Hani Haider, PhD

Professor

  • 1627 Citations
  • 21 h-Index
19952019
If you made any changes in Pure, your changes will be visible here soon.

Research Output 1995 2019

2019
Osteoblasts
Genes
Bone
Ions
Cell death
2017
10 Citations (Scopus)

Effects of carbon addition on wear mechanisms of CoCrMo metal-on-metal hip joint bearings

Chen, Y., Li, Y., Koizumi, Y., Haider, H. & Chiba, A., Jul 1 2017, In : Materials Science and Engineering C. 76, p. 997-1004 8 p.

Research output: Contribution to journalArticle

Bearings (structural)
metal joints
Carbon
Metals
Wear of materials
1 Citation (Scopus)

Why Coating Technologies for Hip Replacement Systems, and the Importance of Testing Them In Vitro

Haider, H., Weisenburger, J. N., Namavar, F. & Garvin, K. L., Sep 2017, In : Operative Techniques in Orthopaedics. 27, 3, p. 152-160 9 p.

Research output: Contribution to journalArticle

Hip
Metals
Technology
Hip Replacement Arthroplasties
Ions
2016
27 Citations (Scopus)

Antibiotic-tolerant Staphylococcus aureus Biofilm Persists on Arthroplasty Materials

Urish, K. L., DeMuth, P. W., Kwan, B. W., Craft, D. W., Ma, D., Haider, H., Tuan, R. S., Wood, T. K. & Davis, C. M., Jul 1 2016, In : Clinical Orthopaedics and Related Research. 474, 7, p. 1649-1656 8 p.

Research output: Contribution to journalArticle

Biofilms
Arthroplasty
Staphylococcus aureus
Cefazolin
Anti-Bacterial Agents
3 Citations (Scopus)
Simulators
Wear of materials
Friction
Ultrahigh molecular weight polyethylenes
Metals
1 Citation (Scopus)

Tribological Assessment of UHMWPE in the Knee

Haider, H., Jan 1 2016, UHMWPE Biomaterials Handbook: Ultra High Molecular Weight Polyethylene in Total Joint Replacement and Medical Devices: Third Edition. Elsevier Inc., p. 599-634 36 p.

Research output: Chapter in Book/Report/Conference proceedingChapter

Knee prostheses
Ultrahigh molecular weight polyethylenes
Bearings (structural)
Prosthetics
Product design
4 Citations (Scopus)

Using a surrogate contact pair to evaluate polyethylene wear in prosthetic knee joints

Sanders, A. P., Lockard, C. A., Weisenburger, J. N., Haider, H. & Raeymaekers, B., Jan 1 2016, In : Journal of Biomedical Materials Research - Part B Applied Biomaterials. 104, 1, p. 133-140 8 p.

Research output: Contribution to journalArticle

Polyethylene
Ultrahigh molecular weight polyethylenes
Prosthetics
Polyethylenes
Wear of materials
4 Citations (Scopus)

Wear Assessment of UHMWPE with Pin-on-Disc Testing

Haider, H. & Baykal, D., Jan 1 2016, UHMWPE Biomaterials Handbook: Ultra High Molecular Weight Polyethylene in Total Joint Replacement and Medical Devices: Third Edition. Elsevier Inc., p. 553-578 26 p.

Research output: Chapter in Book/Report/Conference proceedingChapter

Ultrahigh molecular weight polyethylenes
Wear of materials
Testing
Bearings (structural)
Orthopedics
2015

Direct Navigation of Surgical Instrumentation

Andres Barrera, O. & Haider, H., Jan 1 2015, Computer-Assisted Musculoskeletal Surgery: Thinking and Executing in 3D. Springer International Publishing, p. 99-113 15 p.

Research output: Chapter in Book/Report/Conference proceedingChapter

Jigs
Arthroplasty
Navigation
Replacement Arthroplasties
Cadaveric experiments
2014
37 Citations (Scopus)

Advances in tribological testing of artificial joint biomaterials using multidirectional pin-on-disk testers

Baykal, D., Siskey, R. S., Haider, H., Saikko, V., Ahlroos, T. & Kurtz, S. M., Mar 1 2014, In : Journal of the Mechanical Behavior of Biomedical Materials. 31, p. 117-134 18 p.

