5. pp. 1543-1552.
@article{394a244c09c84c61955aa1170a3c85c2,
title = "A methodology for using SPECT to reduce intensity-modulated radiation therapy (IMRT) dose to functioning lung",
abstract = "Purpose: Single photon emission computed tomography (SPECT) provides a map of the spatial distribution of lung perfusion. Thus, SPECT guidance can be used to divert dose away from higher-functioning lung, potentially reducing lung toxicity. We present a methodology for achieving this aim and test it in intensity-modulated radiotherapy (IMRT) treatment-planning. Methods and Materials: IMRT treatment plans were generated with and without SPECT guidance and compared for 5 patients. Healthy lung was segmented into four regions on the basis of SPECT intensity in the SPECT plan. Dose was sequentially allowed to the target via regions of increasing SPECT intensity. This process results in reduction of dose to functional lung, reflected in the dose-function histogram (DFH). The plans were compared using DFHs and F20/F30 values (Fx is the functional lung receiving dose above x Gy). Results: In all cases, the SPECT-guided plan produced a more favorable DFH compared with the non-SPECT-guided plan. Additionally, the F20 and F30 values were reduced for all patients by an average of 13.6{\%} ± 5.2{\%} and 10.5{\%} ± 5.8{\%}, respectively. In all patients, DFHs of the two highest-functioning SPECT regions were reduced, whereas DFHs of the two lower-functioning regions were increased, illustrating the dose {"}give-take{"} between SPECT regions during redistribution. Conclusions: SPECT-guided IMRT shows potential for reducing the dose delivered to highly functional lung regions. This dose reduction could reduce the number of high-grade pneumonitis cases that develop after radiation treatment and improve patient quality of life.",
keywords = "IMRT, Lung, Optimization, Radiation therapy, SPECT",
author = "McGuire, {Sarah M.} and Sumin Zhou and Marks, {Lawrence B.} and Mark Dewhirst and Yin, {Fang Fang} and Das, {Shiva K.}",
year = "2006",
month = "12",
day = "1",
doi = "10.1016/j.ijrobp.2006.07.1377",
language = "English (US)",
volume = "66",
pages = "1543--1552",
journal = "International Journal of Radiation Oncology Biology Physics",
issn = "0360-3016",
publisher = "Elsevier Inc.",
number = "5",

}

TY - JOUR

T1 - A methodology for using SPECT to reduce intensity-modulated radiation therapy (IMRT) dose to functioning lung

AU - McGuire, Sarah M.

AU - Zhou, Sumin

AU - Marks, Lawrence B.

AU - Dewhirst, Mark

AU - Yin, Fang Fang

AU - Das, Shiva K.

PY - 2006/12/1

Y1 - 2006/12/1

N2 - Purpose: Single photon emission computed tomography (SPECT) provides a map of the spatial distribution of lung perfusion. Thus, SPECT guidance can be used to divert dose away from higher-functioning lung, potentially reducing lung toxicity. We present a methodology for achieving this aim and test it in intensity-modulated radiotherapy (IMRT) treatment-planning. Methods and Materials: IMRT treatment plans were generated with and without SPECT guidance and compared for 5 patients. Healthy lung was segmented into four regions on the basis of SPECT intensity in the SPECT plan. Dose was sequentially allowed to the target via regions of increasing SPECT intensity. This process results in reduction of dose to functional lung, reflected in the dose-function histogram (DFH). The plans were compared using DFHs and F20/F30 values (Fx is the functional lung receiving dose above x Gy). Results: In all cases, the SPECT-guided plan produced a more favorable DFH compared with the non-SPECT-guided plan. Additionally, the F20 and F30 values were reduced for all patients by an average of 13.6% ± 5.2% and 10.5% ± 5.8%, respectively. In all patients, DFHs of the two highest-functioning SPECT regions were reduced, whereas DFHs of the two lower-functioning regions were increased, illustrating the dose "give-take" between SPECT regions during redistribution. Conclusions: SPECT-guided IMRT shows potential for reducing the dose delivered to highly functional lung regions. This dose reduction could reduce the number of high-grade pneumonitis cases that develop after radiation treatment and improve patient quality of life.

AB - Purpose: Single photon emission computed tomography (SPECT) provides a map of the spatial distribution of lung perfusion. Thus, SPECT guidance can be used to divert dose away from higher-functioning lung, potentially reducing lung toxicity. We present a methodology for achieving this aim and test it in intensity-modulated radiotherapy (IMRT) treatment-planning. Methods and Materials: IMRT treatment plans were generated with and without SPECT guidance and compared for 5 patients. Healthy lung was segmented into four regions on the basis of SPECT intensity in the SPECT plan. Dose was sequentially allowed to the target via regions of increasing SPECT intensity. This process results in reduction of dose to functional lung, reflected in the dose-function histogram (DFH). The plans were compared using DFHs and F20/F30 values (Fx is the functional lung receiving dose above x Gy). Results: In all cases, the SPECT-guided plan produced a more favorable DFH compared with the non-SPECT-guided plan. Additionally, the F20 and F30 values were reduced for all patients by an average of 13.6% ± 5.2% and 10.5% ± 5.8%, respectively. In all patients, DFHs of the two highest-functioning SPECT regions were reduced, whereas DFHs of the two lower-functioning regions were increased, illustrating the dose "give-take" between SPECT regions during redistribution. Conclusions: SPECT-guided IMRT shows potential for reducing the dose delivered to highly functional lung regions. This dose reduction could reduce the number of high-grade pneumonitis cases that develop after radiation treatment and improve patient quality of life.

KW - IMRT

KW - Lung

KW - Optimization

KW - Radiation therapy

KW - SPECT

UR - http://www.scopus.com/inward/record.url?scp=33751178998&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=33751178998&partnerID=8YFLogxK

U2 - 10.1016/j.ijrobp.2006.07.1377

DO - 10.1016/j.ijrobp.2006.07.1377

M3 - Article

C2 - 17126212

AN - SCOPUS:33751178998

VL - 66

SP - 1543

EP - 1552

JO - International Journal of Radiation Oncology Biology Physics

JF - International Journal of Radiation Oncology Biology Physics

SN - 0360-3016

IS - 5

ER -