Research output: Contribution to journalReview article

Ultrahigh molecular weight polyethylenes
Biocompatible Materials
Biomaterials
Wear of materials
Testing
28 Citations (Scopus)

Pulse lavage is inadequate at removal of biofilm from the surface of total knee arthroplasty materials

Urish, K. L., DeMuth, P. W., Craft, D. W., Haider, H. & Davis, C. M., Jun 2014, In : Journal of Arthroplasty. 29, 6, p. 1128-1132 5 p.

Research output: Contribution to journalArticle

Knee Replacement Arthroplasties
Therapeutic Irrigation
Biofilms
Debridement
Infection
2013
11 Citations (Scopus)

Titanium implant with nanostructured zirconia surface promotes maturation of peri-implant bone in osseointegration

Dusad, A., Chakkalakal, D. A., Namavar, F., Haider, H., Hanisch, B., Duryee, M. J., Diaz, A., Rensch, A., Zhang, Y., Hess, R., Thiele, G. M. & Fehringer, E. V., May 1 2013, In : Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine. 227, 5, p. 510-522 13 p.

Research output: Contribution to journalArticle

Osseointegration
Titanium
Zirconia
Bone
Bone and Bones
8 Citations (Scopus)

Total knee arthroplasty with a computer-navigated saw: A pilot study knee

Garvin, K. L., Barrera, A., Mahoney, C. R., Hartman, C. W. & Haider, H., Jan 2013, In : Clinical Orthopaedics and Related Research. 471, 1, p. 155-161 7 p.

Research output: Contribution to journalArticle

Knee Replacement Arthroplasties
Knee
Bone and Bones
Thigh
Computer-Assisted Surgery
2012
52 Citations (Scopus)

Does Vitamin E-Stabilized Ultrahigh-Molecular-Weight Polyethylene Address Concerns of Cross-Linked Polyethylene in Total Knee Arthroplasty?

Haider, H., Weisenburger, J. N., Kurtz, S. M., Rimnac, C. M., Freedman, J., Schroeder, D. W. & Garvin, K. L., Mar 1 2012, In : Journal of Arthroplasty. 27, 3, p. 461-469 9 p.

Research output: Contribution to journalArticle

Knee Replacement Arthroplasties
Polyethylene
Vitamin E
Fatigue
ultra-high molecular weight polyethylene
3 Citations (Scopus)

Standard testing methods for mobile bearing knees

Walker, P. S. & Haider, H., Feb 2012, In : Journal of ASTM International. 9, 2

Research output: Contribution to journalArticle

Bearings (structural)
Knee Replacement Arthroplasties
Knee
Testing
Biomechanical Phenomena

Standard testing methods for mobile bearing knees

Walker, P. S. & Haider, H., Jan 1 2012, Mobile Bearing Total Knee Replacement Devices. ASTM International, p. 1-12 12 p. (ASTM Special Technical Publication; vol. 1531 STP).

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Bearings (structural)
Testing
Wear of materials
Arthroplasty
Failure modes

Wear of mobile bearing knees: Is it necessarily less?

Haider, H. & Kaddick, C., Jan 1 2012, Mobile Bearing Total Knee Replacement Devices. ASTM International, p. 218-231 14 p. (ASTM Special Technical Publication; vol. 1531 STP).

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Bearings (structural)
Knee prostheses
Wear of materials
Force control
Testing
5 Citations (Scopus)

Wear of mobile bearing knees: Is it necessarily less?

Haider, H. & Kaddick, C., Feb 2012, In : Journal of ASTM International. 9, 2

Research output: Contribution to journalArticle

Bearings (structural)
Knee Replacement Arthroplasties
Knee
Knee prostheses
Wear of materials
2011
13 Citations (Scopus)

Nanosized rutile (TiO2) thin film upon ion irradiation and thermal annealing

Zhang, J., Lian, J., Namavar, F., Wang, J., Haider, H., Garvin, K. L. & Ewing, R. C., Nov 24 2011, In : Journal of Physical Chemistry C. 115, 46, p. 22755-22760 6 p.

Research output: Contribution to journalArticle

Ion bombardment
ion irradiation
rutile
Irradiation
Annealing
2010
15 Citations (Scopus)

In vitro response of the natural cadaver knee to the loading profiles specified in a standard for knee implant wear testing

Sutton, L. G., Werner, F. W., Haider, H., Hamblin, T. & Clabeaux, J. J., Aug 1 2010, In : Journal of Biomechanics. 43, 11, p. 2203-2207 5 p.

Research output: Contribution to journalArticle

Cadaver
Knee
Wear of materials
Testing
Standardization
2009
40 Citations (Scopus)

Ion beam-induced amorphous-to-tetragonal phase transformation and grain growth of nanocrystalline zirconia

Lian, J., Zhang, J., Namavar, F., Zhang, Y., Lu, F., Haider, H., Garvin, K. L., Weber, W. J. & Ewing, R. C., Jun 29 2009, In : Nanotechnology. 20, 24, 245303.

Research output: Contribution to journalArticle

Grain growth
Zirconia
Ion beams
Phase transitions
Irradiation
21 Citations (Scopus)

Tribological Assessment of UHMWPE in the Knee

Haider, H., Dec 1 2009, UHMWPE Biomaterials Handbook. Elsevier Inc., p. 381-408 28 p.

Research output: Chapter in Book/Report/Conference proceedingChapter

Knee prostheses
Ultrahigh molecular weight polyethylenes
Testing
Screening
Bearings (structural)
2008
16 Citations (Scopus)

Local structures surrounding Zr in nanostructurally stabilized cubic zirconia: Structural origin of phase stability

Soo, Y. L., Chen, P. J., Huang, S. H., Shiu, T. J., Tsai, T. Y., Chow, Y. H., Lin, Y. C., Weng, S. C., Chang, S. L., Wang, G., Cheung, C. L. B., Sabirianov, R. F., Mei, W. N., Namavar, F., Haider, H., Garvin, K. L., Lee, J. F., Lee, H. Y. & Chu, P. P., Dec 1 2008, In : Journal of Applied Physics. 104, 11, 113535.

Research output: Contribution to journalArticle

zirconium oxides
x ray absorption
sublattices
oxygen
fine structure
64 Citations (Scopus)

Lotus effect in engineered zirconia

Namavar, F., Cheung, C. L., Sabirianov, R. F., Mei, W. N., Zeng, X. C., Wang, G., Haider, H. & Garvin, K. L., Apr 1 2008, In : Nano Letters. 8, 4, p. 988-996 9 p.

Research output: Contribution to journalArticle

zirconium oxides
Zirconia
Bearings (structural)
tribology
Tribology
47 Citations (Scopus)

Probabilistic computational modeling of total knee replacement wear

Pal, S., Haider, H., Laz, P. J., Knight, L. A. & Rullkoetter, P. J., Mar 15 2008, In : Wear. 264, 7-8, p. 701-707 7 p.

Research output: Contribution to journalArticle

Knee prostheses
Wear of materials
retrieval
predictions
alignment
48 Citations (Scopus)

Rotating platform versus fixed-bearing total knees: An in vitro study of wear

Haider, H. & Garvin, K. L., Nov 2008, In : Clinical Orthopaedics and Related Research. 466, 11, p. 2677-2685 9 p.

Research output: Contribution to journalArticle

Knee
Knee Replacement Arthroplasties
Toes
Polyethylene
Biomechanical Phenomena
8 Citations (Scopus)

Structural study of titanium oxide films synthesized by ion beam-assisted deposition

Wang, G., Brewer, J. R., Namavar, F., Sabirianov, R. F., Haider, H., Garvin, K. L. & Cheung, C. L. B., Mar 1 2008, In : Scanning. 30, 2, p. 59-64 6 p.

Research output: Contribution to journalArticle

Ion beam assisted deposition
Titanium oxides
titanium oxides
Oxide films
oxide films
11 Citations (Scopus)
Knee prostheses
Bone
Arthroplasty
Quality management
Orthopedics
2007
36 Citations (Scopus)

Anterior plate supplementation increases ankle arthrodesis construct rigidity

Tarkin, I. S., Mormino, M. A., Clare, M. P., Haider, H., Walling, A. K. & Sanders, R. W., Feb 1 2007, In : Foot and Ankle International. 28, 2, p. 219-223 5 p.

Research output: Contribution to journalArticle

Arthrodesis
Ankle
Cadaver
Arthritis
Therapeutics
107 Citations (Scopus)

Comparison of long-term numerical and experimental total knee replacement wear during simulated gait loading

Knight, L. A., Pal, S., Coleman, J. C., Bronson, F., Haider, H., Levine, D. L., Taylor, M. & Rullkoetter, P. J., Apr 23 2007, In : Journal of Biomechanics. 40, 7, p. 1550-1558 9 p.

Research output: Contribution to journalArticle

Knee prostheses
Knee Replacement Arthroplasties
Gait
Biomechanical Phenomena
Wear of materials
1 Citation (Scopus)

Effects of patient and surgical alignment variables on kinematics in TKR simulation under force-control

Haider, H., Walker, P., Desjardins, J. & Blunn, G., Jan 1 2007, Wear of Articulating Surfaces: Understanding Joint Simulation. ASTM International, p. 3-16 14 p. (ASTM Special Technical Publication; vol. 1472 STP).

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Knee prostheses
Ligaments
Force control
Kinematics
Bearings (structural)
20 Citations (Scopus)
Knee Replacement Arthroplasties
Bone and Bones
Computer-Assisted Surgery
Thigh
Arthroplasty
56 Citations (Scopus)

Thermal stability of nanostructurally stabilized zirconium oxide

Namavar, F., Wang, G., Cheung, C. L. B., Sabirianov, R. F., Zeng, X. C., Mei, W. N., Bai, J., Brewer, J. R., Haider, H. & Garvin, K. L., Oct 17 2007, In : Nanotechnology. 18, 41, 415702.

Research output: Contribution to journalArticle

Zirconia
Thermodynamic stability
Ion beam assisted deposition
Oxide films
X rays
2006
18 Citations (Scopus)

Effects of patient and surgical alignment variables on kinematics in TKR simulation under force-control

Haider, H., Walker, P., DesJardins, J. & Blunn, G., Nov 1 2006, In : Journal of ASTM International. 3, 10

Research output: Contribution to journalArticle

Knee prostheses
Posterior Cruciate Ligament
Knee Replacement Arthroplasties
Ligaments
Force control
2 Citations (Scopus)

Novel engineered nanocrystalline ultra-hydrophilic hard ceramic coatings for attachment and growth of bone marrow stromal cells

Namavar, F., Jackson, J. D., Sharp, J. G., Varma, S., Haider, H., Feschuk, C. & Garvin, K. L., Dec 1 2006, In : MCB Molecular and Cellular Biomechanics. 3, 4, p. 171-172 2 p.

Research output: Contribution to journalArticle

Atomic Force Microscopy
Hardness
Ceramics
Titanium
Aluminum
2 Citations (Scopus)

Searching for smart durable coatings to promote bone marrow stromal cell growth while preventing biofilm formation

Namavar, F., Jackson, J. D., Sharp, J. G., Mann, E. E., Bayles, K. W., Cheung, C. L. B., Feschuk, C. A., Varma, S., Haider, H. & Garvin, K. L., Dec 1 2006, Biofilm-Material Interactions: New Tools, Technologies and Opportunities. p. 1-7 7 p. (Materials Research Society Symposium Proceedings; vol. 954).

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Biofilms
Cell growth
Bone
Coatings
Ceramic coatings
2005
36 Citations (Scopus)

Measurements of constraint of total knee replacement

Haider, H. & Walker, P. S., Feb 1 2005, In : Journal of Biomechanics. 38, 2, p. 341-348 8 p.

Research output: Contribution to journalArticle

Knee prostheses
Knee Replacement Arthroplasties
Torque
Knee Joint
Knee
223 Citations (Scopus)

On Low-frequency electric power generation with PZT ceramics

Platt, S. R., Farritor, S. M. & Haider, H., Apr 1 2005, In : IEEE/ASME Transactions on Mechatronics. 10, 2, p. 240-252 13 p.

Research output: Contribution to journalArticle

Electric power generation
MEMS
Knee prostheses
Piezoelectric materials
Sensors
156 Citations (Scopus)

The use of piezoelectric ceramics for electric power generation within orthopedic implants

Platt, S. R., Farritor, S. M., Garvin, K. L. & Haider, H., Aug 1 2005, In : IEEE/ASME Transactions on Mechatronics. 10, 4, p. 455-461 7 p.

Research output: Contribution to journalArticle

Electric power generation
Piezoelectric ceramics
Orthopedics
Microprocessor chips
Sensors
2003
23 Citations (Scopus)

Characterizing the motion of total knee replacements in laboratory tests

Walker, P. S. & Haider, H., May 1 2003, In : Clinical Orthopaedics and Related Research. 410, p. 54-68 15 p.

Research output: Contribution to journalArticle

Knee Replacement Arthroplasties
Biomechanical Phenomena
Knee
Ligaments
Bone and Bones
31 Citations (Scopus)

Measurements of the level of surgical expertise using flight path analysis from da Vinci™ robotic surgical system

Verner, L., Oleynikov, D., Holtmann, S., Haider, H. & Zhukov, L., Jan 1 2003, Medicine Meets Virtual Reality 11 - NextMed: Health Horizon. IOS Press, p. 373-378 6 p. (Studies in Health Technology and Informatics; vol. 94).

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Flight paths
Robotics
End effectors
Statistical methods
Statistical Data Interpretation
2000
70 Citations (Scopus)

Methodology for long-term wear testing of total knee replacements

Walker, P. S., Blunn, G. W., Perry, J. P., Bell, C. J., Sathasivam, S., Andriacchi, T. P., Paul, J. P., Haider, H. & Campbell, P. A., Jan 1 2000, In : Clinical Orthopaedics and Related Research. 372, p. 290-301 12 p.

Research output: Contribution to journalArticle

Knee Replacement Arthroplasties
Knee
Plastics
Torque
Gait
89 Citations (Scopus)

The use of a force-controlled dynamic knee simulator to quantify the mechanical performance of total knee replacement designs during functional activity

Desjardins, J. D., Walker, P. S., Haider, H. & Perry, J., Oct 1 2000, In : Journal of Biomechanics. 33, 10, p. 1231-1242 12 p.

Research output: Contribution to journalArticle

Knee prostheses
Knee Replacement Arthroplasties
Knee
Simulators
Biomechanical Phenomena
1999
23 Citations (Scopus)

Evaluation of a testing method for the fatigue performance of total knee tibial trays

Ahir, S. P., Blunn, G. W., Haider, H. & Walker, P. S., Oct 1 1999, In : Journal of Biomechanics. 32, 10, p. 1049-1057 9 p.

Research output: Contribution to journalArticle

Fatigue
Knee
Biomechanical Phenomena
Fatigue of materials
Finite Element Analysis
1998

In kneed of testing

Ahir, S. P., Blunn, G. W., Haider, H., Walker, P. S., Browne, M. & Gregson, P. J., Dec 1 1998, In : Materials World. 6, 12, p. 746-748 3 p.

Research output: Contribution to journalArticle

Testing
Loads (forces)
Kinematics
Finite element method
1995
239 Citations (Scopus)

A theoretical and experimental study of a small-scale steam jet refrigerator

Eames, I. W., Aphornratana, S. & Haider, H., Jul 1995, In : International Journal of Refrigeration. 18, 6, p. 378-386 9 p.

Research output: Contribution to journalArticle

refrigerators
Refrigerators
Steam
steam
Theoretical Models

Integration of autocad with laser doppler anemometry (LDA)

Kamala, M. A., Boucher, R. F. & Haider, H., Dec 1 1995, p. 341-346. 6 p.

Research output: Contribution to conferencePaper

Lasers
Computer aided design
Flow fields
Hardware
Flow measurement
18 Citations (Scopus)

Transmission line modelling of simulated drill strings undergoing water-hammer

Beck, S. M., Haider, H. & Boucher, R. F., Nov 1995, In : Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science. 209, 6, p. 419-427 9 p.

Research output: Contribution to journalReview article

Drill strings
Water hammer
Electric lines
Pipe
Fluidics